Evaluation of dose prediction error and optimization convergence error in four-dimensional inverse planning of robotic stereotactic lung radiotherapy

被引:6
作者
Chan, Mark K. H. [1 ,2 ]
Kwong, Dora L. W. [3 ]
Tong, Anthony [4 ]
Tam, Eric [4 ]
Ng, Sherry C. Y. [3 ]
机构
[1] Univ Hong Kong, Dept Clin Oncol, Hong Kong, Hong Kong, Peoples R China
[2] Tuen Mun Hosp, Dept Clin Oncol, Hong Kong, Hong Kong, Peoples R China
[3] Queen Mary Hosp, Dept Clin Oncol, Hong Kong, Hong Kong, Peoples R China
[4] Theresa Po CyberKnife Ctr, Hong Kong, Hong Kong, Peoples R China
关键词
4D optimization; Monte Carlo dose calculation; CyberKnife; SBRT; STATISTICAL UNCERTAINTIES; RADIATION-THERAPY; BODY RADIOTHERAPY; MONTE; CANCER; IMRT; RADIOSURGERY; SIZE;
D O I
10.1120/jacmp.v14i4.4270
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Inverse optimization of robotic stereotactic lung radiotherapy is typically performed using relatively simple dose calculation algorithm on a single instance of breathing geometry. Variations of patient geometry and tissue density during respiration could reduce the dose accuracy of these 3D optimized plans. To quantify the potential benefits of direct four-dimensional (4D) optimization in robotic lung radiosurgery, 4D optimizations using 1) ray-tracing algorithm with equivalent path-length heterogeneity correction (4EPL(opt)), and 2) Monte Carlo (MC) algorithm (4MC(opt)), were performed in 25 patients. The 4EPL(opt) plans were recalculated using MC algorithm (4MC(recal)) to quantify the dose prediction errors (DPEs). Optimization convergence errors (OCEs) were evaluated by comparing the 4MC(recal) and 4MC(opt) dose results. The results were analyzed by dose-volume histogram indices for selected organs. Statistical equivalence tests were performed to determine the clinical significance of the DPEs and OCEs, compared with a 3% tolerance. Statistical equivalence tests indicated that the DPE and the OCE are significant predominately in GTV D-98%. The DPEs in V-20 of lung, and D-2% of cord, trachea, and esophagus are within 1.2%, while the OCEs are within 10.4% in lung V-20 and within 3.5% in trachea D2%. The marked DPE and OCE suggest that 4D MC optimization is important to improve the dosimetric accuracy in robotic-based stereotactic body radiotherapy, despite the longer computation time.
引用
收藏
页码:182 / 195
页数:14
相关论文
共 30 条
[1]   The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: Implications for tumour coverage [J].
Aarup, Lasse Rye ;
Nahum, Alan E. ;
Zacharatou, Christina ;
Juhler-Nottrup, Trine ;
Knoos, Tommy ;
Nystrom, Hakan ;
Specht, Lena ;
Wieslander, Elinore ;
Korreman, Stine S. .
RADIOTHERAPY AND ONCOLOGY, 2009, 91 (03) :405-414
[2]  
[Anonymous], 2010, J ICRU, DOI [10.1093/jicru_ndq002, DOI 10.1093/JICRU_NDQ002]
[3]   Direct aperture optimization for IMRT using Monte Carlo generated beamlets [J].
Bergman, Alanah M. ;
Bush, Karl ;
Milette, Marie-Pierre ;
Popescu, I. Antoniu ;
Otto, Karl ;
Duzenli, Cheryl .
MEDICAL PHYSICS, 2006, 33 (10) :3666-3679
[4]   Investigation of four-dimensional (4D) Monte Carlo dose calculation in real-time tumor tracking stereotatic body radiotherapy for lung cancers [J].
Chan, Mark K. H. ;
Kwong, Dora L. W. ;
Ng, Sherry C. Y. ;
Tam, Eric K. W. ;
Tong, Anthony S. M. .
MEDICAL PHYSICS, 2012, 39 (09) :5479-5487
[5]   Reporting and analyzing statistical uncertainties in Monte Carlo-based treatment planning [J].
Chetty, Indrin J. ;
Rosu, Mihaela ;
Kessler, Marc L. ;
Fraass, Benedick A. ;
Ten Haken, Randall K. ;
Kong, Feng-Ming ;
McShan, Daniel L. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (04) :1249-1259
[6]   Investigation of voxel warping and energy mapping approaches for fast 4D Monte Carlo dose calculations in deformed geometries using VMC++ [J].
Heath, Emily ;
Tessier, Frederic ;
Kawrakow, Iwan .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16) :5187-5202
[7]   Incorporating uncertainties in respiratory motion into 4D treatment plan optimization [J].
Heath, Emily ;
Unkelbach, Jan ;
Oelfke, Uwe .
MEDICAL PHYSICS, 2009, 36 (07) :3059-3071
[8]   The effect of statistical uncertainty on inverse treatment planning based on Monte Carlo dose calculation [J].
Jeraj, R ;
Keall, P .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (12) :3601-3613
[9]   Investigation of optimal beam margins for stereotactic radiotherapy of lung-cancer using Monte Carlo dose calculations [J].
Jin, L. ;
Wang, L. ;
Li, J. ;
Luo, W. ;
Feigenberg, S. J. ;
Ma, C-M .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (12) :3549-3561
[10]   The CyberKnife® Robotic Radiosurgery System in 2010 [J].
Kilby, W. ;
Dooley, J. R. ;
Kuduvalli, G. ;
Sayeh, S. ;
Maurer, C. R., Jr. .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2010, 9 (05) :433-452