Development and validation of a liquid chromatography coupled to tandem mass spectrometry method for the simultaneous quantification of five analgesics and sedatives, and six of their active metabolites in human plasma: Application to a clinical study on the determination of neurological death in the intensive care unit

被引:7
作者
Jutras, Martin [1 ]
Williamson, David [1 ,2 ,3 ]
Chasse, Michael [4 ,5 ,6 ]
Leclair, Gregoire [1 ]
机构
[1] Univ Montreal, Fac Pharm, Platform Biopharm, Pavillon Jean Coutu,2940 Chemin Polytech, Montreal, PQ H3T 1J4, Canada
[2] Hop Sacre Coeur Montreal, Res Ctr, Montreal, PQ H4J 1C5, Canada
[3] Hop Sacre Coeur Montreal, Pharm Dept, Montreal, PQ H4J 1C5, Canada
[4] Univ Montreal, Fac Med, Montreal, PQ H3T 1J4, Canada
[5] Ctr Hosp Univ Montreal, Res Ctr, Montreal, PQ H2X 0A9, Canada
[6] Ctr Hosp Univ Montreal, Dept Med Crit Care, Montreal, PQ H2X 0A9, Canada
关键词
Method validation; Liquid chromatography coupled to tandem mass spectrometry; Human plasma; Sedatives; Analgesics; Neurological death; SOLID-PHASE EXTRACTION; PROPOFOL; MIDAZOLAM; MORPHINE; FENTANYL; ASSAY; MORPHINE-6-BETA-GLUCURONIDE; MORPHINE-3-BETA-GLUCURONIDE; HYDROMORPHONE; NORFENTANYL;
D O I
10.1016/j.jpba.2020.113521
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and selective high-performance liquid chromatographic method coupled to tandem mass spectrometry was developed and validated for the quantification of morphine, hydromorphone, fentanyl, midazolam and propofol and their metabolites morphine-3-beta-D glucuronide, morphine- 6-beta-D glucuronide, hydromorphone 3-beta-D glucuronide, 1'-hydroxymidazolam-beta-D glucuronide, alpha-hydroxymidazolam and 4-hydroxymidazolam in human plasma using potassium oxalate/sodium fluoride mixture as anticoagulant. Human plasma samples (0.4 mL) to which were added a mixture of eleven deuterated internal standards were subjected to solid phase extraction using a mixed-mode polymeric Oasis PRiME MCX in 96-well format. Propofol was selectively eluted and further derivatized using 2-Fluoro-1-methylpyridinium p-toluenesulfonate, whereas the remaining 10 analytes were eluted separately and further concentrated. The derivatized propofol was analyzed separately in a second injection. The analytes were chromatographically separated on a Kinetex phenyl-hexyl analytical column in gradient elution mode, using a mobile phase consisting of aqueous ammonium formate/formic acid buffer and methanol. The overall run time was 8 min. Detection was performed using an AB/SCIEX 4000 QTRAP instrument with positive electrospray ionization employing scheduled multiple reaction monitoring mode. The lower limits of quantification ranged from 0.02 to 5 ng/mL depending on the analyte. Calibration curves covered a concentration range of 1000x in all cases but 1'-hydroxymidazolam-beta-D-glucuronide where it covered a range of 500 x . The validated method was accurate and precise, the intra-day accuracy and precision of quality control samples (4 concentration levels, n = 6 each) being within 91.5-112 % and 1.3-13.2 % (coefficient of variation), respectively, and inter-day (n = 24; 4 days) accuracy and precision of quality control samples (3 concentration levels) being within 94.8-103.5 % and 3.2-11.2 % (coefficient of variation). Mean absolute extraction recoveries were above 60 % for all compounds, except for hydromorphone 3-beta-D-glucuronide (44 %) and for 1'-hydroxymidazolam-beta-D-glucuronide (33 %). Internal standard corrected matrix effect ranged from -4.8 to 3.8 % in normal plasma and in plasma containing 1 % hemolyzed blood. Analytes were stable (above 90 %) in plasma and blood for 19 hat 22 degrees C, in blood for 90 hat 5 degrees C, in plasma for 60 days at -20 degrees C, for 4 months at -70 degrees C and after three freeze-thaw cycles, and in the injection solvent for at least 3 days in the autosampler. The present method is successfully being applied in a multicenter clinical study for the analysis of plasma samples from patients in intensive care units from a number of Canadian hospitals. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] A validated liquid chromatography tandem mass spectrometry method for simultaneous determination of pioglitazone, hydroxypioglitazone, and ketopioglitazone in human plasma and its application to a clinical study
    Kawaguchi-Suzuki, Marina
    Bril, Fernando
    Sanchez, Paola Portillo
    Cusi, Kenneth
    Frye, Reginald F.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 969 : 219 - 223
  • [22] Determination of atomoxetine metabolites in human plasma by liquid chromatography/tandem mass spectrometry and its application to a pharmacokinetic study
    Choi, Chang-Ik
    Bae, Jung-Woo
    Lee, Hye-In
    Jang, Choon-Gon
    Sohn, Uy Dong
    Lee, Seok-Yong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 885 : 103 - 108
  • [23] Simultaneous determination of rabeprazole and its two active metabolites in human urine by liquid chromatography with tandem mass spectrometry and its application in a urinary excretion study
    Simpemba, Ernest
    Liu, Ruijuan
    Sun, Chenglong
    Agbokponto, Janvier Engelbert
    Ding, Li
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (15) : 1951 - 1956
  • [24] Bioanalytical method development and validation of a liquid chromatography-tandem mass spectrometry method for determination of β-lapachone in human plasma
    Putnam, William C.
    Kallem, Raja Reddy
    Subramaniyan, Indhumathy
    Beg, M. Shaalan
    Edpuganti, Vindhya
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 188
  • [25] Simultaneous determination of flurbiprofen and its hydroxy metabolite in human plasma by liquid chromatography-tandem mass spectrometry for clinical application
    Lee, Hye-In
    Choi, Chang-Ik
    Byeon, Ji-Yeong
    Lee, Jung-Eun
    Park, So-Young
    Kim, Young-Hoon
    Kim, Se-Hyung
    Lee, Yun-Jeong
    Jang, Choon-Gon
    Lee, Seok-Yong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 971 : 58 - 63
  • [26] Liquid chromatography-tandem mass/mass spectrometry method for the quantification of rabeprazole in human plasma and application to a pharmacokinetic study
    Yu, Liyan
    Deng, Haishan
    Xiang, Bingren
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2010, 60 (05): : 262 - 266
  • [27] Development and validation of a rapid and sensitive liquid chromatography-tandem mass spectrometry method for benvitimod quantification in human plasma
    Zhao, Libo
    Zhu, Baoying
    Chen, Xin
    Chen, Genghui
    Chen, Haibo
    Li, Yuzhen
    Jing, Shan
    Fang, Yi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 885 : 160 - 165
  • [28] Simultaneous quantification of acetaminophen and five acetaminophen metabolites in human plasma and urine by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry: Method validation and application to a neonatal pharmacokinetic study
    Cook, Sarah F.
    King, Amber D.
    van den Anker, John N.
    Wilkins, Diana G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1007 : 30 - 42
  • [29] Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of zofenopril and its active metabolite zofenoprilat in human plasma
    Jiang, Yuan
    Yan, Fang
    Di, Bin
    Feng, Fang
    You, Linjun
    Huang, Lili
    Lu, Juan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (03) : 527 - 532
  • [30] Simultaneous determination of diquat, paraquat, glufosinate, and glyphosate in plasma by liquid chromatography/tandem mass spectrometry: from method development to clinical application
    Liu, Maozhu
    Fan, Fei
    Zhang, Jing
    Fang, Shiyong
    Bai, Yangjuan
    Li, Yamei
    Zou, Yuangao
    An, Yunfei
    Dai, Xinhua
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (12) : 3073 - 3083