On-line monitoring technology for the insulation condition of capacitive-type substation equipment

被引:0
|
作者
Hao, Xi-Wei [1 ]
Zhang, Guan-Jun [1 ]
Zhang, Wei [1 ]
Dong, Ming [1 ]
Liu, Guang-Yan [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, State Key Lab Elect Insulat & Power Equipment, 28 Xianning W Rd, Xian 710049, Peoples R China
[2] Shandong Electr Power Res Inst, Jinan 250002, Peoples R China
来源
PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS | 2007年
基金
国家高技术研究发展计划(863计划);
关键词
capacitive-type equipment; on-line monitoring; DSP plus FPGA; high accuracy FFT algorithm; measurement precision;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An on-line monitoring system for the insulation condition of capacitive-type equipment is described. The system adopts a distributed and layered multi-CPU structure, which is composed of the on-site measuring and processing unit, and data management and diagnosis system in the control room of substation. The on-site measuring and processing unit is based on DSP+FPGA hardware platform. Thus, the hardware design is simplified, the system is easy to be modified and updated, and the reliability is also raised. The windows and interpolation algorithm is applied to effectively reduce the influence of asynchronous sampling caused by frequency fluctuation of power system and to increase the precision. Moreover, many and jamming and protection methods are used in hardware and software design for the on-site intense electromagnetic field. Based on the simulation test conducted in the laboratory, the experimental results prove that measurement accuracy of the on-line monitoring system, which can meet the demand of on-site measurement.
引用
收藏
页码:1220 / +
页数:2
相关论文
共 50 条
  • [1] A new on-line insulation diagnostic method for capacitive-type equipment
    Huang, XH
    Bai, F
    Gao, WS
    Yan, Z
    POWERCON '98: 1998 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY - PROCEEDINGS, VOLS 1 AND 2, 1998, : 100 - 104
  • [2] Study on the on-line dielectric loss tangent monitoring technique of capacitive-type equipment
    Hao, JJ
    Ma, YJ
    Huang, JH
    Zhang, JG
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 2, 2005, : 221 - 223
  • [3] Key techniques for on-line monitoring system of insulation of capacitive equipment
    Wang, Jian
    Journal of Applied Sciences, 2013, 13 (16) : 3145 - 3152
  • [4] Design and Implementation of On-Line Monitoring System of Substation equipment
    Li, Xiao-ying
    Zhang, Dan
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON AUTOMATION, MECHANICAL CONTROL AND COMPUTATIONAL ENGINEERING, 2015, 124 : 560 - 565
  • [5] Developing Capacitive Equipment On-Line Monitoring Intelligence Software
    Zhang, Weicong
    Yang, Lichun
    FOURTH INTERNATIONAL CONFERENCE ON MACHINE VISION (ICMV 2011): MACHINE VISION, IMAGE PROCESSING, AND PATTERN ANALYSIS, 2012, 8349
  • [6] Research on Functional Testing of Substation Equipment On-line Monitoring System
    Di, Jian
    Li, Shuo
    Wang, Dewen
    RENEWABLE ENERGY AND ENVIRONMENTAL TECHNOLOGY, PTS 1-6, 2014, 448-453 : 2384 - 2388
  • [7] Multidimensional information of aggregation technology for on-line monitoring of substation
    Zhai, Shaolei
    Cao, Min
    Shen, Xin
    Wang, Fei
    Wang, En
    Gaodianya Jishu/High Voltage Engineering, 2015, 41 (12): : 3973 - 3979
  • [8] Application of Synthetic Relative Measuring Method in On-Line Monitoring for Capacitive Equipment
    Guo Qing
    Qin Lijun
    Hao Cuijuan
    Wang Ying
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON SMART GRID AND CLEAN ENERGY TECHNOLOGIES (ICSGCE 2011), 2011, 12
  • [10] Fuzzy Comprehensive Evaluation Method for On-line Monitoring Data Quality of Substation Equipment
    Fu Dehui
    Wang Feng
    Yuan Shuai
    Wang Guangzhen
    Shao Mingxin
    2019 6TH INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE AND CONTROL ENGINEERING (ICISCE 2019), 2019, : 753 - 757