En face parametric imaging of tissue birefringence using polarization-sensitive optical coherence tomography

被引:28
作者
Chin, Lixin [1 ]
Yang, Xiaojie [1 ]
McLaughlin, Robert A. [1 ]
Noble, Peter B. [2 ,3 ]
Sampson, David D. [1 ,4 ]
机构
[1] Univ Western Australia, Sch Elect Elect & Comp Engn, Opt Biomed Engn Lab, Crawley, WA 6009, Australia
[2] Univ Western Australia, Sch Anat Physiol & Human Biol, Crawley, WA 6009, Australia
[3] Univ Western Australia, Sch Paediat & Child Hlth, Ctr Neonatal Res & Educ, Crawley, WA 6009, Australia
[4] Univ Western Australia, Ctr Microscopy Characterisat & Anal, Crawley, WA 6009, Australia
基金
澳大利亚国家健康与医学研究理事会;
关键词
tissue birefringence; parametric imaging; polarization; optical coherence tomography; MAINTAINING FIBER; NEEDLE; COLLAGEN; SAMPLES; OCT;
D O I
10.1117/1.JBO.18.6.066005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A technique for generating en face parametric images of tissue birefringence from scans acquired using a fiber-based polarization-sensitive optical coherence tomography (PS-OCT) system utilizing only a single-incident polarization state is presented. The value of birefringence is calculated for each A-scan in the PS-OCT volume using a quadrature demodulation and phase unwrapping algorithm. The algorithm additionally uses weighted spatial averaging and weighted least squares regression to account for the variation in phase accuracies due to varying OCT signal-to-noise-ratio. The utility of this technique is demonstrated using a model of thermally induced damage in porcine tendon and validated against histology. The resulting en face images of tissue birefringence are more useful than conventional PS-OCT B-scans in assessing the severity of tissue damage and in localizing the spatial extent of damage. (C) 2013 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:5
相关论文
共 33 条
[1]   Swept-source polarization-sensitive optical coherence tomography based on polarization-maintaining fiber [J].
Al-Qaisi, Muhammad K. ;
Akkin, Taner .
OPTICS EXPRESS, 2010, 18 (04) :3392-3403
[2]  
[Anonymous], 2007, NUMERICAL RECIPES
[3]   Review of polarization sensitive optical coherence tomography and Stokes vector determination [J].
de Boer, JF ;
Milner, TE .
JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (03) :359-371
[4]   Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography [J].
deBoer, JF ;
Milner, TE ;
vanGemert, MJC ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (12) :934-936
[5]   Mapping local retardance in birefringent samples using polarization sensitive optical coherence tomography [J].
Fan, Chuanmao ;
Yao, Gang .
OPTICS LETTERS, 2012, 37 (09) :1415-1417
[6]   Tissue polarimetry: concepts, challenges, applications, and outlook [J].
Ghosh, Nirmalya ;
Vitkin, I. Alex .
JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (11)
[7]   Assessment of coronary plaque collagen with polarization sensitive optical coherence tomography (PS-OCT) [J].
Giattina, SD ;
Courtney, BK ;
Herz, PR ;
Harman, M ;
Shortkroff, S ;
Stamper, DL ;
Liu, B ;
Fujimoto, JG ;
Brezinski, ME .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 107 (03) :400-409
[8]   Polarization maintaining fiber based ultra-high resolution spectral domain polarization sensitive optical coherence tomography [J].
Goetzinger, Erich ;
Baumann, Bernhard ;
Pircher, Michael ;
Hitzenberger, Christoph K. .
OPTICS EXPRESS, 2009, 17 (25) :22704-22717
[9]   Extracting structural features of rat sciatic nerve using polarization-sensitive spectral domain optical coherence tomography [J].
Islam, M. Shahidul ;
Oliveira, Michael C. ;
Wang, Yan ;
Henry, Francis P. ;
Randolph, Mark A. ;
Park, B. Hyle ;
de Boer, Johannes F. .
JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (05)
[10]   Jones-matrix imaging of biological tissues with quadruple-channel optical coherence tomography [J].
Jiao, SL ;
Wang, LHV .
JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (03) :350-358