Effect of regenerator on the direct steam generation solar power system characterized by prolonged thermal storage and stable power conversion

被引:7
作者
Li, Pengcheng [1 ,3 ]
Cao, Qing [4 ]
Li, Jing [2 ]
Wang, Yandong [5 ]
Pei, Gang [6 ]
Gao, Cai [1 ]
Zhao, Hongling [1 ]
Liu, Xunfen [1 ]
机构
[1] Hefei Univ Technol, Sch Automobile & Traff Engn, 193 Tunxi Rd, Hefei, Anhui, Peoples R China
[2] Univ Hull, Res Ctr Sustainable Energy Technol, Energy & Environm Inst, Kingston Upon Hull HU6 7RX, N Humberside, England
[3] Y&C ENGINE CO LTD, 2 Eqiao Rd, Sanshan, Wuhu, Peoples R China
[4] Hefei Univ Technol, Sch Mech Engn, 193 Tunxi Rd, Hefei, Anhui, Peoples R China
[5] Hefei Gen Machinery Res Inst, 888 Changjiang Rd, Hefei, Anhui, Peoples R China
[6] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, 96 Jinzhai Rd, Hefei, Anhui, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Regenerator; Direct steam generation; Heat exchanger area; Heat storage capacity; Net profit; ORGANIC RANKINE-CYCLE; INTERNAL HEAT-EXCHANGER; WORKING FLUIDS; TEMPERATURE; ORC; PERFORMANCE; ENERGY; OPTIMIZATION; DESIGN; CONDENSATION;
D O I
10.1016/j.renene.2020.06.037
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The direct steam generation (DSG) solar power system using two stage accumulators and cascade steam-organic Rankine cycle (RC-ORC) has remarkably enlarged storage capacity. It can facilitate stable power generation and address the challenges of conventional DSG systems. Regenerator is generally an issue worthy of discussion in organic Rankine cycle (ORC) systems. However, its influence on the newly proposed DSG system has not been investigated yet and is expected to be appreciable. Introducing a regenerator affects not only the ORC efficiency, RC-ORC efficiency, heat exchanger area, but also heat storage capacity, discharge duration, discharge efficiency, aperture area of collectors and the net profit (DP). Detailed performance comparison between the DSG systems without/with regenerator is carried out in this paper. The results indicate that at a given power output, aperture area is reduced by the regenerator especially for MM, R365mfc and pentane due to the increment in ORC, RC-ORC and discharge efficiencies, as well as the decrement in heat input. Discharge duration is shortened by 0.01-1.78 h depending on ORC fluids. R365mfc exhibits the maximum Delta P (4.19 similar to 6.48 million USD), followed by MM and pentane. On the contrary, Delta P is negative for benzene (-5.61 similar to 4.31 million USD). (c) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1099 / 1116
页数:18
相关论文
共 51 条
[1]  
Antonio Rovira, 2015, ENERGY, V89, P305
[2]   Proposal of a combined heat and power plant hybridized with regeneration organic Rankine cycle: Energy-Exergy evaluation [J].
Anvari, Simin ;
Jafarmadar, Samad ;
Khalilarya, Shahram .
ENERGY CONVERSION AND MANAGEMENT, 2016, 122 :357-365
[3]   Energy, economic and. environmental (3E) aspects of internal heat exchanger for ORC geothermal power plants [J].
Bina, Saeid Mohammadzadeh ;
Jalilinasrabady, Saeid ;
Fujii, Hikari .
ENERGY, 2017, 140 :1096-1106
[4]   Integrated thermoeconomic optimization of standard and regenerative ORC for different heat source types and capacities [J].
Braimakis, Konstantinos ;
Karellas, Sotirios .
ENERGY, 2017, 121 :570-598
[5]   Thermoeconomic analysis and off-design performance of an organic Rankine cycle powered by medium-temperature heat sources [J].
Calise, Francesco ;
Capuozzo, Claudio ;
Carotenuto, Alberto ;
Vanoli, Laura .
SOLAR ENERGY, 2014, 103 :595-609
[6]   Thermal energy storage for solar-powered organic Rankine cycle engines [J].
Casati, E. ;
Galli, A. ;
Colonna, P. .
SOLAR ENERGY, 2013, 96 :205-219
[7]   Fluid selection of Organic, Rankine Cycle for low-temperature waste heat recovery based on thermal optimization [J].
Cataldo, Filippo ;
Mastrullo, Rita ;
Mauro, Alfonso William ;
Vanoli, Giuseppe Peter .
ENERGY, 2014, 72 :159-167
[8]  
Duffie JA, 2013, SOLAR ENGINEERING OF THERMAL PROCESSES, 4TH EDITION, P1, DOI 10.1002/9781118671603
[9]   Experimental investigation of modern ORC working fluids R1224yd(Z) and R1233zd(E) as replacements for R245fa [J].
Eyerer, Sebastian ;
Dawo, Fabian ;
Kaindl, Johannes ;
Wieland, Christoph ;
Spliethoff, Hart-Mut .
APPLIED ENERGY, 2019, 240 :946-963
[10]   Experimental study of an ORC (Organic Rankine Cycle) and analysis of R1233zd-E as a drop-in replacement for R245fa for low temperature heat utilization [J].
Eyerer, Sebastian ;
Wieland, Christoph ;
Vandersickel, Annelies ;
Spliethoff, Hartmut .
ENERGY, 2016, 103 :660-671