A Brief History of Free-Response Receiver Operating Characteristic Paradigm Data Analysis

被引:53
作者
Chakraborty, Dev P. [1 ]
机构
[1] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15213 USA
基金
美国国家卫生研究院;
关键词
ROC; free-response; FROC; localization tasks; observer performance; JAFROC; software; DORFMAN-BERBAUM-METZ; OBSERVER-PERFORMANCE; SIGNAL DETECTABILITY; FROC CURVES; LOCALIZATION; MODEL; ROC; VALIDATION; SEARCH; ABNORMALITIES;
D O I
10.1016/j.acra.2013.03.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In the receiver operating characteristic paradigm the observer assigns a single rating to each image and the location of the,perceived abnormality, if any, is ignored. In the free-response receiver operating characteristic paradigm the observer is free to mark and rate as many suspicious regions as are considered clinically reportable. Credit for a correct localization is given only if a mark is sufficiently close to an actual lesion; otherwise, the observer's mark is scored as a location-level false positive. Until fairly recently there existed no accepted method for analyzing the resulting relatively unstructured data containing random numbers of mark-rating pairs per image. This report reviews the history of work in this field, which has now spanned more than five decades. It introduces terminology used to describe the paradigm, proposed measures of performance (figures of merit), ways of visualizing the data (operating characteristics), and software for analyzing free-response receiver operating characteristic studies.
引用
收藏
页码:915 / 919
页数:5
相关论文
共 43 条
  • [1] Area under the Free-Response ROC Curve (FROC) and a Related Summary Index
    Bandos, Andriy I.
    Rockette, Howard E.
    Song, Tao
    Gur, David
    [J]. BIOMETRICS, 2009, 65 (01) : 247 - 256
  • [2] Components-of-variance models and multiple-bootstrap experiments: An alternative method for random-effects, receiver operating characteristic analysis
    Beiden, SV
    Wagner, RF
    Campbell, G
    [J]. ACADEMIC RADIOLOGY, 2000, 7 (05) : 341 - 349
  • [3] SATISFACTION OF SEARCH IN DIAGNOSTIC-RADIOLOGY
    BERBAUM, KS
    FRANKEN, EA
    DORFMAN, DD
    ROOHOLAMINI, SA
    KATHOL, MH
    BARLOON, TJ
    BEHLKE, FM
    SATO, Y
    LU, CH
    ELKHOURY, GY
    FLICKINGER, FW
    MONTGOMERY, WJ
    [J]. INVESTIGATIVE RADIOLOGY, 1990, 25 (02) : 133 - 140
  • [4] BUNCH PC, 1978, J APPL PHOTOGR ENG, V4, P166
  • [5] ROC curves predicted by a model of visual search
    Chakraborty, D. P.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (14) : 3463 - 3482
  • [6] A search model and figure of merit for observer data acquired according to the free-response paradigm
    Chakraborty, D. P.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (14) : 3449 - 3462
  • [7] INVERSE DEPENDENCE OF SEARCH AND CLASSIFICATION PERFORMANCES IN LESION LOCALIZATION TASKS
    Chakraborty, D. P.
    Yoon, Hong-Jun
    Mello-Thoms, Claudia
    [J]. MEDICAL IMAGING 2012: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2012, 8318
  • [8] Spatial localization accuracy of radiologists in free-response studies: Inferring perceptual FROC curves from mark-rating data
    Chakraborty, Dev
    Yoon, Hong-Jun
    Mello-Thoms, Claudia
    [J]. ACADEMIC RADIOLOGY, 2007, 14 (01) : 4 - 18
  • [9] New Developments in Observer Performance Methodology in Medical Imaging
    Chakraborty, Dev P.
    [J]. SEMINARS IN NUCLEAR MEDICINE, 2011, 41 (06) : 401 - 418
  • [10] Recent developments in imaging system assessment methodology, FROC analysis and the search model
    Chakraborty, Dev P.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S297 - S301