Minimally invasive fixation of type B and C interprosthetic femoral fractures

被引:25
作者
Ehlinger, M. [1 ]
Czekaj, J. [1 ]
Adam, P. [1 ]
Brinkert, D. [1 ]
Ducrot, G. [1 ]
Bonnomet, F. [1 ]
机构
[1] De Hautepierre Hosp, Strasbourg Univ Hosp Grp, Dept Orthopaed & Trauma Surg, F-67098 Strasbourg, France
关键词
Femoral fracture; Interprosthetic fracture; Periprosthetic fracture; Internal fixation; Locked-plate; Minimally invasive; FEMUR FRACTURES; STABILIZATION SYSTEM; PLATE;
D O I
10.1016/j.otsr.2013.01.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Interprosthetic femoral fractures are rare and raise unresolved treatment issues such as the length of the fixation material that best prevents secondary fractures. Awareness of the advantages of locked-plate fixation via a minimally invasive approach remains limited, despite the potential of this method for improving success rates. Hypothesis: Femur-spanning (from the trochanters to the condyles) locked-plate fixation via a minimally invasive approach provides high healing rates with no secondary fractures. Materials and methods: From January 2004 to May 2011, all eight patients seen for interprosthetic fractures were treated with minimally invasive locked-plate fixation. Mean time since hip arthroplasty was 47.5 months and mean time since knee arthroplasty was 72.6 months. There were 12 standard primary prostheses and four revision prostheses; 11 prostheses were cemented and a single prosthesis showed femoral loosening. Classification about the hip prostheses was Vancouver B in one patient and Vancouver C in seven patients; about the knee prosthesis, the fracture was SoFCOT B in three patients and SOFCOT C in five patients, and a single fracture was SoFCOT D. Minimally invasive locking-plate fixation was performed in all eight patients, with installation on a traction table in seven patients. Results: Healing was obtained in all eight patients, after a mean of 14 weeks (range, 12-16 weeks). One patient had malalignment with more than 5 of varus. There were no general or infectious complications. One patient died, 32 months after surgery. The mean Parker-Palmer mobility score decreased from 6.2 pre-operatively to 2.5 at last follow-up. Early construct failure after 3 weeks in one patient required surgical revision. There was no change in implant fixation at last follow-up. No secondary fractures were recorded. Discussion: In patients with type B or C interprosthetic fractures, femur-spanning fixation not only avoids complications related to altered bone stock and presence of prosthetic material, but also decreases the risk of secondary fractures by eliminating stress riser zones. The minimally invasive option enhances heating by preserving the fracture haematoma. Thus, healing was obtained consistently in our patients, with no secondary fractures, although the construct failed in one patient. Level of evidence: Level IV. (C) 2013 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:563 / 569
页数:7
相关论文
共 28 条
[1]  
BEGUE T, 2006, REV CHIR ORTHOP S, V92, pS29
[2]   Mortality after periprosthetic fracture of the femur [J].
Bhattacharyya, Timothy ;
Chang, Denis ;
Meigs, James B. ;
Estok, Daniel M., II ;
Malchau, Henrik .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (12) :2658-2662
[3]  
Duncan CP, 1995, AAOS INSTR COURS LEC, V44, P293
[4]   Treatment of femoral fracture on previous implants with minimally-invasive surgery and total weight-bearing: Benefit of locking plate. Preliminary report [J].
Ehlinger, M. ;
Cognet, J. -M. ;
Simon, P. .
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2008, 94 (01) :26-36
[5]   Periprosthetic femoral fractures: The minimally invasive fixation option [J].
Ehlinger, M. ;
Bonnomet, F. ;
Adam, P. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (03) :304-309
[6]  
Ehlinger M, 2010, ORTHOP TRAUMATOL-SUR, V96, P43, DOI [10.1016/j.rcot.2009.11.002, 10.1016/j.otsr.2009.09.012]
[7]   Treatment of periprosthetic femoral fractures of the knee [J].
Ehlinger, Matthieu ;
Adam, Philippe ;
Abane, Lamine ;
Rahme, Michel ;
Moor, Beat Kaspar ;
Arlettaz, Yvan ;
Bonnomet, Francois .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (09) :1473-1478
[8]   Minimally invasive plate osteosynthesis: Does percutaneous plating disrupt femoral blood supply less than the traditional technique? [J].
Farouk, O ;
Krettek, C ;
Miclau, T ;
Schandelmaier, P ;
Guy, P ;
Tscherne, H .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (06) :401-406
[9]   Management of periprosthetic femur fractures with a first generation locking plate [J].
Fulkerson, Eric ;
Tejwani, Nirmal ;
Stuchin, Steven ;
Egol, Kenneth .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (08) :965-972
[10]   Treatment of Interprosthetic Fractures of the Femur [J].
Hou, Zhiyong ;
Moore, Blake ;
Bowen, Thomas R. ;
Irgit, Kaan ;
Matzko, Michelle E. ;
Strohecker, Kent A. ;
Smith, Wade R. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 71 (06) :1715-1719