Determination of tetracyclines with a modified beta-cyclodextrin based fluorosensor

被引:25
|
作者
Gong, ZL
Zhang, ZJ
机构
[1] SHAANXI NORMAL UNIV,DEPT CHEM,XIAN 710062,PEOPLES R CHINA
[2] NANJING UNIV,DEPT CHEM,NANJING 210093,PEOPLES R CHINA
基金
中国国家自然科学基金;
关键词
ethyl substituted beta-cyclodextrin; fluorosensor; tetracyclines;
D O I
10.1016/S0003-2670(97)00343-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ethyl substituted beta-cyclodextrin based fluorosensor was prepared for the determination of tetracyclines in clinial samples. The analytical performance characteristics of the proposed sensor for analysis of very low levels of tetracycline (TC), oxytetracycline and chlorotetracycline were as follows: the linear ranges were 9-800, 20-1000 and 25-1000 nM, respectively. The detection limits were 4.0, 7.5 and 9.0 nM. The relative standard deviation for 11 determinations of 1 mu M of each antibiotic was 1.1%. The proposed optosensor has a higher selectivity. Species existing in biological samples hardly interfered, and the main interferences were caused by some metal ions which can complex with TC and enhance its fluorescence. They could be masked by adding excess of EDTA. The recommended method has been successfully tested for determining tetracycline in clinical samples (urine and pharmaceutical preparations). (C) 1997 Elsevier Science B.V.
引用
收藏
页码:205 / 210
页数:6
相关论文
共 50 条
  • [1] Development of a modified beta-cyclodextrin based fluorosensor for dipyridamole
    Gong, ZL
    Zhang, ZJ
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (01): : 138 - 140
  • [2] Development of a modified beta-cyclodextrin based fluorosensor for dipyridamole
    Zhilong Gong
    Zhujun Zhang
    Fresenius' Journal of Analytical Chemistry, 1998, 360 : 138 - 140
  • [3] Determination of derivatives of phenol with a modified electrode containing beta-cyclodextrin
    Kim, SH
    Won, MS
    Shim, YB
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 1996, 17 (04) : 342 - 347
  • [4] Construction of beta-cyclodextrin modified holographic sensor for the determination of ibuprofen in plasma and urine
    Yu, Jing
    Gai, Zhengxiao
    Cheng, Jiayi
    Tian, Feng
    Wei, Wei
    Li, Yang
    Gao, Qingyu
    Zou, Chenyang
    Qian, Rumeng
    Sun, Zhaomei
    Song, Xinyue
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 385
  • [5] Carbon Potentiometric Sensors Modified with Beta-cyclodextrin as a Carrier for the Determination of Bisoprolol Fumarate
    Frag, Eman Yossri
    Mohamed, Manva ELbadry
    El-Boraey, Hanaa A.
    EL-Sanafery, Safa S.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (07): : 6603 - 6616
  • [6] MODIFIED BETA-CYCLODEXTRIN LORAZEPAM INCLUSION COMPLEXATION
    ELMAHROUK, GM
    ALANGARY, AA
    ALMESHAL, MA
    PHARMAZEUTISCHE INDUSTRIE, 1994, 56 (12): : 1080 - 1084
  • [7] Electrochemical Determination of Quercetin at beta-Cyclodextrin Modified Chemical Sensor: A Voltammetric Study
    Reddaiah, Kasetty
    Reddy, Tukiakula Madhusudana
    Raghu, Pamula
    Swamy, Bahaddurghatta E. Kumra
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (02): : 122 - 134
  • [8] Factors affecting the determination of beta-cyclodextrin by phenolphthalein spectrophotometry
    Zhou, JX
    Zhang, LT
    Corke, H
    Yang, LS
    ANALYTICAL LETTERS, 1996, 29 (07) : 1201 - 1213
  • [9] BIOTECHNOLOGY OF BETA-CYCLODEXTRIN
    VOKK, R
    MENERT, A
    SAAR, EK
    BIOTECH FORUM EUROPE, 1991, 8 (09): : 510 - 516
  • [10] PURIFICATION OF BETA-CYCLODEXTRIN
    SOPHIANOPOULOS, AJ
    WARNER, IM
    ANALYTICAL CHEMISTRY, 1992, 64 (21) : 2652 - 2654