A Study of the Effects of Geometry on the Efficiency of Single Slot Microwave Ablation Antennas used in Hepatic Tumor Hyperthermia

被引:2
作者
Neagu, V. [1 ]
机构
[1] Tech Univ Cluj Napoca, Fac Elect Engn, Cluj Napoca, Romania
来源
INTERNATIONAL CONFERENCE ON ADVANCEMENTS OF MEDICINE AND HEALTH CARE THROUGH TECHNOLOGY, MEDITECH 2016 | 2017年 / 59卷
关键词
microwave; ablation; tumor; simulation; optimization; EX-VIVO BOVINE; DEVICES; LIVER;
D O I
10.1007/978-3-319-52875-5_30
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Microwave ablation (MWA) has gained appreciation as an alternative to radio frequency ablation in the treatment of tumors. In this paper, COMSOL Multiphysics software is used to perform an analysis of single slot, end capped MWA antenna with a variable geometry fed at a frequency range between 900MHz and 2500MHz, with the purpose of finding configurations that reduce reflections, increase the power transfer to the hepatic tissue and produce faster heating, giving a more efficient antenna design.
引用
收藏
页码:131 / 136
页数:6
相关论文
共 10 条
[1]   Antenna design for microwave hepatic ablation using an axisymmetric electromagnetic model [J].
Bertram, John M. ;
Yang, Deshan ;
Converse, Mark C. ;
Webster, John G. ;
Mahvi, David M. .
BIOMEDICAL ENGINEERING ONLINE, 2006, 5 (1)
[2]   Microwave ablation: Results with a 2.45-GHz applicator in ex vivo bovine and in vivo porcine liver [J].
Hines-Peralta, AU ;
Pirani, N ;
Clegg, P ;
Cronin, N ;
Ryan, TP ;
Liu, ZJ ;
Goldberg, SN .
RADIOLOGY, 2006, 239 (01) :94-102
[3]   Comparison of Four Microwave Ablation Devices: An Experimental Study in ex Vivo Bovine Liver [J].
Hoffmann, Ruediger ;
Rempp, Hansjoerg ;
Erhard, Ludwig ;
Blumenstock, Gunnar ;
Pereira, Philippe L. ;
Claussen, Claus D. ;
Clasen, Stephan .
RADIOLOGY, 2013, 268 (01) :89-97
[4]  
Lloyd D. M., 2008, INT MICROWAVE TUMOUR, V13, P579
[5]  
Lubner M. G., 2010, J VASC INTERV RADI S, V21, pS192
[6]   Microwave hepatic ablation: Initial experience of safety and efficacy [J].
Martin, Robert C. G. ;
Scoggins, Charles R. ;
McMasters, Kelly M. .
JOURNAL OF SURGICAL ONCOLOGY, 2007, 96 (06) :481-486
[7]   Radiofrequency ablation of the liver: Current status [J].
McGahan, JP ;
Dodd, GD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (01) :3-16
[9]   MICROWAVE MEDICAL DEVICES [J].
Sterzer, Fred .
IEEE MICROWAVE MAGAZINE, 2002, 3 (01) :65-70
[10]   Radiofrequency versus microwave ablation in a hepatic porcine model [J].
Wright, AS ;
Sampson, LA ;
Warner, TF ;
Mahvi, DM ;
Lee, FT .
RADIOLOGY, 2005, 236 (01) :132-139