A quality improvement initiative to optimize use of a mechanical chest compression device within a high-performance CPR approach to out-of-hospital cardiac arrest resuscitation

被引:39
作者
Levy, Michael [1 ,2 ]
Yost, Dana [3 ,4 ]
Walker, Robert G. [5 ]
Scheunemann, Erich [1 ,2 ]
Mendive, Steve R. [1 ,2 ]
机构
[1] Anchorage Fire Dept, Anchorage, AK USA
[2] Univ Alaska Anchorage, Anchorage, AK USA
[3] Redmond Fire Dept, Redmond, WA USA
[4] Resurgent Biomed Consulting, Seattle, WA 98012 USA
[5] Physiocontrol Inc, Redmond, WA USA
关键词
High performance CPR; Mechanical chest compression; OHCA; Chest compression fraction; Cardiac arrest resuscitation; AMERICAN-HEART-ASSOCIATION; EMERGENCY CARDIOVASCULAR CARE; CARDIOPULMONARY-RESUSCITATION; RANDOMIZED-TRIAL; DEFIBRILLATION; INTERRUPTIONS; GUIDELINES; FRACTION;
D O I
10.1016/j.resuscitation.2015.04.005
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Minimizing the chest compression pause associated with application of a mechanical CPR device is a key component of optimal integration into the overall resuscitation process. As part of a multi-agency implementation project, Anchorage Fire Department deployed LUCAS CPR devices on BLS and ALS fire apparatus for initiation early in resuscitation efforts. A 2012 report identified the pause interval for device application as a key opportunity for quality improvement (QI). In early 2013 we began a QI initiative to reduce device application time interval and optimize the overall CPR process. To assess QI initiative effectiveness, we compared key CPR process metrics from before to during and after its implementation. Methods: We included all cases of EMS-treated out-of-hospital cardiac arrest during 2012 and 2013 in which a mechanical CPR device was used and the defibrillator electronic record was available. Continuous ECG and impedance data were analyzed to measure chest compression fraction, duration of the pause from last manual to first mechanical compression, and duration of the longest overall pause in the resuscitation effort. Results: Compared to cases from 2012 (n = 61), median duration of the pause prior to first mechanical compression for cases from 2013 (n = 71) decreased from 21(15, 31) to 7 (4, 12) s (p < 0.001), while median chest compression fraction increased from 0.90 (0.88, 0.93) to 0.95 (0.93, 0.96)(p < 0.001). Median duration of the longest pause decreased from 25 (20, 35) to 13 (10, 20) s (p < 0.001), while the proportion of cases where the longest pause was for mechanical CPR application decreased from 74% to 31% (p < 0.001). Conclusions: Our QI initiative substantially reduced the duration of the pause prior to first mechanical compression. Combined with the simultaneous significant increase in compression fraction and significant decrease in duration of the longest pause, this finding strongly suggests a large improvement in mechanical CPR device application efficiency within an overall high-performance CPR process. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:32 / 37
页数:6
相关论文
共 23 条
[1]   Part 5: Adult Basic Life Support 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care [J].
Berg, Robert A. ;
Hemphill, Robin ;
Abella, Benjamin S. ;
Aufderheide, Tom P. ;
Cave, Diana M. ;
Hazinski, Mary Fran ;
Lerner, E. Brooke ;
Rea, Thomas D. ;
Sayre, Michael R. ;
Swor, Robert A. .
CIRCULATION, 2010, 122 (18) :S685-S705
[2]   Part 7: CPR Techniques and Devices 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care [J].
Cave, Diana M. ;
Gazmuri, Raul J. ;
Otto, Charles W. ;
Nadkarni, Vinay M. ;
Cheng, Adam ;
Brooks, Steven C. ;
Daya, Mohamud ;
Sutton, Robert M. ;
Branson, Richard ;
Hazinski, Mary Fran .
CIRCULATION, 2010, 122 (18) :S720-S728
[3]   Compressions during defibrillator charging shortens shock pause duration and improves chest compression fraction during shockable out of hospital cardiac arrest [J].
Cheskes, Sheldon ;
Common, Matthew R. ;
Byers, P. Adam ;
Zhan, Cathy ;
Morrison, Laurie J. .
RESUSCITATION, 2014, 85 (08) :1007-1011
[4]   Chest Compression Fraction Determines Survival in Patients With Out-of-Hospital Ventricular Fibrillation [J].
Christenson, Jim ;
Andrusiek, Douglas ;
Everson-Stewart, Siobhan ;
Kudenchuk, Peter ;
Hostler, David ;
Powell, Judy ;
Callaway, Clifton W. ;
Bishop, Dan ;
Vaillancourt, Christian ;
Davis, Dan ;
Aufderheide, Tom P. ;
Idris, Ahamed ;
Stouffer, John A. ;
Stiell, Ian ;
Berg, Robert .
CIRCULATION, 2009, 120 (13) :1241-1247
[5]   Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest [J].
Edelson, Dana P. ;
Abella, Benjamin S. ;
Kramer-Johansen, Jo ;
Wik, Lars ;
Myklebust, Helge ;
Barry, Anne M. ;
Merchant, Raina M. ;
Vanden Hoek, Terry L. ;
Steen, Petter A. ;
Becker, Lance B. .
RESUSCITATION, 2006, 71 (02) :137-145
[6]   Effects of interrupting precordial compressions on the calculated probability of defibrillation success during out-of-hospital cardiac arrest [J].
Eftestol, T ;
Sunde, K ;
Steen, PA .
CIRCULATION, 2002, 105 (19) :2270-2273
[7]  
Eisenberg MickeyS., 2009, Resuscitate!: How Your Community Can Improve Survival from Sudden Cardiac Arrest
[8]  
Esibov A, 2014, PREHOSP EMERG CARE, V18, P124
[9]   Improved neurological outcome with continuous chest compressions compared with 30: 2 compressions-to-ventilations cardiopulmonary resuscitation in a realistic swine model of out-of-hospital cardiac arrest [J].
Ewy, Gordon A. ;
Zuercher, Mathias ;
Hilwig, Ronald W. ;
Sanders, Arthur B. ;
Berg, Robert A. ;
Otto, Charles W. ;
Hayes, Melinda M. ;
Kern, Karl B. .
CIRCULATION, 2007, 116 (22) :2525-2530
[10]   Manual chest compression vs use of an automated chest compression device during resuscitation following out-of-hospital cardiac arrest - A randomized trial [J].
Hallstrom, Al ;
Rea, Thomas D. ;
Sayre, Michael R. ;
Christenson, James ;
Anton, Andy R. ;
Mosesso, Vince N., Jr. ;
Van Ottingham, Lois ;
Olsufka, Michele ;
Pennington, Sarah ;
White, Lynn J. ;
Yahn, Stephen ;
Husar, James ;
Morris, Mary F. ;
Cobb, Leonard A. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (22) :2620-2628