High-resolution, small animal radiation research platform with X-ray tomographic guidance capabilities

被引:309
作者
Wong, John [1 ]
Armour, Elwood [1 ]
Kazanzides, Peter [2 ]
Iordachita, Ulian [2 ]
Tryggestad, Erik [1 ]
Deng, Hua [1 ]
Matinfar, Mohammad [2 ]
Kennedy, Christopher [1 ]
Liu, Zejian [1 ]
Chan, Timothy [1 ]
Gray, Owen [2 ]
Verhaegen, Frank [3 ]
McNutt, Todd [1 ]
Ford, Eric [1 ]
DeWeese, Theodore L. [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD 21231 USA
[2] Johns Hopkins Univ, Dept Comp Sci, Whiting Sch Engn, Baltimore, MD 21218 USA
[3] McGill Univ, Dept Med Phys, Montreal, PQ, Canada
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2008年 / 71卷 / 05期
关键词
small animal; radiation research; focal laboratory irradiation;
D O I
10.1016/j.ijrobp.2008.04.025
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To demonstrate the computed tomography, conformal irradiation, and treatment planning capabilities of a small animal radiation research platform (SARRP). Methods and Materials: The SARRP uses a dual-focal spot, constant voltage X-ray source mounted on a gantry with a source-to-isocenter distance of 35 cm. Gantry rotation is limited to 120 degrees from vertical. X-rays of 80-100 kVp from the smaller 0.4-mm focal spot are used for imaging. Both 0.4-mm and 3.0-mm focal spots operate at 225 kVp for irradiation. Robotic translate/rotate stages are used to position the animal. Cone-beam computed tomography is achieved by rotating the horizontal animal between the stationary X-ray source and a flat-panel detector. The radiation beams range from 0.5 mm in diameter to 60 x 60 mm(2). Dosimetry is measured with radiochromic films. Monte Carlo dose calculations are used for treatment planning. The combination of gantry and robotic stage motions facilitate conformal irradiation. Results: The SARRP spans 3 ft x 4 ft x 6 ft (width x length x height). Depending on the filtration, the isocenter dose outputs at a 1-cm depth in water were 22-375 cGy/min from the smallest to the largest radiation fields. The 20-80% dose falloff spanned 0.16 mm. Cone-beam computed tomography with 0.6 x 0.6 x 0.6 mm(3) voxel resolution was acquired with a dose of <1 cGy. Treatment planning was performed at submillimeter resolution. Conclusion: The capability of the SARRP to deliver highly focal beams to multiple animal model systems provides new research opportunities that more realistically bridge laboratory research and clinical translation. (C) 2008 Elsevier Inc.
引用
收藏
页码:1591 / 1599
页数:9
相关论文
共 18 条
[1]   Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies [J].
Chiu-Tsao, ST ;
Ho, Y ;
Shankar, R ;
Wang, L ;
Harrison, LB .
MEDICAL PHYSICS, 2005, 32 (11) :3350-3354
[2]   Treatment planning for a small animal using Monte Carlo simulation [J].
Chow, James C. L. ;
Leung, Michael K. K. .
MEDICAL PHYSICS, 2007, 34 (12) :4810-4817
[3]   Hematopoietic progenitor stem cell homing in mice lethally irradiated with ionizing radiation at differing dose rates [J].
Collis, SJ ;
Neutzel, S ;
Thompson, TL ;
Swartz, MJ ;
Dillehay, LE ;
Collector, MI ;
Sharkis, SJ ;
DeWeese, TL .
RADIATION RESEARCH, 2004, 162 (01) :48-55
[4]   Enhanced radiation response through directed molecular targeting approaches [J].
Collis, SJ ;
DeWeese, TL .
CANCER AND METASTASIS REVIEWS, 2004, 23 (3-4) :277-292
[5]   The small-animal radiation research platform (SARRP): dosimetry of a focused lens system [J].
Deng, Hua ;
Kennedy, Christopher W. ;
Armour, Elwood ;
Tryggestad, Erik ;
Ford, Eric ;
McNutt, Todd ;
Jiang, Licai ;
Wong, John .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (10) :2729-2740
[6]   Use of the Leksell Gamma Knife for localized small field lens irradiation in rodents [J].
DesRosiers, C ;
Mendonca, MS ;
Tyree, C ;
Moskvin, V ;
Bank, M ;
Massaro, L ;
Bigsby, RM ;
Caperell-Grant, A ;
Valluri, S ;
Dynlacht, JR ;
Timmerman, R .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2003, 2 (05) :449-454
[7]   Precise radiochromic film dosimetry using a flat-bed document scanner [J].
Devic, S ;
Seuntjens, J ;
Sham, E ;
Podgorsak, EB ;
Schmidtlein, CR ;
Kirov, AS ;
Soares, CG .
MEDICAL PHYSICS, 2005, 32 (07) :2245-2253
[8]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[9]   Design and evaluation of a variable aperture collimator for conformal radiotherapy of small animals using a microCT scanner [J].
Graves, Edward E. ;
Zhou, Hu ;
Chatterjee, Raja ;
Keall, Paul J. ;
Gambhir, Sanjiv Sam ;
Contag, Christopher H. ;
Boyer, Arthur L. .
MEDICAL PHYSICS, 2007, 34 (11) :4359-4367
[10]   An image-guided irradiator for pre-clinical radiation therapy studies [J].
Jaffray, D. ;
Moseley, D. ;
Chow, J. ;
Kim, S. ;
Ansell, S. ;
Wilson, G. ;
Chiarot, C. .
MEDICAL PHYSICS, 2006, 33 (06) :2241-2241