Migrating the Mach-Zehnder chemical and bio-sensor to the mid-infrared region

被引:5
作者
Leidner, L. [1 ]
Ewald, M. [1 ]
Sieger, M.
Mizaikoff, B.
Gauglitz, G. [1 ]
机构
[1] Univ Tubingen, Inst Phys & Theoret Chem, D-72076 Tubingen, Germany
来源
OPTICAL SENSORS 2013 | 2013年 / 8774卷
关键词
Mach-Zehnder interferometer; mid-infrared; gold nanoparticles; molecular recognition elements; biosensor; PHASE MODULATION;
D O I
10.1117/12.2017387
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The properties of integrated optical phase-modulated Mach-Zehnder interferometers (IO-MZI) are used to set up a new generation of chemical and biochemical sensors working in the mid-infrared. First applications of the MZI principle were introduced in the beginning 1990s. They range from a gas sensor to monitor organic solvent concentrations(1) to setting up an immunoassay for the detection of the herbicide simazine(2). Most if not all sensors of MZI type operate at wavelengths of the visible or near infrared spectrum. There are several reasons to change this strategy and move into the mid-infrared spectral range (MIR): higher manufacturing tolerances, increased evanescent field penetration depth, signal amplification by surface enhanced infrared absorption effect (SEIRA), species identification by MIR fingerprints. The basis of the planned MIR-MZI is a GaAs waveguide pattern epitaxially grown on a substrate(3). As a first step towards nanostructuring the waveguide surface, chemical deposition of Au nanoparticles on GaAs transducers was established. For the use of MIR-MZI sensors in bioanalytical assay development, chemical immobilization of molecular recognition elements on GaAs transducers was carried out. The modified surfaces were characterized by atomic force microscopy (AFM), dark field microscopy, contact angle measurements and ellipsometric data as well as by a modified version of Reflectometric Interference Spectroscopy (RIfS)(4). It was possible to monitor both the immobilization of gold nanoparticles and time-resolved specific binding using a model antibody antigen assay. After successful setup of relevant assays with RIfS, e. g. the detection of bacteria or endocrine disruptors, the assays are designed to be transferred onto the mid-infrared Mach-Zehnder interferometer.
引用
收藏
页数:15
相关论文
共 21 条
[1]   Stable surface coating of gallium arsenide with octadecylthiol monolayers [J].
Adlkofer, K ;
Tanaka, M .
LANGMUIR, 2001, 17 (14) :4267-4273
[2]  
BRECHT A, 1992, ANALUSIS, V20, P135
[3]   All-optical phase modulation for integrated interferometric biosensors [J].
Dante, Stefania ;
Duval, Daphne ;
Sepulveda, Borja ;
Belen Gonzalez-Guerrero, Ana ;
Ramon Sendra, Jose ;
Lechuga, Laura M. .
OPTICS EXPRESS, 2012, 20 (07) :7195-7205
[4]   Integrated optical Mach-Zehnder interferometers as simazine immunoprobes [J].
Drapp, B ;
Piehler, J ;
Brecht, A ;
Gauglitz, G ;
Luff, BJ ;
Wilkinson, JS ;
Ingenhoff, J .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 39 (1-3) :277-282
[5]  
ENGVALL E, 1972, J IMMUNOL, V109, P129
[6]   A GAS SENSOR BASED ON AN INTEGRATED OPTICAL MACH-ZEHNDER INTERFEROMETER [J].
FABRICIUS, N ;
GAUGLITZ, G ;
INGENHOFF, J .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 7 (1-3) :672-676
[7]   Multiple reflectance interference spectroscopy measurements made in parallel for binding studies [J].
Gauglitz, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (06)
[8]   Direct optical sensors: principles and selected applications [J].
Gauglitz, G .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (01) :141-155
[9]   Remote opto-chemical sensing with extreme sensitivity: design, fabrication and performance of a pigtailed integrated optical phase-modulated Mach-Zehnder interferometer system [J].
Heideman, RG ;
Lambeck, PV .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 61 (1-3) :100-127
[10]  
Hermanson G., 1996, BIOCONJUGATE TECHNIQ, DOI citeulike-article-id:3957756