Comparison between two- and three-dimensional ultrasound measurements of nuchal translucency

被引:17
作者
Clementschitsch, G [1 ]
Hasenöhrl, G [1 ]
Schaffer, H [1 ]
Steiner, H [1 ]
机构
[1] St Johannsspital Salzburg, Prenatal Diag & Therapy Unit, Dept Obstet & Gynecol, A-5020 Salzburg, Austria
关键词
nuchal translucency; prenatal diagnosis; three-dimensional ultrasound; ultrasound screening;
D O I
10.1046/j.0960-7692.2001.00566.x
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective Fetal nuchal translucency measurement has been introduced as a screening test for the calculation of risk of chromosomal abnormalities. The purpose of this study was to investigate. (1) the feasibility of obtaining nuchal translucency measurements using three-dimensional ultrasound; (2) whether three-dimensional ultrasound could improve and facilitate the required repeated measurements of nuchal translucency; (3) the correlation between two- and three-dimensional nuchal translucency measurement values. Subjects and methods Between September 1999 and May 2000, in a prospective cohort study, 229 unselected pregnant women with a mean age of 34.6 (range, 20-46) years were examined. The mean fetal crown-rump length was 64.3 (range, 45-84) mm. Nuchal translucency thickness was measured first by two- and then by three-dimensional ultrasound in two planes (three-dimensional mid-sagittal and three-dimensional transverse). An attempt was made to repeat each nuchal translucency measurement three ti. mes (totalling nine measurements per patient) and the means of the two- and three-dimensional measurements were compared. The majority (95%) of the measurements were made transabdominally and 5% were made transvaginally. The time limit for each examination was 20 min. Results With the two-dimensional method, nuchal translucency could be measured in 96.8% of cases. Of these, three measurements could be obtained in 51.7%, two in 23.2% and only one in 25.1%. The three-dimensional examination was successful in 98.6% of cases. Of these, three measurements could be obtained in 60%, two in 22.8% and one in 17.2%. Transvaginally, all examinations were successful. The main reason for the failure of two-dimensional ultrasound was the fetal position, which in some cases precluded the distinction between fetal skin and amnion or the uterine wall. Using two-dimensional ultrasound, 6.3% of the cases of measurement failure were due to an inability to differentiate clearly between fetal skin and amnion, whilst the equivalent value for the three-dimensional method was only 3.3%. For the three-dimensional technique, fetal movement was the main reason for failure. The mean time for both methods was similar (9 min and 10 min for two- and three-dimensional ultrasound, respectively) and the correlation between the measurements obtained by the two-and three-dimensional techniques was very high (r = 0.97). Conclusion The number of fetuses in which nuchal translucency could be measured tended to be higher with three-dimensional ultrasound, although the difference was not statistically significant. The possibility of rotating a stored volume and inspecting it in three orthogonal planes makes three-dimensional ultrasound a useful tool for nuchal translucency measurements, especially in doubtful cases.
引用
收藏
页码:475 / 480
页数:6
相关论文
共 24 条
[1]  
Bonilla-Musoles F, 1998, J ULTRAS MED, V17, P419
[2]  
BONILLAMUSOLES F, 1995, J ULTRAS MED, V14, P349
[3]  
Hafner E, 1998, PRENATAL DIAG, V18, P29, DOI 10.1002/(SICI)1097-0223(199801)18:1<29::AID-PD213>3.0.CO
[4]  
2-N
[5]   SCREENING FOR CHROMOSOMAL-ABNORMALITIES IN AN UNSELECTED POPULATION BY FETAL NUCHAL TRANSLUCENCY [J].
HAFNER, E ;
SCHUCHTER, K ;
PHILIPP, K .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1995, 6 (05) :330-333
[6]  
KORNMAN LH, 1997, PRENAT DIAGN, V17, P785
[7]   Three-dimensional transvaginal ultrasound improves measurement of nuchal translucency [J].
Kurjak, A ;
Kupesic, S ;
Ivancic-Kosuta, M .
JOURNAL OF PERINATAL MEDICINE, 1999, 27 (02) :97-102
[8]  
Maier B, 1998, 3 5 ULTRASOUND OBSTE, P149
[9]   Forty years of obstetric ultrasound 1957-1997: From a-scope to three dimensions [J].
McNay, MB ;
Fleming, JEE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (01) :3-56
[10]  
Merz E, 1999, GYNAKOLOGE, V32, P213