Metabolornic analysis of urine samples by UHPLC-QTOF-MS: Impact of normalization strategies

被引:132
作者
Gagnebin, Yoric [1 ]
Tonoli, David [1 ,2 ,3 ]
Lescuyer, Pierre [4 ]
Ponte, Belen [5 ]
de Seigneux, Sophie [5 ]
Martin, Pierre-Yves [5 ]
Schappler, Julie [1 ]
Boccard, Julien [1 ]
Rudaz, Serge [1 ,2 ,3 ]
机构
[1] Univ Lausanne, Univ Geneva, Sch Pharmaceut Sci, Geneva, Switzerland
[2] Univ Basel, SCAHT, Basel, Switzerland
[3] Univ Geneva, SCAHT, Basel, Switzerland
[4] Geneva Univ Hosp HUG, Dept Genet & Lab Med, Geneva, Switzerland
[5] Geneva Univ Hosp HUG, Serv Nephrol, Geneva, Switzerland
关键词
Metabolomics; LC-MS; Urine; Normalization; Kidney failure; CHROMATOGRAPHY-MASS-SPECTROMETRY; INFORMATION RECOVERY; QUALITY-CONTROL; LARGE-SCALE; BIOMARKERS; CANCER; CREATININE; PROFILES;
D O I
10.1016/j.aca.2016.12.029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Among the various biological matrices used in metabolomics, urine is a biofluid of major interest because of its non-invasive collection and its availability in large quantities. However, significant sources of variability in urine metabolomics based on UHPLC-MS are related to the analytical drift and variation of the sample concentration, thus requiring normalization. A sequential normalization strategy was developed to remove these detrimental effects, including: (i) pre-acquisition sample normalization by individual dilution factors to narrow the concentration range and to standardize the analytical conditions, (ii) post-acquisition data normalization by quality control based robust LOESS signal correction (QC-RLSC) to correct for potential analytical drift, and (iii) post-acquisition data normalization by MS total useful signal (MSTUS) or probabilistic quotient normalization (PQN) to prevent the impact of concentration variability. This generic strategy was performed with urine samples from healthy individuals and was further implemented in the context of a clinical study to detect alterations in urine metabolomic profiles due to kidney failure. In the case of kidney failure, the relation between creatinine/osmolality and the sample concentration is modified, and relying only on these measurements for normalization could be highly detrimental. The sequential normalization strategy was demonstrated to significantly improve patient stratification by decreasing the unwanted variability and thus enhancing data quality. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:27 / 35
页数:9
相关论文
共 29 条
  • [1] Searching for urine biomarkers of bladder cancer recurrence using a liquid chromatography-mass spectrometry and capillary electrophoresis-mass spectrometry metabolomics approach
    Alberice, Juliana Vieira
    Amaral, Andre F. S.
    Grace Armitage, Emily
    Antonio Lorente, Jose
    Algaba, Ferran
    Carrilho, Emanuel
    Marquez, Mirari
    Garcia, Antonia
    Malats, Nuria
    Barbas, Coral
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2013, 1318 : 163 - 170
  • [2] Measurement of urinary concentration: a critical appraisal of methodologies
    Chadha, V
    Garg, U
    Alon, US
    [J]. PEDIATRIC NEPHROLOGY, 2001, 16 (04) : 374 - 382
  • [3] Combination of Injection Volume Calibration by Creatinine and MS Signals' Normalization to Overcome Urine Variability in LC-MS-Based Metabolomics Studies
    Chen, Yanhua
    Shen, Guoqing
    Zhang, Ruiping
    He, Jiuming
    Zhang, Yi
    Xu, Jing
    Yang, Wei
    Chen, Xiaoguang
    Song, Yongmei
    Abliz, Zeper
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (16) : 7659 - 7665
  • [4] Assessment of data pre-processing methods for LC-MS/MS-based metabolomics of uterine cervix cancer
    Chen, Yanhua
    Xu, Jing
    Zhang, Ruiping
    Shen, Guoqing
    Song, Yongmei
    Sun, Jianghao
    He, Jiuming
    Zhan, Qimin
    Abliz, Zeper
    [J]. ANALYST, 2013, 138 (09) : 2669 - 2677
  • [5] Use of a pre-analysis osmolality normalisation method to correct for variable. urine concentrations and for improved metabolomic analyses
    Chetwynd, Andrew J.
    Abdul-Sada, Alaa
    Holt, Stephen G.
    Hill, Elizabeth M.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2016, 1431 : 103 - 110
  • [6] Dunn WB, 2012, BIOANALYSIS, V4, P2249, DOI [10.4155/BIO.12.204, 10.4155/bio.12.204]
  • [7] Procedures for large-scale metabolic profiling of serum and plasma using gas chromatography and liquid chromatography coupled to mass spectrometry
    Dunn, Warwick B.
    Broadhurst, David
    Begley, Paul
    Zelena, Eva
    Francis-McIntyre, Sue
    Anderson, Nadine
    Brown, Marie
    Knowles, Joshau D.
    Halsall, Antony
    Haselden, John N.
    Nicholls, Andrew W.
    Wilson, Ian D.
    Kell, Douglas B.
    Goodacre, Royston
    [J]. NATURE PROTOCOLS, 2011, 6 (07) : 1060 - 1083
  • [8] MetMSLine: an automated and fully integrated pipeline for rapid processing of high-resolution LC-MS metabolomic datasets
    Edmands, William M. B.
    Barupal, Dinesh K.
    Scalbert, Augustin
    [J]. BIOINFORMATICS, 2015, 31 (05) : 788 - 790
  • [9] Normalization to Specific Gravity Prior to Analysis Improves Information Recovery from High Resolution Mass Spectrometry Metabolomic Profiles of Human Urine
    Edmands, William M. B.
    Ferrari, Pietro
    Scalbert, Augustin
    [J]. ANALYTICAL CHEMISTRY, 2014, 86 (21) : 10925 - 10931
  • [10] What can go wrong at the data normalization step for identification of biomarkers?
    Filzmoser, P.
    Walczak, B.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2014, 1362 : 194 - 205