Reference Standard Test and the Diagnostic Ability of Spectral Domain Optical Coherence Tomography in Glaucoma

被引:5
作者
Rao, Harsha L. [1 ,2 ]
Yadav, Ravi K. [1 ]
Addepalli, Uday K. [1 ]
Begum, Viquar U. [1 ]
Senthil, Sirisha [1 ]
Choudhari, Nikhil S. [1 ]
Garudadri, Chandra S. [1 ]
机构
[1] VST Glaucoma Ctr, Hyderabad, Andhra Pradesh, India
[2] LV Prasad Eye Inst, Ctr Clin Epidemiol & Biostat, Hyderabad 500034, Andhra Pradesh, India
关键词
glaucoma; spectral domain optical coherence tomography; visual fields; NERVE-FIBER LAYER; PREPERIMETRIC GLAUCOMA; AUTOMATED PERIMETRY; CIRRUS HD; ACCURACY; DISC; BIAS; RESOLUTION; AGREEMENT; DEFECTS;
D O I
10.1097/IJG.0000000000000087
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To evaluate the relationship between the reference standard used to diagnose glaucoma and the diagnostic ability of spectral domain optical coherence tomograph (SDOCT).Methods:In a cross-sectional study, 280 eyes of 175 consecutive subjects, referred to a tertiary eye care center for glaucoma evaluation, underwent optic disc photography, visual field (VF) examination, and SDOCT examination. The cohort was divided into glaucoma and control groups based on 3 reference standards for glaucoma diagnosis: first based on the optic disc classification (179 glaucoma and 101 control eyes), second on VF classification (glaucoma hemifield test outside normal limits and pattern SD with P-value of <5%, 130 glaucoma and 150 control eyes), and third on the presence of both glaucomatous optic disc and glaucomatous VF (125 glaucoma and 155 control eyes). Relationship between the reference standards and the diagnostic parameters of SDOCT were evaluated using areas under the receiver operating characteristic curve, sensitivity, and specificity.Results:Areas under the receiver operating characteristic curve and sensitivities of most of the SDOCT parameters obtained with the 3 reference standards (ranging from 0.74 to 0.88 and 72% to 88%, respectively) were comparable (P>0.05). However, specificities of SDOCT parameters were significantly greater (P<0.05) with optic disc classification as reference standard (74% to 88%) compared with VF classification as reference standard (57% to 74%).Conclusions:Diagnostic parameters of SDOCT that was significantly affected by reference standard was the specificity, which was greater with optic disc classification as the reference standard. This has to be considered when comparing the diagnostic ability of SDOCT across studies.
引用
收藏
页码:E151 / E156
页数:6
相关论文
共 39 条
  • [1] ABRAMS LS, 1994, OPHTHALMOLOGY, V101, P1662
  • [2] Distribution-free ROC analysis using binary regression techniques
    Alonzo, TA
    Pepe, MS
    [J]. BIOSTATISTICS, 2002, 3 (03) : 421 - 432
  • [3] Anderson D R., 1999, Automated Static Perimetry, V2nd, P152
  • [4] The Applicability of Ganglion Cell Complex Parameters Determined From SD-OCT Images to Detect Glaucomatous Eyes
    Arintawati, Paramastri
    Sone, Takashi
    Akita, Tomoyuki
    Tanaka, Junko
    Kiuchi, Yoshiaki
    [J]. JOURNAL OF GLAUCOMA, 2013, 22 (09) : 713 - 718
  • [5] Sensitivity and Specificity of Time-Domain versus Spectral-Domain Optical Coherence Tomography in Diagnosing Early to Moderate Glaucoma
    Chang, Robert T.
    Knight, O'Rese J.
    Feuer, William J.
    Budenz, Donald L.
    [J]. OPHTHALMOLOGY, 2009, 116 (12) : 2294 - 2299
  • [6] Coleman AFD, 2004, THE HAGUE, P9
  • [7] COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH
    DELONG, ER
    DELONG, DM
    CLARKEPEARSON, DI
    [J]. BIOMETRICS, 1988, 44 (03) : 837 - 845
  • [8] Sources of bias in studies of optic disc and retinal nerve fibre layer morphology
    Garway-Heath, DF
    Hitchings, RA
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (09) : 986 - 986
  • [9] Neural losses correlated with visual losses in clinical perimetry
    Harwerth, RS
    Carter-Dawson, L
    Smith, EL
    Barnes, G
    Holt, WF
    Crawford, MLJ
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (09) : 3152 - 3160
  • [10] Frequency-doubling technology and retinal measurements with spectral-domain optical coherence tomography in preperimetric glaucoma
    Hirashima, Takafumi
    Hangai, Masanori
    Nukada, Masayuki
    Nakano, Noriko
    Morooka, Satoshi
    Akagi, Tadamichi
    Nonaka, Atsushi
    Yoshimura, Nagahisa
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (01) : 129 - 137