Quantitative assessment of renal obstruction in multi-phase CTU using automatic 3D segmentation of the renal parenchyma and renal pelvis: A proof of concept

被引:1
作者
Kahn, Chanoch [1 ]
Leichter, Isaac [1 ,2 ]
Lederman, Richard [2 ]
Sosna, Jacob [2 ]
Duvdevani, Mordechai [3 ]
Yeshua, Talia [1 ,4 ]
机构
[1] Jerusalem Collage Technol, Dept Appl Phys, 21 HaVaad HaLeumi St, Jerusalem, Israel
[2] Hadassah Med Ctr, Dept Radiol, 1 Kalman Man St, Jerusalem, Israel
[3] Hadassah Med Ctr, Dept Urol, 1 Kalman Man St, Jerusalem, Israel
[4] Jerusalem Coll Technol, Appl Phys Dept, 21 HaVaad HaLeumi St, IL-91160 Jerusalem, Israel
关键词
CT urography; 3D kidney segmentation; Renal obstruction; Urine drainage rate; KIDNEY; UROGRAPHY; MDCT; GUIDELINE; IMAGES;
D O I
10.1016/j.ejro.2022.100458
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Quantitative evaluation of renal obstruction is crucial for preventing renal atrophy. This study presents a novel method for diagnosing renal obstruction by automatically extracting objective indicators from routine multi-phase CT Urography (CTU). Material and methods: The study included multi-phase CTU examinations of 6 hydronephrotic kidneys and 24 non-hydronephrotic kidneys (23,164 slices). The developed algorithm segmented the renal parenchyma and the renal pelvis of each kidney in each CTU slice. Following a 3D reconstruction of the parenchyma and renal pelvis, the algorithm evaluated the amount of the contrast media in both components in each phase. Finally, the algorithm evaluated two indicators for assessing renal obstruction: the change in the total amount of contrast media in both components during the CTU phases, and the drainage time, "T1/2", from the renal parenchyma. Results: The algorithm segmented the parenchyma and renal pelvis with an average dice coefficient of 0.97 and 0.92 respectively. In all the hydronephrotic kidneys the total amount of contrast media did not decrease during the CTU examination and the T1/2 value was longer than 20 min. Both indicators yielded a statistically significant difference (p < 0.001) between hydronephrotic and normal kidneys, and combining both indicators yielded 100% accuracy. Conclusions: The novel algorithm enables accurate 3D segmentation of the renal parenchyma and pelvis and estimates the amount of contrast media in multi-phase CTU examinations. This serves as a proof-of-concept for the ability to extract from routine CTU indicators that alert to the presence of renal obstruction and estimate its severity.
引用
收藏
页数:11
相关论文
共 47 条
[1]   Update on MR urography (MRU): technique and clinical applications [J].
Abreu-Gomez, Jorge ;
Udare, Amar ;
Shanbhogue, Krishna P. ;
Schieda, Nicola .
ABDOMINAL RADIOLOGY, 2019, 44 (12) :3800-3810
[2]   SLIC Superpixels Compared to State-of-the-Art Superpixel Methods [J].
Achanta, Radhakrishna ;
Shaji, Appu ;
Smith, Kevin ;
Lucchi, Aurelien ;
Fua, Pascal ;
Suesstrunk, Sabine .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2012, 34 (11) :2274-2281
[3]   Differentiating Renal Neoplasms From Simple Cysts on Contrast-Enhanced CT on the Basis of Attenuation and Homogeneity [J].
Agochukwu, Nnenaya ;
Huber, Steffen ;
Spektor, Michael ;
Goehler, Alexander ;
Israel, Gary M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (04) :801-804
[4]  
[Anonymous], Black in Place
[5]   The perirenal space: Relationship of pathologic processes to normal retroperitoneal anatomy [J].
Bechtold, RE ;
Dyer, RB ;
Zagoria, RJ ;
Chen, MYM .
RADIOGRAPHICS, 1996, 16 (04) :841-854
[7]   3D Segmentation Algorithms for Computerized Tomographic Imaging: a Systematic Literature Review [J].
Carvalho, L. E. ;
Sobieranski, A. C. ;
von Wangenheim, A. .
JOURNAL OF DIGITAL IMAGING, 2018, 31 (06) :799-850
[8]   A Clinical View of Simple and Complex Renal Cysts [J].
Eknoyan, Garabed .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2009, 20 (09) :1874-1876
[9]   KIDNEY DIMENSIONS AT SONOGRAPHY - CORRELATION WITH AGE, SEX, AND HABITUS IN 665 ADULT VOLUNTEERS [J].
EMAMIAN, SA ;
NIELSEN, MB ;
PEDERSEN, JF ;
YTTE, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (01) :83-86
[10]  
Esteves Fabio P, 2006, AJR Am J Roentgenol, V187, pW610, DOI 10.2214/AJR.05.1550