Evaluation of gastric emptying measured with the 13C-octanoic acid breath test in patients with functional dyspepsia comparison with ultrasonography

被引:31
作者
Aoki, S
Haruma, K
Kusunoki, H
Hata, J
Hara, M
Yoshida, S
Tanaka, S
Chayama, K
机构
[1] Kawasaki Med Sch, Dept Intestinal Med, Div Gastroenterol, Kurashiki, Okayama 7010192, Japan
[2] Hiroshima Univ, Sch Med, Dept Intestinal Med 1, Gastrointestinal Unit, Hiroshima 730, Japan
关键词
breath test; functional dyspepsia; gastric emptying; octanoic acid; ultrasonography;
D O I
10.1080/00365520212508
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: As a non-invasive modality by which to evaluate the gastric emptying of a solid meal, the C-13-octanoic acid breath test has recently become more widely used. Previously, we reported that ultrasonography was another non-invasive and reliable method for assessing gastric motility. The aim of this study was to compare the reliability of these two methods. Methods: Seventeen patients with functional dyspepsia and 10 healthy volunteers were studied. The solid test meal consisted of a scrambled egg labeled with C-13-octanoic acid (100 mg) and served with a bowl of rice and boiled chicken (total 424 kcal). After ingestion of the test meal, all subjects were examined in the sitting position. Ultrasonograph y images were obtained every 15 min for 3 h. Breath sampling followed the same time schedule as for the ultrasonography, with an additional 3 h of sampling at 30-min intervals. We investigated the half emptying time (T1/2) and the lag phase with both methods. Results: The T1/2 by the ultrasonography method and the breath test were positively correlated (r(2) = 0.638); however, there was no significant agreement between the study groups. Both the T1/2 and the lag phase were prolonged in the functional dyspepsia patients compared with the healthy volunteers, regardless of the method of measurement. The lag phase was significantly correlated (r(2) = 0.864) with the T1/2 by the breath test. Conclusions: Although the C-13-octanoic acid breath test cannot assess the gastric emptying of solids as reliably as ultrasonography, both tests are useful for evaluating functional dyspepsia patients with delayed gastric emptying.
引用
收藏
页码:662 / 666
页数:5
相关论文
共 35 条
[1]  
BATEMAN DN, 1982, GUT, V23, P524, DOI 10.1136/gut.23.6.524
[2]   Simultaneous measurement of gastric emptying of a solid meal by ultrasound and by scintigraphy [J].
Benini, L ;
Sembenini, C ;
Heading, RC ;
Giorgetti, PG ;
Montemezzi, S ;
Zamboni, M ;
Di Benedetto, P ;
Brighenti, F ;
Vantini, I .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 1999, 94 (10) :2861-2865
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   MEASUREMENT OF GASTRIC-EMPTYING TIME BY REAL-TIME ULTRASONOGRAPHY [J].
BOLONDI, L ;
BORTOLOTTI, M ;
SANTI, V ;
CALLETTI, T ;
GAIANI, S ;
LABO, G .
GASTROENTEROLOGY, 1985, 89 (04) :752-759
[5]   THE [C-13]ACETATE BREATH TEST ACCURATELY REFLECTS GASTRIC-EMPTYING OF LIQUIDS IN BOTH LIQUID AND SEMISOLID TEST MEALS [J].
BRADEN, B ;
ADAMS, S ;
DUAN, LP ;
ORTH, KH ;
MAUL, FD ;
LEMBCKE, B ;
HOR, G ;
CASPARY, WF .
GASTROENTEROLOGY, 1995, 108 (04) :1048-1055
[6]  
Cappello G, 2000, AM J GASTROENTEROL, V95, P3097
[7]  
Chang CS, 1996, AM J GASTROENTEROL, V91, P474
[8]   Reproducibility and simplification of 13C-octanoic acid breath test for gastric emptying of solids [J].
Choi, MG ;
Camilleri, M ;
Burton, DD ;
Zinsmeister, AR ;
Forstrom, LA ;
Nair, KS .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 1998, 93 (01) :92-98
[9]  
COLINJONES DG, 1988, LANCET, V1, P576
[10]   GASTRIC-EMPTYING IN NORMAL SUBJECTS - A REPRODUCIBLE TECHNIQUE USING A SINGLE SCINTILLATION CAMERA AND COMPUTER-SYSTEM [J].
COLLINS, PJ ;
HOROWITZ, M ;
COOK, DJ ;
HARDING, PE ;
SHEARMAN, DJC .
GUT, 1983, 24 (12) :1117-1125