Posterior Border Distance: An Effective Diagnostic Measurement for Carpal Tunnel Syndrome Using Ultrasonography

被引:0
|
作者
Meric, Gokhan [1 ]
Basdelioglu, Koray [2 ]
Yanik, Bahar [3 ]
Sargin, Serdar [4 ]
Ulusal, Ali Engin [4 ]
机构
[1] Yeditepe Univ, Orthopaed & Traumatol, Istanbul, Turkey
[2] Istanbul Oncol Hosp, Orthoped & Traumatol, Istanbul, Turkey
[3] Balikesir Univ, Radiol, Balikesir, Turkey
[4] Balikesir Univ, Orthopaed & Traumatol, Balikesir, Turkey
关键词
carpal tunnel syndrome; posterior border distance; ultrasonography; electrodiagnostic test; NERVE-CONDUCTION; SONOGRAPHY; RATIO; AREA;
D O I
10.7759/cureus.11010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose The purpose of this study was to define posterior border distance (PBD), which represents an ultrasonographic diagnosing method of carpal tunnel syndrome (CTS), and to determine the reliability of PBD in comparison with electromyography (EMG) results. Methods Thirty-three patients (mean age: 51.8 +/- 9.5 years; 27 females and six males) with CTS were included in this study. Ultrasonography (US) and EMG were performed under blinded conditions. PBD was evaluated by measuring the length of the perpendicular line between the posterior border of the median nerve and the line between the hook of the hamate and trapezoid tubercle. The cross-sectional area, anteroposterior (AP), and transverse diameter of the median nerve were measured. Control US was performed in 20 patients who were available at the first year postoperative follow-up and the results compared with preoperative US values. Correlation analyzes were performed to determine the relationship between electrodiagnostic results and ultrasonographic measurements. Results According to the results of preoperative and postoperative first-year US, there were statistically significant differences in the results of PBD (preoperative: 3.309 +/- 1.7472 mm, postoperative: 2.290 +/- 0.7867 mm p: 0.013) and AP diameter of the median nerve (preoperative: 3.012 +/- 0.7865 mm, postoperative: 2.680 +/- 0,5578 mm p: 0.017). There was no statistically significant difference in transverse diameter (preoperative: 6.585 +/- 1.9505 mm, postoperative: 6.955 +/- 2.2128 mm) and cross-sectional area (preoperative: 14.33 +/- 6.513 mm(2), postoperative: 11.20 +/- 5.830 mm(2)) results (p>0.05). The cut-off value of PBD was >= 3.6 mm, it yielded 81.48% specificity and 83.33% sensitivity in the diagnosis of CTS. PBD was correlated with motor and sensory latency, anteromedial, and transverse diameter of the median nerve (p<0.05). There was no correlation between EMG values and the results of the cross-sectional area, transverse diameter, and AP diameter of the median nerve (p>0.05). Conclusion PBD is suggested as a reliable ultrasonographic measurement method for the diagnosis of CTS.
引用
收藏
页数:6
相关论文
共 50 条
  • [11] Diagnostic Significance of Ultrasonography in Carpal Tunnel Syndrome and Comparison with Electrodiagnostic Tests
    Saracgil, Sacide Nur
    Karatas, Metin
    Yerli, Hasan
    Isiklar, Iclal
    Karadeli, Elif
    TURKIYE FIZIKSEL TIP VE REHABILITASYON DERGISI-TURKISH JOURNAL OF PHYSICAL MEDICINE AND REHABILITATION, 2009, 55 (01): : 13 - 18
  • [12] The usefulness of ultrasonography to diagnose the early stage of carpal tunnel syndrome in proximal to the carpal tunnel inlet A prospective study
    Bang, Myeonghwan
    Kim, Jong Moon
    Kim, Hyoung Seop
    MEDICINE, 2019, 98 (26) : e16039
  • [13] The Nerve/Tunnel Index: A New Diagnostic Standard for Carpal Tunnel Syndrome Using Sonography A Not Study
    Kim, Hyoung Seop
    Joo, Seung Ho
    Han, Zee-A
    Kim, Yong Wook
    JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (01) : 23 - 29
  • [14] Ultrasonography in severe carpal tunnel syndrome
    Kasius, Kristel M.
    Claes, Franka
    Verhagen, Wim Im
    Meulstee, Jan
    MUSCLE & NERVE, 2012, 45 (03) : 334 - 337
  • [15] IDIOPATHIC CARPAL TUNNEL SYNDROME: EVALUATION OF THE DEPTH OF THE CARPAL TUNNEL BY ULTRASONOGRAPHY
    Elsaman, Ahmed Mohammed Mahrous Yousif
    Thabit, Mohamed Nasreldin
    Radwan, Ahmed Roshdy Al-Agamy
    Ohrndorf, Sarah
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (11) : 2827 - 2835
  • [16] Ultrasonography Findings of the Carpal Tunnel after Endoscopic Carpal Tunnel Release for Carpal Tunnel Syndrome
    Ng, Alex Wing Hung
    Griffith, James Francis
    Tsoi, Carita
    Fong, Raymond Chun Wing
    Mak, Michael Chu Kay
    Tse, Wing Lim
    Ho, Pak Cheong
    KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (07) : 1132 - 1141
  • [17] DIAGNOSIS OF SEVERE CARPAL TUNNEL SYNDROME USING NERVE CONDUCTION STUDY AND ULTRASONOGRAPHY
    Fujimoto, Kazuhiro
    Kanchiku, Tsukasa
    Kido, Kenji
    Imajo, Yasuaki
    Funaba, Masahiro
    Taguchi, Toshihiko
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (10) : 2575 - 2580
  • [18] Carpal tunnel syndrome. The contribution of ultrasonography
    Manuel Pardal-Fernandez, Jose
    REVISTA DE NEUROLOGIA, 2014, 59 (10) : 459 - 469
  • [19] Ultrasonography of Median Nerve and Electrophysiologic Severity in Carpal Tunnel Syndrome
    Kang, Seok
    Kwon, Hee Kyu
    Kim, Ki Hoon
    Yun, Hyung Seok
    ANNALS OF REHABILITATION MEDICINE-ARM, 2012, 36 (01): : 72 - 79
  • [20] The usefulness of ultrasonography in the diagnosis of carpal tunnel syndrome
    Pinilla, I.
    Martin-Hervas, C.
    Sordo, G.
    Santiago, S.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2008, 33E (04) : 435 - 439