Materials for Hip Prostheses: A Review of Wear and Loading Considerations

被引:192
作者
Merola, Massimiliano [1 ]
Affatato, Saverio [1 ]
机构
[1] IRCCS Ist Ortoped Rizzoli, Lab Tecnol Med, Via Barbiano 1, I-40136 Bologna, Italy
关键词
biomaterials; ceramic; friction; hip; implants; polyethylene; prosthesis; simulator; wear; METAL-ON-METAL; CROSS-LINKED POLYETHYLENE; MOLECULAR-WEIGHT POLYETHYLENE; MONOCLINIC PHASE-TRANSFORMATION; TOUGHENED ALUMINA CERAMICS; REVISION TOTAL HIP; IN-VITRO; IRRADIATED UHMWPE; ALPHA-TOCOPHEROL; ZRO2; FRACTION;
D O I
10.3390/ma12030495
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Replacement surgery of hip joint consists of the substitution of the joint with an implant able to recreate the articulation functionality. This article aims to review the current state of the art of the biomaterials used for hip implants. Hip implants can be realized with different combination of materials, such as metals, ceramics and polymers. In this review, we analyze, from international literature, the specific characteristics required for biomaterials used in hip joint arthroplasty, i.e., being biocompatible, resisting heavy stress, opposing low frictional forces to sliding and having a low wear rate. A commentary on the evolution and actual existing hip prostheses is proposed. We analyzed the scientific literature, collecting information on the material behavior and the human-body response to it. Particular attention has been given to the tribological behavior of the biomaterials, as friction and wear have been key aspects to improve as hip implants evolve. After more than 50 years of evolution, in term of designs and materials, the actual wear rate of the most common implants is low, allowing us to sensibly reduce the risk related to the widespread debris distribution in the human body.
引用
收藏
页数:24
相关论文
共 155 条
  • [1] Advanced nanocomposite materials for orthopaedic applications.: I.: A long-term in vitro wear study of zirconia-toughened alumina
    Affatato, S
    Torrecillas, R
    Taddei, P
    Rocchi, M
    Fagnano, C
    Ciapetti, G
    Toni, A
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2006, 78B (01) : 76 - 82
  • [2] Mixed oxides prosthetic ceramic ball heads.: Part 1:: effect of the ZrO2 fraction on the wear of ceramic on polyethylene joints
    Affatato, S
    Testoni, M
    Cacciari, GL
    Toni, A
    [J]. BIOMATERIALS, 1999, 20 (10) : 971 - 975
  • [3] Retrieval analysis of three generations of Biolox® femoral heads: Spectroscopic and SEM characterisation
    Affatato, S.
    Modena, E.
    Toni, A.
    Taddei, P.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 13 : 118 - 128
  • [4] Is Ceramic-On-Ceramic Squeaking Phenomenon Reproducible In Vitro? A Long-Term Simulator Study Under Severe Conditions
    Affatato, S.
    Traina, F.
    Mazzega-Fabbro, C.
    Sergo, V.
    Viceconti, M.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 91B (01) : 264 - 271
  • [5] Mixed oxides prosthetic ceramic ball heads.: Part 3:: effect of the ZrO2 fraction on the wear of ceramic on ceramic hip joint prostheses.: A long-term in vitro wear study
    Affatato, S
    Goldoni, M
    Testoni, M
    Toni, A
    [J]. BIOMATERIALS, 2001, 22 (07) : 717 - 723
  • [6] Affatato S., 2014, Perspectives in Total Hip Arthroplasty, Advances in Biomaterials and their Tribological interactions
  • [7] Wear performance of neat and vitamin E blended highly cross-linked PE under severe conditions: The combined effect of accelerated ageing and third body particles during wear test
    Affatato, Saverio
    De Mattia, Jonathan Salvatore
    Bracco, Pierangiola
    Pavoni, Eleonora
    Taddei, Paola
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 64 : 240 - 252
  • [8] Advanced biomaterials in hip joint arthroplasty. A review on polymer and ceramics composites as alternative bearings
    Affatato, Saverio
    Ruggiero, Alessandro
    Merola, Massimiliano
    [J]. COMPOSITES PART B-ENGINEERING, 2015, 83 : 276 - 283
  • [9] Wear of metal-on-metal hip bearings: metallurgical considerations after hip simulator studies
    Affatato, Saverio
    Traina, Francesco
    Ruggeri, Oddone
    Toni, Aldo
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (12) : 1155 - 1164
  • [10] Ceramic-On-Metal for Total Hip Replacement: Mixing and Matching Can Lead to High Wear
    Affatato, Saverio
    Spinelli, Michele
    Zavalloni, Mara
    Traina, Francesco
    Carmignato, Simone
    Toni, Aldo
    [J]. ARTIFICIAL ORGANS, 2010, 34 (04) : 319 - 323