A study on the system of nonaqueous microchip electrophoresis with on-line peroxyoxalate chemiluminescence detection

被引:14
|
作者
Hu, Hong-Mei [1 ,2 ]
Yin, Xue-Feng [1 ]
Wang, Xiu-Zhong [1 ,3 ]
Shen, Hong [1 ]
机构
[1] Zhejiang Univ, Dept Chem, Inst Microanalyt Syst, Hangzhou 310058, Zhejiang, Peoples R China
[2] Marine Fishery Inst Zhejiang Prov, Zhejiang Prov Key Lab Mariculture & Enhancement, Zhoushan, Peoples R China
[3] Qingdao Agr Univ, Coll Chem & Pharmaceut Sci, Qingdao, Peoples R China
基金
中国国家自然科学基金;
关键词
Nonaqueous microchip electrophoresis; Peroxyoxalate chemiluminescence; Polycyclic aromatic hydrocarbon; Porous polymer plug; Rhodamine; LIQUID-LIQUID-EXTRACTION; CAPILLARY-ELECTROPHORESIS; MICROFLUIDIC CHIP; RHODAMINE; 6G; HYDROGEN-PEROXIDE; ORGANIC-SOLVENTS; INJECTION; ELECTROCHROMATOGRAPHY; FLOW; CHROMATOGRAPHY;
D O I
10.1002/jssc.201200832
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article describes a further development of our previously reported miniaturized analysis system of microchip electrophoresis with on-line chemiluminescence detection. The system, developed first time for nonaqueous microchip electrophoresis with peroxyoxalate chemiluminescence detection, consists of a suction pressure device for sample or reagent introduction, a constant voltage supplied for electrophoretic separation, an either hydrophilic or hydrophobic porous polymer plug for preventing chemiluminescence reagent flowing upstream and a spiral detection channel for enhancement of both detection sensitivity and reproducibility. Especially, by using organic solvent as BGE medium, the developed system avoided the interface problem between aqueous running buffer and low-water-content chemiluminescence solvent in previous reports. The influencing factors on chemiluminescence signal were optimized using rhodamine 6G as model molecule. The system performance was further investigated in the experiment of separation of hydrophilic rhodamine dyes and analysis of hydrophobic polycyclic aromatic hydrocarbon, providing the detection limit (S/N = 3) of 3.5 nmol/L for rhodamine 123, 6.8 nmol/L for rhodamine 6G, and 60 nmol/L for 1-aminopyrene, respectively. The experimental results showed the system offered a number of benefits, including compact structure, high sensitivity, good reproducibility, and a wide range of application prospect.
引用
收藏
页码:713 / 720
页数:8
相关论文
共 50 条
  • [41] Determination of artemisinin in human serum by high-performance liquid chromatography with on-line UV irradiation and peroxyoxalate chemiluminescence detection
    Amponsaa-Karikari, Abena
    Kishikawa, Naoya
    Ohba, Yoshihito
    Nakashima, Kenichiro
    Kuroda, Naotaka
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (11) : 1157 - 1162
  • [42] Nonaqueous electrophoresis microchip separations: Conductivity detection in UV-absorbing solvents
    Wang, J
    Pumera, M
    ANALYTICAL CHEMISTRY, 2003, 75 (02) : 341 - 345
  • [43] DETERMINATION OF ALIPHATIC CARBOXYLIC-ACIDS IN NONAQUEOUS MATRICES BY LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMILUMINESCENCE DETECTION
    GACHANJA, A
    WORSFOLD, P
    ANALYTICA CHIMICA ACTA, 1994, 290 (1-2) : 226 - 232
  • [44] Rapid determination of catecholamines in urine samples by nonaqueous microchip electrophoresis with LIF detection
    Hu, Hongmei
    Li, Zhenhua
    Zhang, Xiaoning
    Xu, Chunxiu
    Guo, Yuanming
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (20) : 3419 - 3425
  • [45] Characterization of dyestuff-containing liposome by capillary zone electrophoresis using on-line chemiluminescence detection
    Tsukagoshi, K
    Akasaka, H
    Nakajima, R
    Hara, T
    CHEMISTRY LETTERS, 1996, (06) : 467 - 468
  • [46] Determination of carbohydrates as their 3-aminophthalhydrazide derivatives by capillary zone electrophoresis with on-line chemiluminescence detection
    Wang, XY
    Wang, Q
    Chen, Y
    Han, HW
    JOURNAL OF CHROMATOGRAPHY A, 2003, 992 (1-2) : 181 - 191
  • [47] A UNIVERSAL PEROXYOXALATE CHEMILUMINESCENCE DETECTION SYSTEM FOR MOBILE PHASES OF DIFFERING PH
    HAYAKAWA, K
    MINOGAWA, E
    YOKOYAMA, T
    MIYAZAKI, M
    IMAI, K
    BIOMEDICAL CHROMATOGRAPHY, 1992, 6 (02) : 84 - 87
  • [48] Capillary-assembled microchip as an on-line deproteinization device for capillary electrophoresis
    Hisamoto, Hideaki
    Takeda, Seigi
    Terabe, Shigeru
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (03) : 733 - 738
  • [49] Capillary-assembled microchip as an on-line deproteinization device for capillary electrophoresis
    Hideaki Hisamoto
    Seigi Takeda
    Shigeru Terabe
    Analytical and Bioanalytical Chemistry, 2006, 386 : 733 - 738
  • [50] On-line coupling of microdialysis sampling with microchip-based capillary electrophoresis
    Huynh, BH
    Fogarty, BA
    Martin, RS
    Lunte, SM
    ANALYTICAL CHEMISTRY, 2004, 76 (21) : 6440 - 6447