New three-dimensional head-mounted display system, TMDU-S-3D system, for minimally invasive surgery application: Procedures for gasless single-port radical nephrectomy

被引:52
作者
Kihara, Kazunori [1 ,2 ]
Fujii, Yasuhisa
Masuda, Hitoshi
Saito, Kazutaka
Koga, Fumitaka
Matsuoka, Yoh
Numao, Noboru [2 ]
Kojima, Kazuyuki [2 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch, Dept Urol, Bunkyo Ku, Tokyo 1138519, Japan
[2] Tokyo Med & Dent Univ, Sch Med, Minimally Invas Med Res Ctr, Tokyo 1138519, Japan
关键词
gasless single-port surgery; radical nephrectomy; three-dimensional head-mounted display; three-dimensional high-definition endoscope; MINIMUM INCISION; UROLOGY;
D O I
10.1111/j.1442-2042.2012.03044.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
We present an application of a new three-dimensional head-mounted display system that combines a high-definition three-dimensional organic electroluminescent head-mounted display with a high-definition three-dimensional endoscope to minimally invasive surgery, using gasless single-port radical nephrectomy procedures as a model. This system presents the surgeon with a higher quality of magnified three-dimensional imagery in front of the eyes regardless of head position, and simultaneously allows direct vision by moving the angle of sight downward. It is also significantly less expensive than the current robotic surgery system. While carrying out gasless single-port radical nephrectomy, the system provided the surgeon with excellent three-dimensional imagery of the operative field, direct vision of the outside and inside of the patient, and depth perception and tactile feedback through the devices. All four nephrectomies were safely completed within the operative time, blood loss was within usual limits and there were no complications. The display was light enough to comfortably be worn for a long operative time. Our experiences show that the three-dimensional head-mounted display system might facilitate maneuverability and safety in minimally invasive procedures, without prohibitive cost, and thus might mitigate the drawbacks of other three-dimensional vision systems. Because of the potential benefits that this system offers, it deserves further refinements of its role in various minimally invasive surgeries.
引用
收藏
页码:886 / 889
页数:4
相关论文
共 9 条
[1]  
Bhayani Sam B, 2005, Rev Urol, V7, P211
[2]   Robotic surgery in urology:: fact or fantasy? [J].
Binder, J ;
Bräutigam, R ;
Jonas, D ;
Bentas, W .
BJU INTERNATIONAL, 2004, 94 (08) :1183-1187
[3]   Portless endoscopic radical nephrectomy via a single minimum incision in 80 patients [J].
Kihara, K ;
Kageyama, Y ;
Yano, M ;
Kobayashi, T ;
Kawakami, S ;
Fujii, Y ;
Masuda, H ;
Hyochi, N .
INTERNATIONAL JOURNAL OF UROLOGY, 2004, 11 (09) :714-720
[4]   GASLESS SINGLE PORT ACCESS RADICAL NEPHRECTOMY [J].
Kihara, K. ;
Kawakami, S. ;
Fujii, Y. ;
Masuda, H. ;
Koga, F. ;
Saito, K. .
EUROPEAN UROLOGY SUPPLEMENTS, 2009, 8 (04) :392-392
[5]  
Kihara K, 2012, EMERGING RES TREATME, P231
[6]   Gasless single-port access endoscopic surgery in urology: Minimum incision endoscopic surgery, MIES [J].
Kihara, Kazunori ;
Kawakami, Satoru ;
Fujii, Yasuhisa ;
Masuda, Hitoshi ;
Koga, Fumitaka .
INTERNATIONAL JOURNAL OF UROLOGY, 2009, 16 (10) :791-800
[7]   Evaluation of three different laparoscopic modalities: Robotics versus three-dimensional vision laparoscopy versus standard laparoscopy [J].
Lagrange, Chad A. ;
Clark, Curtis J. ;
Gerber, Eric W. ;
Strup, Stephen E. .
JOURNAL OF ENDOUROLOGY, 2008, 22 (03) :511-516
[8]  
Masuda H, 2011, HEMODIALYSIS DIFFERE, P31
[9]   ORGANIC ELECTROLUMINESCENT DIODES [J].
TANG, CW ;
VANSLYKE, SA .
APPLIED PHYSICS LETTERS, 1987, 51 (12) :913-915