Posterior Border Distance: An Effective Diagnostic Measurement for Carpal Tunnel Syndrome Using Ultrasonography

被引:0
|
作者
Meric, Gokhan [1 ]
Basdelioglu, Koray [2 ]
Yanik, Bahar [3 ]
Sargin, Serdar [4 ]
Ulusal, Ali Engin [4 ]
机构
[1] Yeditepe Univ, Orthopaed & Traumatol, Istanbul, Turkey
[2] Istanbul Oncol Hosp, Orthoped & Traumatol, Istanbul, Turkey
[3] Balikesir Univ, Radiol, Balikesir, Turkey
[4] Balikesir Univ, Orthopaed & Traumatol, Balikesir, Turkey
关键词
carpal tunnel syndrome; posterior border distance; ultrasonography; electrodiagnostic test; NERVE-CONDUCTION; SONOGRAPHY; RATIO; AREA;
D O I
10.7759/cureus.11010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose The purpose of this study was to define posterior border distance (PBD), which represents an ultrasonographic diagnosing method of carpal tunnel syndrome (CTS), and to determine the reliability of PBD in comparison with electromyography (EMG) results. Methods Thirty-three patients (mean age: 51.8 +/- 9.5 years; 27 females and six males) with CTS were included in this study. Ultrasonography (US) and EMG were performed under blinded conditions. PBD was evaluated by measuring the length of the perpendicular line between the posterior border of the median nerve and the line between the hook of the hamate and trapezoid tubercle. The cross-sectional area, anteroposterior (AP), and transverse diameter of the median nerve were measured. Control US was performed in 20 patients who were available at the first year postoperative follow-up and the results compared with preoperative US values. Correlation analyzes were performed to determine the relationship between electrodiagnostic results and ultrasonographic measurements. Results According to the results of preoperative and postoperative first-year US, there were statistically significant differences in the results of PBD (preoperative: 3.309 +/- 1.7472 mm, postoperative: 2.290 +/- 0.7867 mm p: 0.013) and AP diameter of the median nerve (preoperative: 3.012 +/- 0.7865 mm, postoperative: 2.680 +/- 0,5578 mm p: 0.017). There was no statistically significant difference in transverse diameter (preoperative: 6.585 +/- 1.9505 mm, postoperative: 6.955 +/- 2.2128 mm) and cross-sectional area (preoperative: 14.33 +/- 6.513 mm(2), postoperative: 11.20 +/- 5.830 mm(2)) results (p>0.05). The cut-off value of PBD was >= 3.6 mm, it yielded 81.48% specificity and 83.33% sensitivity in the diagnosis of CTS. PBD was correlated with motor and sensory latency, anteromedial, and transverse diameter of the median nerve (p<0.05). There was no correlation between EMG values and the results of the cross-sectional area, transverse diameter, and AP diameter of the median nerve (p>0.05). Conclusion PBD is suggested as a reliable ultrasonographic measurement method for the diagnosis of CTS.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Gray Scale Histogram Analysis of Carpal Tunnel Syndrome with Ultrasonography
    Umay, Sermin Tok
    Analan, Pinar Doruk
    CURRENT MEDICAL IMAGING REVIEWS, 2019, 15 (03) : 334 - 337
  • [22] Screening of Axonal Degeneration in Carpal Tunnel Syndrome Using Ultrasonography and Nerve Conduction Studies
    Deng, Xue
    Chau, Lai-Heung Phoebe
    Chiu, Suk-Yee
    Leung, Kwok-Pui
    Hu, Yong
    Ip, Wing-Yuk
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (143):
  • [23] Emerging role of ultrasonography in the diagnosis of carpal tunnel syndrome: Relation to risk factors, clinical and electrodiagnostic severity
    El-Najjar, Amany R.
    Abu-Elsoaud, Amany M.
    Sabbah, Dina A.
    Zeid, Ayman F.
    EGYPTIAN RHEUMATOLOGIST, 2021, 43 (04) : 341 - 345
  • [24] The diagnostic accuracy of median nerve ultrasonography in elderly patients with carpal tunnel syndrome: sensitivity and specificity assessment
    Roghani, Reza Salman
    Hashemi, Seyed Ebrahim
    Holisaz, Mohammad Taghi
    Gohari, Faeze
    Delbari, Ahmad
    Lokk, Johan
    CLINICAL INTERVENTIONS IN AGING, 2018, 13 : 1953 - 1962
  • [25] Severity of Carpal tunnel syndrome assessed with high frequency ultrasonography
    Karadag, Yesim Suecuellue
    Karadag, Omer
    Cicekli, Esen
    Ozturk, Serefnur
    Kiraz, Sedat
    Ozbakir, Senay
    Filippucci, Emilio
    Grassi, Walter
    RHEUMATOLOGY INTERNATIONAL, 2010, 30 (06) : 761 - 765
  • [26] The diagnostic value of ultrasonography in carpal tunnel syndrome: a comparison between diabetic and non-diabetic patients
    Tsai, Nai-Wen
    Lee, Lian-Hui
    Huang, Chi-Ren
    Chang, Wen-Neng
    Wang, Hung-Chen
    Lin, Yu-Jun
    Lin, Wei-Che
    Lin, Tsu-Kung
    Cheng, Ben-Chung
    Su, Yu-Jih
    Kung, Chia-Te
    Chen, Shu-Fang
    Lu, Cheng-Hsien
    BMC NEUROLOGY, 2013, 13
  • [27] ULTRASONOGRAPHY FOR DIAGNOSING CARPAL TUNNEL SYNDROME: A META-ANALYSIS OF DIAGNOSTIC TEST ACCURACY
    Tai, Ta-Wei
    Wu, Cheng-Yi
    Su, Fong-Chin
    Chern, Tai-Chang
    Jou, I-Ming
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (07) : 1121 - 1128
  • [28] Diagnostic pitfalls in carpal tunnel syndrome
    Petiot, P.
    Bernard, E.
    REVUE NEUROLOGIQUE, 2011, 167 (01) : 64 - 71
  • [29] Value of Ultrasonography in the Diagnosis of Carpal Tunnel Syndrome : Correlation with Electrophysiological Abnormalities and Clinical Severity
    Kim, Min-Kyu
    Jeon, Hong-Jun
    Park, Se-Hyuck
    Park, Dong-Sik
    Nam, Hee-Seung
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2014, 55 (02) : 78 - 82
  • [30] The controversy of the normal values of ultrasonography in carpal tunnel syndrome: diagnostic accuracy of wrist-dependent CSA revisited
    De Kleermaeker, Floriaan G. C. M.
    Meulstee, Jan
    Verhagen, Wim I. M.
    NEUROLOGICAL SCIENCES, 2019, 40 (05) : 1041 - 1047