24-Hour Intraocular Pressure of Young Healthy Humans in Supine Position: Rhythm and Reproducibility

被引:22
作者
Mottet, Benjamin [1 ,2 ]
Chiquet, Christophe [1 ,2 ]
Aptel, Florent [1 ]
Noel, Christian [1 ]
Gronfier, Claude [3 ]
Buguet, Alain [4 ]
Romanet, Jean-Paul [1 ]
机构
[1] Univ Hosp Grenoble, Dept Ophthalmol, F-38043 Grenoble, France
[2] Univ Grenoble 1, INSERM, U1042, Lab Hypoxia & Physiopathol, Grenoble, France
[3] Stem Cell & Brain Res Inst, Dept Chronobiol, Bron, France
[4] CRSSA, La Tronche, France
关键词
NOCTURNAL ELEVATION; INDIVIDUALS; RABBITS; PATTERN; ADULTS; EYE; TELEMETRY; MODERATE;
D O I
10.1167/iovs.12-10877
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. We evaluated the supine 24-hour IOP rhythm reproducibility over 6 weeks in healthy humans. METHODS. Six healthy young male subjects underwent six 24-hour sessions of IOP measurements over a 6-week period. Subjects were housed in a sleep laboratory in a constant controlled supine position and in a strictly controlled environment. IOP was measured hourly using a pneumatonometer. A nonlinear least-squares dual harmonic regression analysis was used to model the 24-hour IOP rhythm. The intra- and intersubject variability of acrophase, bathyphase, amplitude, and IOP values were evaluated. RESULTS. A significant nyctohemeral IOP rhythm was noted in 30 of 36 (83%) sessions. Mean nocturnal IOP was significantly higher than diurnal IOP (20.1 +/- 0.2 mm Hg [SD] vs. 18.8 +/- 0.1 mm Hg, P < 0.001) in all subjects. Amplitudes were not statistically different among subjects (P = 0.52). In contrast, acrophase and bathyphase were statistically different (P < 0.05). Intrasubject homogeneity of distribution over time of the acrophase and bathyphase was significant in 3 of 6 and 4 of 6 subjects, respectively. Intraclass correlation coefficients of midline estimating statistic of rhythm (MESOR) and IOP values at 2: 00, 3: 00, 4: 00, 10: 00, and 11: 00 AM, and 2: 00 PM showed fair to good agreement among sessions. CONCLUSIONS. In a constant supine position, all subjects exhibited a nyctohemeral IOP rhythm present at an average rate of 80% of all sessions. With the currently available methods of tonometry, intrasubject reproducibility of rhythmic parameters and IOP values is limited. IOP values in the morning and IOP MESOR were the most reproducible parameters among the six visits. (Invest Ophthalmol Vis Sci. 2012; 53: 8186-8191) DOI:10.1167/iovs.12-10877
引用
收藏
页码:8186 / 8191
页数:6
相关论文
共 50 条
  • [1] Asymmetry of Habitual 24-Hour Intraocular Pressure Rhythm in Glaucoma Patients
    Liu, John H. K.
    Weinreb, Robert N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (11) : 7398 - 7402
  • [2] The Effect of Lateral Decubitus Position on Nocturnal Intraocular Pressure over a Habitual 24-Hour Period in Healthy Adults
    Hao, Jie
    Zhen, Yi
    Wang, Hao
    Yang, Diya
    Wang, Ningli
    PLOS ONE, 2014, 9 (11):
  • [3] Disruption of 24-Hour Rhythm in Intraocular Pressure Correlates with Retinal Ganglion Cell Loss in Glaucoma
    Neroev, Vladimir
    Malishevskaya, Tatyana
    Weinert, Dietmar
    Astakhov, Sergei
    Kolomeichuk, Sergey
    Cornelissen, Germaine
    Kabitskaya, Yana
    Boiko, Elena
    Nemtsova, Irina
    Gubin, Denis
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2021, 22 (01) : 1 - 18
  • [4] Is 24-hour Intraocular Pressure Monitoring Necessary in Glaucoma?
    Mansouri, Kaweh
    Weinreb, Robert N.
    Medeiros, Felipe A.
    SEMINARS IN OPHTHALMOLOGY, 2013, 28 (03) : 157 - 164
  • [5] 24-hour Intraocular Pressure Fluctuation Monitoring Using an Ocular Telemetry Sensor: Tolerability and Functionality in Healthy Subjects
    De Smedt, Stefan
    Mermoud, Andre
    Schnyder, Corinne
    JOURNAL OF GLAUCOMA, 2012, 21 (08) : 539 - 544
  • [6] 24-Hour Intra::ular Pressure Rhythm in Young Healthy Subjects Evaluated With Continuous Monitoring Using a Contact Lens Suisor
    Mottet, Benjamin
    Aptel, Florent
    Romanet, Jean-Paul
    Hubanova, Ralitsa
    Pepin, Jean-Louis
    Chiquet, Christophe
    JAMA OPHTHALMOLOGY, 2013, 131 (12) : 1507 - 1516
  • [7] Hourly Awakening vs Continuous Contact Lens Sensor Measurements of 24-Hour Intraocular Pressure Effect on Sleep Macrostructure and Intraocular Pressure Rhythm
    Aptel, Florent
    Tamisier, Renaud
    Pepin, Jean-Louis
    Mottet, Benjamin
    Hubanova, Ralitsa
    Romanet, Jean-Paul
    Chiquet, Christophe
    JAMA OPHTHALMOLOGY, 2014, 132 (10) : 1232 - 1238
  • [8] 24-Hour Measurement of Intraocular Pressure in Guinea Pigs (Cavia porcellus)
    Ansari-Mood, Maneli
    Mehdi-Rajaei, Seyed
    Sadjadi, Reza
    Selk-Ghaffari, Masoud
    Williams, David L.
    JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE, 2016, 55 (01): : 95 - 97
  • [9] 24-hour "intraocular pressure" measurement with sensory contact lens Triggerfish: from euphoria to disillusion
    Faschinger, C.
    Mossboeck, G.
    Strohmaier, C.
    Reitsamer, H. A.
    SPEKTRUM DER AUGENHEILKUNDE, 2011, 25 (04) : 262 - 268
  • [10] Influence of Ocular Dimensional Change on 24-Hour Intraocular Pressure Measurement With Contact Lens Sensor
    Tojo, Naoki
    Hayashi, Atsushi
    JOURNAL OF GLAUCOMA, 2019, 28 (09) : 808 - 810