Patellar height assessment in total knee arthroplasty: a new method

被引:27
作者
Caton, Jacques H. [1 ,2 ]
Prudhon, Jean Louis [3 ]
Aslanian, Thierry [4 ]
Verdier, Regis [4 ]
机构
[1] Clin Emilie Vialar, 116 Rue Antoine Charial, F-69003 Lyon, France
[2] 175 Rue Jacquard CS 50307, F-69727 Genay, France
[3] Clin Cedres, 21 Rue Albert Londres, F-38432 Echirolles, France
[4] Groupe Lepine, 175 Rue Jacquard,CS 50307, F-69727 Genay, France
关键词
Total knee arthroplasty; Patellar height; Patella infera; Patella baja; Patella alta; Reliability; RELIABILITY; INTEROBSERVER; RATIOS; BAJA;
D O I
10.1007/s00264-016-3256-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We described in 1981 a method to evaluate patellar height in normal and symptomatic knees on sagittal X-ray view. This index is a frequently used method, yet it is not suitable after a total knee arthroplasty (TKA). The original method measures the distance between the distal margin of the articular surface of the patella (point A) and the anterosuperior angle of the tibial plateau (point T), then the length of the patellar articular surface (AP). The index is AT/AP ratio (normal values range from 0.8 to 1.2). After TKA, the T landmark is no longer available, so we must define a new T' landmark. This point is situated at the intersection between the line perpendicular to the tibial posterior cortex elevated at the tip of the fibular head and the tibial anterior cortex. This remarkable landmark can be identified before and after TKA, with a new relative index AT'/AP ratio. This modified method allows the comparison of patella height before and after TKA. We have used this modified index with the collaboration of several authors during the testing of different models of TKA, with an accurate reproducibility. Repeatability (usually called intra-observer reliability) was good, with intra-class correlation coefficients (ICCs) between 0.58 and 0.75 among the observers. Reproducibility (usually called inter-observer reliability) was also considered as good, with ICC ranging from 0.64 to 0.72. Patella height measurement has to be assessed with the original method (AT/AP) to detect patella infera that could influence the surgical approach. The correlation between original and modified indexes has to be assessed. The modification of patella height after TKA could be evaluated through the modified index and compared with functional results.
引用
收藏
页码:2527 / 2531
页数:5
相关论文
共 23 条
  • [1] Aparicio G, 1999, J PEDIATR ORTHOP B, V8, P29
  • [2] NEW METHOD OF MEASURING PATELLAR HEIGHT
    BLACKBURNE, JS
    PEEL, TE
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1977, 59 (02): : 241 - 242
  • [3] Blumensaat DD C., 1938, Ergebnisse der Chirurgie und Orthopadie, P149, DOI DOI 10.1007/978-3-642-91089-0_3
  • [4] Boon-Itt SB, 1930, AM J ROENTGENOL RADI, V24, P389
  • [5] CATON J, 1982, REV CHIR ORTHOP, V68, P317
  • [6] Caton J, 1989, Acta Orthop Belg, V55, P385
  • [7] Caton J, 1977, RUPTURES SYSTEME EXT
  • [8] Caton J, 2008, 1 C ART FEM PAT LYON
  • [9] Patellar height abnormalities: Patella Alta - Patella Infera. Diagnosis and treatment
    Caton, Jacques
    [J]. E-MEMOIRES DE L ACADEMIE NATIONALE DE CHIRURGIE, 2008, 7 (01): : 33 - 39
  • [10] The management of patella infera in current practice
    Caton, Jacques H.
    [J]. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2010, 20 (05) : 365 - 371