Worldwide Experience with the Robotic Navigation System in Catheter Ablation of Atrial Fibrillation: Methodology, Efficacy and Safety

被引:48
作者
Bai, Rong [1 ]
Di Biase, Luigi [1 ]
Valderrabano, Miguel [2 ]
Lorgat, Faizel [3 ]
Mlcochova, Hanka [4 ]
Tilz, Roland [5 ]
Meyerfeldt, Udo [6 ]
Hranitzky, Patrick M. [7 ]
Wazni, Oussama [8 ]
Kanagaratnam, Prapa [9 ]
Doshi, Rahul N. [10 ]
Gibson, Douglas [11 ]
Pisapia, Andre [12 ]
Mohanty, Prasant [1 ]
Saliba, Walid [8 ]
Ouyang, Feifan [5 ]
Kautzner, Josef [4 ]
Gallinghouse, G. Joseph [1 ]
Natale, Andrea [1 ]
机构
[1] St Davids Med Ctr, Texas Cardiac Arrhythmia Inst, Austin, TX 78705 USA
[2] Methodist DeBakey Heart & Vasc Ctr, Houston, TX USA
[3] Christiaan Barnard Mem Hosp, Cape Town, South Africa
[4] Inst Clin & Expt Med, Dept Cardiol, Prague, Czech Republic
[5] Asklepios Klin St Georg, Med Klin, Dept Cardiol, Hamburg, Germany
[6] Schwarzwald Baar Hosp, Dept Elect, Villingen Schwenningen, Germany
[7] Duke Univ, Med Ctr, Div Cardiol, Durham, NC 27710 USA
[8] Cleveland Clin, Dept Cardiovasc Med, Cleveland, OH 44106 USA
[9] Imperial Coll Healthcare NHS Trust, St Marys Hosp, London, England
[10] St Jude Med Ctr, Fullerton, CA USA
[11] Intervent Elect Scripps Clin, San Diego, CA USA
[12] St Joseph Hosp, Marseille, France
关键词
atrial fibrillation; catheter ablation; remote; robotic navigation; safety; IMPACT;
D O I
10.1111/j.1540-8167.2012.02316.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Worldwide Survey on Robotic AF Ablation. Introduction: The Hansen Robotic system has been utilized in ablation procedures for atrial fibrillation (AF). However, because of the lack of tactile feedback and the rigidity of the robotic sheath, this approach could result in higher risk of complications. This worldwide survey reports a multicenter experience on the methodology, efficacy, and safety of the Hansen system in AF ablations. Methods and Results: A questionnaire addressing questions on patient's demographics, procedural parameters, ablation success rate and safety information was sent to all centers where more than 50 robotic AF ablation cases have been performed. From June 2007 to December 2009, 1,728 procedures were performed at 12 centers utilizing the Hansen robotic navigation technology. The overall complication rate was 4.7% and the success rate was 67.1% after 18 +/- 4 months of follow-up. In 5 low volume centers there appeared to be a learning curve of about 50 cases (complication rate 11.2% for the first 50 cases vs 3.7% for the 51100 cases; P = 0.044) and a trend showing a decrease of complication rate with increasing case volume. However, in the remaining 7 centers no learning curve was present and the complication rate was stable over time (3.7% for the first 50 cases vs 3.6% for the 51st case thereafter; P = 0.942). Conclusion: The Hansen robotic system can be used for AF ablation safely. In low volume centers, there appeared to be a learning curve of the first 50 cases after which the complication rate decreased. With a higher case volume, the success rate increased. (J Cardiovasc Electrophysiol, Vol. 23, pp. 820-826, August 2012)
引用
收藏
页码:820 / 826
页数:7
相关论文
共 16 条
[1]   Impact of type of atrial fibrillation and repeat catheter ablation on long-term freedom from atrial fibrillation: Results from a multicenter study [J].
Bhargava, Mandeep ;
Di Biase, Luigi ;
Mohanty, Prasant ;
Prasad, Subramanyam ;
Martin, David O. ;
Williams-Andrews, Michelle ;
Wazni, Oussama M. ;
Burkhardt, J. David ;
Cummings, Jennifer E. ;
Khaykin, Yaariv ;
Verma, Atul ;
Hao, Steven ;
Beheiry, Salwa ;
Hongo, Richard ;
Rossillo, Antonio ;
Raviele, Antonio ;
Bonso, Aldo ;
Themistoclakis, Sakis ;
Stewart, Kelly ;
Saliba, Walid I. ;
Schweikert, Robert A. ;
Natale, Andrea .
HEART RHYTHM, 2009, 6 (10) :1403-1412
[2]   Can we improve upon human performance in the electrophysiology laboratory? [J].
Callans, David J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (25) :2412-2413
[3]  
Camm AJ, 2010, EUROPACE, V12, P1360, DOI [10.1093/europace/euq350, 10.1093/eurheartj/ehq278]
[4]   Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial Fibrillation [J].
Cappato, Riccardo ;
Calkins, Hugh ;
Chen, Shih-Ann ;
Davies, Wyn ;
Iesaka, Yoshito ;
Kalman, Jonathan ;
Kim, You-Ho ;
Klein, George ;
Natale, Andrea ;
Packer, Douglas ;
Skanes, Allan ;
Ambrogi, Federico ;
Biganzoli, Elia .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2010, 3 (01) :32-38
[5]   Ablation of Atrial Fibrillation Utilizing Robotic Catheter Navigation in Comparison to Manual Navigation and Ablation: Single-Center Experience [J].
Di Biase, Luigi ;
Wang, Yan ;
Horton, Rodney ;
Gallinghouse, G. Joseph ;
Mohanty, Prasant ;
Sanchez, Javier ;
Patel, Dimpi ;
Dare, Matthew ;
Canby, Robert ;
Price, Larry D. ;
Zagrodzky, Jason D. ;
Bailey, Shane ;
Burkhardt, J. David ;
Natale, Andrea .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (12) :1328-1335
[6]   Relationship Between Catheter Forces, Lesion Characteristics, "Popping," and Char Formation: Experience with Robotic Navigation System [J].
Di Biase, Luigi ;
Natale, Andrea ;
Barrett, Conor ;
Tan, Carmela ;
Elayi, Claude S. ;
Ching, Chi Keong ;
Wang, Paul ;
Al-Ahmad, Amin ;
Arruda, Mauricio ;
Burkhardt, J. David ;
Wisnoskey, Brian J. ;
Chowdhury, Punam ;
De Marco, Shari ;
Armaganijan, Luciana ;
Litwak, Kenneth N. ;
Schweikert, Robert A. ;
Cummings, Jennifer E. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (04) :436-440
[7]   Remote magnetic navigation - Human experience in pulmonary vein ablation [J].
Di Blase, Luigi ;
Fahmy, Tamer S. ;
Patel, Dimpi ;
Bai, Rong ;
Civello, Kenneth ;
Wazni, Oussama M. ;
Kanj, Mohamed ;
Elayi, Claude S. ;
Ching, Chi Keong ;
Khan, Mohamed ;
Popova, Lucie ;
Schweikert, Robert A. ;
Cummings, Jennifer E. ;
Burkhardt, J. David ;
Martin, David O. ;
Bhargava, Mandeep ;
Dresing, Thomas ;
Saliba, Walid ;
Arruda, Mauricio ;
Natale, Andrea .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (09) :868-874
[8]   Robotic Navigation in Catheter Ablation for Paroxysmal Atrial Fibrillation: Midterm Efficacy and Predictors of Postablation Arrhythmia Recurrences [J].
Hlivak, Peter ;
Mlcochova, Hanka ;
Peichl, Petr ;
Cihak, Robert ;
Wichterle, Dan ;
Kautzner, Josef .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (05) :534-540
[9]   Experience of robotic catheter ablation in humans using a novel remotely steerable catheter sheath [J].
Kanagaratnam, Prapa ;
Koa-Wing, Michael ;
Wallace, Daniel T. ;
Goldenberg, Alex S. ;
Peters, Nicholas S. ;
Davies, D. Wyn .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2008, 21 (01) :19-26
[10]   Early Experience with Robotic Navigation for Catheter Ablation of Paroxysmal Atrial Fibrillation [J].
Kautzner, Josef ;
Peichl, Petr ;
Cihak, Robert ;
Wichterle, Dan ;
Mlcochova, Hanka .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 :S163-S166