First clinical experience with the new Surpass Evolve flow diverter: technical and clinical considerations

被引:39
作者
Orru, Emanuele [1 ,2 ]
Rice, Henry [3 ]
De Villiers, Laetitia [3 ]
Klostranec, Jesse M. [1 ]
Wakhloo, Ajay K. [2 ]
Coon, Alexander L. [4 ]
Radovanovic, Ivan [5 ]
Kortman, Hans [1 ]
Bhatia, Kartik Dev [1 ]
Krings, Timo [1 ,5 ]
Pereira, Vitor M. [1 ,5 ]
机构
[1] Toronto Western Hosp, Joint Dept Med Imaging, Div Neuroradiol, Toronto, ON, Canada
[2] Lahey Hosp & Med Ctr, Div Neurointervent Radiol, Burlington, MA 01805 USA
[3] Gold Coast Univ Hosp, Dept Intervent Neuroradiol, Southport, Qld, Australia
[4] Carondelet St Josephs Hosp, Carondelet Neurol Inst, Tucson, AZ USA
[5] Toronto Western Hosp, Univ Hlth Network, Dept Surg, Div Neurosurg, Toronto, ON, Canada
关键词
aneurysm; flow diverter; stent; INTRACRANIAL ANEURYSMS; SINGLE-CENTER; PIPELINE;
D O I
10.1136/neurintsurg-2019-015734
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Objective To describe the results in patients treated with the Surpass Evolve (SE) device, the new generation of Surpass flow diverters. Methods Twenty-five consecutive patients (20 women, average age 58 years), with anterior or posterior circulation aneurysms treated with SEs in two early-user centers, were included. Device properties and related technical properties, imaging and clinical follow-up data, and intraprocedural, early (<30 days) and delayed (>30 days) neurological complications, further divided into minor (silent/non-permanent) and major (permanent) complications, were recorded and analyzed. Results Twenty-nine SEs were successfully implanted in all subjects to treat 26 aneurysms using an 0.027" microcatheter with an average of 1.2 stents per patient. No intraprocedural thromboembolic or hemorrhagic complications were seen. At clinical follow-up, 24/25 (96%) patients had a modified Rankin Score of 0-2. Mortality was 0%. Imaging follow-up, available in 22/25 (88%) patients (median follow-up time 4 months), showed a complete aneurysm occlusion in 13/23 (57%) imaged lesions. Minor, transitory neurological deficits were recorded in 5/25 (20%) patients. One (4%) major complication was seen in one patient (4%) with a left-sided hemispheric stroke on postprocedural day 4 due to an acute stent thrombosis. Conclusions Preliminary experience in patients demonstrates a good performance of the SE. This newly designed implant maintains the engineering characteristics of Surpass flow diverters, including precise placement due to its lower foreshortening and a high mesh density, yet can be deployed through a significantly lower-profile delivery system.
引用
收藏
页码:974 / 980
页数:7
相关论文
共 21 条
[1]   Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical Trial [J].
Becske, Tibor ;
Kallmes, David F. ;
Saatci, Isil ;
McDougall, Cameron G. ;
Szikora, Istvn ;
Lanzino, Giuseppe ;
Moran, Christopher J. ;
Woo, Henry H. ;
Lopes, Demetrius K. ;
Berez, Aaron L. ;
Cher, Daniel J. ;
Siddiqui, Adnan H. ;
Levy, Elad I. ;
Albuquerque, Felipe C. ;
Fiorella, David J. ;
Berentei, Zsolt ;
Marosfoi, Miklos ;
Cekirge, Saruhan H. ;
Nelson, Peter K. .
RADIOLOGY, 2013, 267 (03) :858-868
[2]   Transradial approach for flow diversion treatment of cerebral aneurysms: a multicenter study [J].
Chen, Stephanie H. ;
Snelling, Brian M. ;
Shah, Sumedh Subodh ;
Sur, Samir ;
Brunet, Marie Christine ;
Starke, Robert M. ;
Yavagal, Dileep R. ;
Osbun, Joshua W. ;
Peterson, Eric C. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (08) :796-800
[3]   Flow diversion for treatment of intracranial aneurysms: Mechanism and implications [J].
Chua, Melissa M. J. ;
Silveira, Luke ;
Moore, Justin ;
Pereira, Vitor M. ;
Thomas, Ajith J. ;
Dmytriw, Adam A. .
ANNALS OF NEUROLOGY, 2019, 85 (06) :793-800
[4]   New Generation of Flow Diverter (Surpass) for Unruptured Intracranial Aneurysms A Prospective Single-Center Study in 37 Patients [J].
De Vries, Joost ;
Boogaarts, Jeroen ;
Van Norden, Anouk ;
Wakhloo, Ajay K. .
STROKE, 2013, 44 (06) :1567-1577
[5]  
FDA, SURP STREAML FLOW DI
[6]   Blood blister-like aneurysms: Single center experience and systematic literature review [J].
Gonzalez, Ana Marcos ;
Narata, Ana Paula ;
Yilmaz, Hasan ;
Bijlenga, Philippe ;
Radovanovic, Ivan ;
Schaller, Karl ;
Lovblad, Karl-Olof ;
Pereira, Vitor Mendes .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (01) :197-205
[7]   Prospective study on embolization of intracranial aneurysms with the pipeline device: the PREMIER study 1 year results [J].
Hanel, Ricardo A. ;
Kallmes, David F. ;
Lopes, Demetrius Klee ;
Nelson, Peter Kim ;
Siddiqui, Adnan ;
Jabbour, Pascal ;
Pereira, Vitor M. ;
Istvan, Istvan Szikora ;
Zaidat, Osama O. ;
Bettegowda, Chetan ;
Colby, Geoffrey P. ;
Mokin, Maxim ;
Schirmer, Clemens ;
Hellinger, Frank R. ;
Given, Curtis, II ;
Krings, Timo ;
Taussky, Philipp ;
Toth, Gabor ;
Fraser, Justin F. ;
Chen, Michael ;
Priest, Ryan ;
Kan, Peter ;
Fiorella, David ;
Frei, Don ;
Aagaard-Kienitz, Beverly ;
Diaz, Orlando ;
Malek, Adel M. ;
Cawley, C. Michael ;
Puri, Ajit S. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (01) :62-66
[8]   Flow-diverter Stents for Internal Carotid Artery Reconstruction Following Spontaneous Dissection: A Technical Report [J].
Hilditch, Christopher Alan ;
Brinjikji, Waleed ;
Schaafsma, Joanna ;
Tsang, Chun On Anderson ;
Nicholson, Patrick ;
Agid, Ronit ;
Krings, Timo ;
Pereira, Vitor M. .
CLINICAL NEURORADIOLOGY, 2019, 29 (04) :707-715
[9]   Aneurysm Study of Pipeline in an Observational Registry (ASPIRe) [J].
Kallmes, David F. ;
Brinjikji, Waleed ;
Boccardi, Edoardo ;
Ciceri, Elisa ;
Diaz, Orlando ;
Tawk, Rabih ;
Woo, Henry ;
Jabbour, Pascal ;
Albuquerque, Felipe ;
Chapot, Rene ;
Bonafe, Alain ;
Dashti, Shervin R. ;
Almandoz, Josser E. Delgado ;
Given, Curtis, II ;
Kelly, Michael E. ;
Cross, DeWitte T., III ;
Duckwiler, Gary ;
Razack, Nasser ;
Powers, Ciaran J. ;
Fischer, Sebastian ;
Lopes, Demetrius ;
Harrigan, Mark R. ;
Huddle, Daniel ;
Turner, Raymond ;
Zaidat, Osama O. ;
Defreyne, Luc ;
Pereira, Vitor Mendes ;
Cekirge, Saruhan ;
Fiorella, David ;
Hanel, Ricardo A. ;
Lylyk, Pedro ;
McDougall, Cameron ;
Siddiqui, Adnan ;
Szikora, Istvan ;
Levy, Elad .
INTERVENTIONAL NEUROLOGY, 2016, 5 (1-2) :89-99
[10]   Communicating malapposition of flow diverters assessed with optical coherence tomography correlates with delayed aneurysm occlusion [J].
King, Robert M. ;
Brooks, Olivia W. ;
Langan, Erin T. ;
Caroff, Jildaz ;
Clarencon, Frederic ;
Tamura, Takamitsu ;
Wainwright, John Michael ;
Gounis, Matthew J. ;
Marosfoi, Miklos ;
Puri, Ajit S. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2018, 10 (07) :697-+