Preventing peripheral intravenous catheter failure by reducing mechanical irritation

被引:33
作者
Takahashi, Toshiaki [1 ]
Murayama, Ryoko [2 ,3 ]
Abe-Doi, Mari [2 ]
Miyahara-Kaneko, Maki [4 ]
Kanno, Chiho [4 ]
Nakamura, Miwa [5 ]
Mizuno, Mariko [5 ]
Komiyama, Chieko [5 ]
Sanada, Hiromi [3 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Life Support Technol Molten, Tokyo, Japan
[2] Univ Tokyo, Grad Sch Med, Dept Adv Nursing Technol, Tokyo, Japan
[3] Univ Tokyo, Grad Sch Med, Global Nursing Res Ctr, Tokyo, Japan
[4] Univ Tokyo, Grad Sch Med, Dept Gerontol Nursing Wound Care Management, Tokyo, Japan
[5] Univ Tokyo Hosp, Dept Nursing, Tokyo, Japan
关键词
MICHIGAN APPROPRIATENESS GUIDE; PROPENSITY SCORE; BUNDLE APPROACH; RISK-FACTORS; INFUSION; THROMBOPHLEBITIS; EPIDEMIOLOGY; PHLEBITIS; CARE; ULTRASONOGRAPHY;
D O I
10.1038/s41598-019-56873-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Peripheral intravenous catheter failure is a significant concern in the clinical setting. We investigated the effectiveness of care protocols, including an ultrasonographic "pre-scan" for selecting a largediameter vein before catheterization, a "post-scan" for confirming the catheter tip position after catheterization with ultrasonography, and the use of a flexible polyurethane catheter to reduce the mechanical irritation that contributes to the incidence of catheter failure. This intervention study was a non-randomized controlled trial to investigate the effectiveness of the abovementioned care protocols, the effects of which were compared to the outcomes in the control group, which received conventional care. For both groups, participants were selected from patients in two wards at the University of Tokyo in Japan between July and November 2017. Inverse probability score-based weighted methods (IPW) using propensity score were used to estimate the effectiveness of care protocols. The primary outcome was catheter failure, which was defined as accidental and unplanned catheter removal. We used KaplanMeier survival curves to compare rates of time until catheter failure. We analysed 189 and 233 catheters in the intervention and control groups, respectively. In the control group, 68 catheters (29.2%) were determined to have failed, whereas, in the intervention group, only 21 catheters (11.1%) failed. There was a significant difference between each group regarding the ratio of catheter failure adjusted according to IPW (p = 0.003). The relative risk reduction of the intervention for catheter failure was 0.60 (95% CI: 0.47-0.71). Care protocols, including assessment of vein diameter, vein depth, and catheter tip location using ultrasound examination for reducing mechanical irritation is a promising method to reduce catheter failure incidence.
引用
收藏
页数:13
相关论文
共 69 条
[1]  
[Anonymous], 2015, J VASC ACCESS
[2]   Ultrasound Assessment of Deep Tissue Injury in Pressure Ulcers: Possible Prediction of Pressure Ulcer Progression [J].
Aoi, Noriyuki ;
Yoshimura, Kotaro ;
Kadono, Takafumi ;
Nakagami, Gojiro ;
Iizuka, Shinji ;
Higashino, Takuya ;
Araki, Jun ;
Koshima, Isao ;
Sanada, Hiromi .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2009, 124 (02) :540-550
[3]   ASPEN Clinical Guidelines Parenteral Nutrition Ordering, Order Review, Compounding, Labeling, and Dispensing [J].
Boullata, Joseph I. ;
Gilbert, Karen ;
Sacks, Gordon ;
Labossiere, Reginald J. ;
Crill, Cathy ;
Goday, Praveen ;
Kumpf, Vanessa J. ;
Mattox, Todd W. ;
Plogsted, Steve ;
Holcombe, Beverly .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2014, 38 (03) :334-377
[4]  
Brandt C T, 2000, Ugeskr Laeger, V162, P4531
[5]   Ventilator bundle approach to prevention of ventilator-associated pneumonia [J].
Burger, Charles D. ;
Resar, Roger K. .
MAYO CLINIC PROCEEDINGS, 2006, 81 (06) :849-850
[6]  
Chopra V, 2017, J INFUS MURS, V40, P15, DOI 10.1097/NAN.0000000000000203
[7]   Vascular nursing experience, practice knowledge, and beliefs: Results from the michigan PICC1 survey [J].
Chopra, Vineet ;
Kuhn, Latoya ;
Ratz, David ;
Flanders, Scott A. ;
Krein, Sarah L. .
JOURNAL OF HOSPITAL MEDICINE, 2016, 11 (04) :269-275
[8]   The Michigan Appropriateness Guide for Intravenous Catheters (MAGIC): Results From a Multispecialty Panel Using the RAND/UCLA Appropriateness Method [J].
Chopra, Vineet ;
Flanders, Scott A. ;
Saint, Sanjay ;
Woller, Scott C. ;
O'Grady, Naomi P. ;
Safdar, Nasia ;
Trerotola, Scott O. ;
Saran, Rajiv ;
Moureau, Nancy ;
Wiseman, Stephen ;
Pittiruti, Mauro ;
Akl, Elie A. ;
Lee, Agnes Y. ;
Courey, Anthony ;
Swaminathan, Lakshmi ;
LeDonne, Jack ;
Becker, Carol ;
Krein, Sarah L. ;
Bernstein, Steven J. .
ANNALS OF INTERNAL MEDICINE, 2015, 163 (06) :S1-+
[9]   Risk of venous thromboembolism associated with peripherally inserted central catheters: a systematic review and meta-analysis [J].
Chopra, Vineet ;
Anand, Sarah ;
Hickner, Andy ;
Buist, Michael ;
Rogers, Mary A. M. ;
Saint, Sanjay ;
Flanders, Scott A. .
LANCET, 2013, 382 (9889) :311-325
[10]  
Christopher L., 2011, NEW ENGL J MED, V364, P9