Zn-Mn-Doped Mesoporous Bioactive Glass Nanoparticle-Loaded Zein Coatings for Bioactive and Antibacterial Orthopedic Implants

被引:33
作者
Batool, Syeda Ammara [1 ]
Ahmad, Khalil [1 ]
Irfan, Muhammad [2 ]
Rehman, Muhammad Atiq Ur [1 ]
机构
[1] Inst Space Technol Islamabad, Dept Mat Sci & Engn, Islamabad 44000, Pakistan
[2] Natl Univ Sci & Technol NUST H12, Sch Chem & Mat Engn SCME, Islamabad 44000, Pakistan
关键词
electrophoretic deposition; mesoporous bioactive glass nanoparticles; adhesion; antibacterial; bioactive; ELECTROPHORETIC DEPOSITION; COMPOSITE COATINGS; STAINLESS-STEEL; SURFACE MODIFICATION; BONE; DESIGN; AG; FABRICATION; KINETICS; BEHAVIOR;
D O I
10.3390/jfb13030097
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In recent years, natural polymers have replaced synthetic polymers for antibacterial orthopedic applications owing to their excellent biocompatibility and biodegradability. Zein is a biopolymer found in corn. The lacking mechanical stability of zein is overcome by incorporating bioceramics, e.g., mesoporous bioactive glass nanoparticles (MBGNs). In the present study, pure zein and zein/Zn-Mn MBGN composite coatings were deposited via electrophoretic deposition (EPD) on 316L stainless steel (SS). Zn and Mn were co-doped in MBGNs in order to make use of their antibacterial and osteogenic potential, respectively. A Taguchi design of experiment (DoE) study was established to evaluate the effect of various working parameters on the morphology of the coatings. It was observed that coatings deposited at 20 V for 5 min with 4 g/L concentration (conc.) of Zn-Mn MBGNs showed the highest deposition yield. Uniform coatings with highly dispersed MBGNs were obtained adopting these optimized parameters. Scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR) were employed to investigate the morphology and elemental composition of zein/Zn-Mn MBGN composite coatings. Surface properties, i.e., coating roughness and wettability analysis, concluded that composite coatings were appropriate for cell attachment and proliferation. For adhesion strength, various techniques, including a tape test, bend test, pencil hardness test, and tensile test, were performed. Wear and corrosion analysis highlighted the mechanical and chemical stability of the coatings. The colony forming unit (CFU) test showed that the zein/Zn-Mn MBGN composite coating was highly effective against Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli) due to the presence of Zn. The formation of a hydroxyapatite (HA)-like structure upon immersion in the simulated body fluid (SBF) validated the in vitro bioactivity of the coating. Moreover, a WST-8 assay depicted that the MG-63 cells proliferate on the composite coating. It was concluded that the zein/Zn-Mn MBGN coating synthesized in this work can be used for bioactive and antibacterial orthopedic applications.
引用
收藏
页数:24
相关论文
共 72 条
[1]   Integration of Mesoporous Bioactive Glass Nanoparticles and Curcumin into PHBV Microspheres as Biocompatible Composite for Drug Delivery Applications [J].
Aguilar-Rabiela, Arturo E. ;
Leal-Egana, Aldo ;
Nawaz, Qaisar ;
Boccaccini, Aldo R. .
MOLECULES, 2021, 26 (11)
[2]  
Ahmed Y., 2020, BIOMED APPL, V5, P237
[3]   Improvement in the surface properties of stainless steel via zein/hydroxyapatite composite coatings for biomedical applications [J].
Ahmed, Yusra ;
Rehman, Muhammad Atiq Ur .
SURFACES AND INTERFACES, 2020, 20
[4]   Best marketing strategy selection using fractional factorial design with analytic hierarchy process [J].
Al-Dawalibi, Anas ;
Al-Dali, Ibrahim H. ;
Alkhayyal, Bandar A. .
METHODSX, 2020, 7
[5]  
Ali S, 2014, MACROMOL RES, V22, P971
[6]  
[Anonymous], 2017, D335917 ASTM INT
[7]  
[Anonymous], 2020, ASTM D3363-20
[8]  
[Anonymous], 2008, B571972008E1 ASTM IN
[9]  
[Anonymous], 2017, D454117 ASTM
[10]   Ag-Sr doped mesoporous bioactive glass nanoparticles loaded chitosan/gelatin coating for orthopedic implants [J].
Aqib, Raja ;
Kiani, Sarang ;
Bano, Shaher ;
Wadood, Abdul ;
Rehman, Muhammad Atiq Ur .
INTERNATIONAL JOURNAL OF APPLIED CERAMIC TECHNOLOGY, 2021, 18 (03) :544-562