A study on the system of nonaqueous microchip electrophoresis with on-line peroxyoxalate chemiluminescence detection

被引:14
|
作者
Hu, Hong-Mei [1 ,2 ]
Yin, Xue-Feng [1 ]
Wang, Xiu-Zhong [1 ,3 ]
Shen, Hong [1 ]
机构
[1] Zhejiang Univ, Dept Chem, Inst Microanalyt Syst, Hangzhou 310058, Zhejiang, Peoples R China
[2] Marine Fishery Inst Zhejiang Prov, Zhejiang Prov Key Lab Mariculture & Enhancement, Zhoushan, Peoples R China
[3] Qingdao Agr Univ, Coll Chem & Pharmaceut Sci, Qingdao, Peoples R China
基金
中国国家自然科学基金;
关键词
Nonaqueous microchip electrophoresis; Peroxyoxalate chemiluminescence; Polycyclic aromatic hydrocarbon; Porous polymer plug; Rhodamine; LIQUID-LIQUID-EXTRACTION; CAPILLARY-ELECTROPHORESIS; MICROFLUIDIC CHIP; RHODAMINE; 6G; HYDROGEN-PEROXIDE; ORGANIC-SOLVENTS; INJECTION; ELECTROCHROMATOGRAPHY; FLOW; CHROMATOGRAPHY;
D O I
10.1002/jssc.201200832
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article describes a further development of our previously reported miniaturized analysis system of microchip electrophoresis with on-line chemiluminescence detection. The system, developed first time for nonaqueous microchip electrophoresis with peroxyoxalate chemiluminescence detection, consists of a suction pressure device for sample or reagent introduction, a constant voltage supplied for electrophoretic separation, an either hydrophilic or hydrophobic porous polymer plug for preventing chemiluminescence reagent flowing upstream and a spiral detection channel for enhancement of both detection sensitivity and reproducibility. Especially, by using organic solvent as BGE medium, the developed system avoided the interface problem between aqueous running buffer and low-water-content chemiluminescence solvent in previous reports. The influencing factors on chemiluminescence signal were optimized using rhodamine 6G as model molecule. The system performance was further investigated in the experiment of separation of hydrophilic rhodamine dyes and analysis of hydrophobic polycyclic aromatic hydrocarbon, providing the detection limit (S/N = 3) of 3.5 nmol/L for rhodamine 123, 6.8 nmol/L for rhodamine 6G, and 60 nmol/L for 1-aminopyrene, respectively. The experimental results showed the system offered a number of benefits, including compact structure, high sensitivity, good reproducibility, and a wide range of application prospect.
引用
收藏
页码:713 / 720
页数:8
相关论文
共 50 条
  • [21] Determination of aromatic compounds by high-performance liquid chromatography with on-line photoreactor and peroxyoxalate chemiluminescence detection
    Ihara, Ayuko
    Kishikawa, Naoya
    Wada, Mitsuhiro
    Ohba, Yoshihito
    Nakashima, Kenichiro
    Kuroda, Naotaka
    LUMINESCENCE, 2007, 22 (06) : 567 - 574
  • [22] An improved apparatus for on-line chemiluminescence detection with capillary electrophoresis and detection of metal-porphyrins
    Zhang, Y
    Gong, ZL
    Zhang, H
    Cheng, JK
    ANALYTICAL COMMUNICATIONS, 1998, 35 (09): : 293 - 296
  • [23] On-line chemiluminescence determination of mitoxantrone by capillary electrophoresis
    Han, Suqin
    Wang, Huili
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (28): : 2901 - 2904
  • [24] Recent advances in chemiluminescence detection coupled with capillary electrophoresis and microchip capillary electrophoresis
    Liu, Yuxuan
    Huang, Xiangyi
    Ren, Jicun
    ELECTROPHORESIS, 2016, 37 (01) : 2 - 18
  • [25] Homogeneous immunoassay of cortisol based on microchip electrophoresis with chemiluminescence detection
    Ye, Fanggui
    Yang, Tinzhen
    Huang, Yong
    Li, Shutin
    Zhao, Shulin
    ANALYTICAL METHODS, 2013, 5 (20) : 5657 - 5661
  • [26] A miniaturized analysis system composed of monolith-based microchip electrochromatography coupled with on-line chemiluminescence detection for amino acids
    Wang, Xiuzhong
    Dong, Shanshan
    Li, Feng
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 225 : 529 - 534
  • [27] Determination of vitamin K homologues by high-performance liquid chromatography with on-line photoreactor and peroxyoxalate chemiluminescence detection
    Ahmed, Sameh
    Kishikawa, Naoya
    Nakashima, Kenichiro
    Kuroda, Naotaka
    ANALYTICA CHIMICA ACTA, 2007, 591 (02) : 148 - 154
  • [28] Determination of organic peroxides by liquid chromatography with on-line post-column ultraviolet irradiation and peroxyoxalate chemiluminescence detection
    Wada, M
    Inoue, K
    Ihara, A
    Kishikawa, N
    Nakashima, K
    Kuroda, N
    JOURNAL OF CHROMATOGRAPHY A, 2003, 987 (1-2) : 189 - 195
  • [29] Capillary electrophoresis/electrochemical detection system with on-line deoxygenation
    Jin, WR
    Dong, Q
    Yu, DQ
    Ye, XY
    Li, W
    ELECTROPHORESIS, 2000, 21 (08) : 1540 - 1544
  • [30] On-line chemiluminescence detection for capillary electrophoresis based on the reaction of barium peroxide with luminescence reagents
    Lin, JM
    Goto, H
    Yamada, M
    JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) : 341 - 348