Reproducibility of human cardiac phosphorus MRS (31P-MRS) at 7 T

被引:19
|
作者
Ellis, Jane [1 ]
Valkovic, Ladislav [1 ,2 ]
Purvis, Lucian A. B. [1 ]
Clarke, William T. [1 ,3 ]
Rodgers, Christopher T. [1 ,4 ]
机构
[1] Univ Oxford, RDM Cardiovasc Med, OCMR, Oxford, England
[2] Slovak Acad Sci, Inst Measurement Sci, Bratislava, Slovakia
[3] Univ Oxford, Nuffield Dept Clin Neurosci, FMRIB, Wellcome Ctr Integrat Neuroimaging, Oxford, England
[4] Univ Cambridge, Dept Clin Neurosci, Wolfson Brain Imaging Ctr, Cambridge, England
基金
英国医学研究理事会; 英国惠康基金;
关键词
P-31; 7; T; cardiac; human; MRS; reproducibility; MAGNETIC-RESONANCE-SPECTROSCOPY; ENERGY PHOSPHATE METABOLITES; CORONARY-ARTERY-DISEASE; DILATED CARDIOMYOPATHY; IN-VIVO; HEART; QUANTIFICATION; MYOCARDIUM;
D O I
10.1002/nbm.4095
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Purpose We test the reproducibility of human cardiac phosphorus MRS (P-31-MRS) at ultra-high field strength (7 T) for the first time. The primary motivation of this work was to assess the reproducibility of a 'rapid' 61/2 min P-31 three-dimensional chemical shift imaging (3D-CSI) sequence, which if sufficiently reproducible would allow the study of stress-response processes. We compare this with an established 28 min protocol, designed to record high-quality spectra in a clinically feasible scan time. Finally, we use this opportunity to compare the effect of per-subject B-0 shimming on data quality and reproducibility in the 61/2 min protocol. Methods 10 healthy subjects were scanned on two occasions: one to test the 28 min 3D-CSI protocol, and one to test the 61/2 min protocol. Spectra were fitted using the OXSA MATLAB toolbox. The phosphocreatine to adenosine triphosphate concentration ratio (PCr/ATP) from each scan was analysed for intra- and intersubject variability. The impact of different strategies for voxel selection was assessed. Results There were no significant differences between repeated measurements in the same subject. For the 28 min protocol, PCr/ATP in the midseptal voxel across all scans was 1.91 +/- 0.36 (mean +/- intersubject SD). For the 61/2 min protocol, PCr/ATP in the midseptal voxel was 1.76 +/- 0.40. The coefficients of reproducibility (CRs) were 0.49 (28 min) and 0.67 (61/2 min). Per-subject B-0 shimming improved the fitted PCr/ATP precision (for 61/2 min scans), but had negligible effect on the CR (0.67 versus 0.66). Conclusions Both 7 T protocols show improved reproducibility compared with a previous 3 T study by Tyler et al. Our results will enable informed power calculations and protocol selection for future clinical research studies.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Abnormal Bioenergetics in Schizophrenia and Bipolar Disorders Studied by Dynamic 31P-MRS
    Du, Fei
    Yuksel, Cagri
    Lukas, Scott
    Cohen, Bruce
    Ongur, Dost
    NEUROPSYCHOPHARMACOLOGY, 2013, 38 : S124 - S125
  • [42] Mitochondrial dysfunction in bipolar disorder:: From 31P-MRS to molecular genetics
    Kato, T.
    INTERNATIONAL JOURNAL OF NEUROPSYCHOPHARMACOLOGY, 2006, 9 : S83 - S83
  • [43] 31P-MRS of skeletal muscle is not a sensitive diagnostic test for mitochondrial myopathy
    Tina Dysgaard Jeppesen
    Bjørn Quistorff
    Flemming Wibrand
    John Vissing
    Journal of Neurology, 2007, 254 : 29 - 37
  • [44] 31P-MRS of healthy human brain: ATP synthesis, metabolite concentrations, pH, and T1 relaxation times
    Ren, Jimin
    Sherry, A. Dean
    Malloy, Craig R.
    NMR IN BIOMEDICINE, 2015, 28 (11) : 1455 - 1462
  • [45] Human muscle performance and PCr hydrolysis with varied inspired oxygen fractions:: a 31P-MRS study
    Hogan, MC
    Richardson, RS
    Haseler, LJ
    JOURNAL OF APPLIED PHYSIOLOGY, 1999, 86 (04) : 1367 - 1373
  • [46] Combined spiroergometry and 31P-MRS of human calf muscle during high-intensity exercise
    Moll, K.
    Gussew, A.
    Hein, C.
    Stutzig, N.
    Reichenbach, J. R.
    NMR IN BIOMEDICINE, 2017, 30 (07)
  • [47] Retraction Note to: Diagnosis of rejection after liver transplantation: use of phosphorus-31 magnetic resonance spectroscopy (31P-MRS)
    Tao Jiang
    Shiyuan Liu
    XiangSheng Xiao
    XiaoFeng Tao
    GuangHua Liu
    JinLin Wang
    Abdominal Radiology, 2016, 41 : 1876 - 1876
  • [48] USING 31-PHOSPHORUS MAGNETIC RESONANCE SPECTROSCOPY (31P-MRS) TO IDENTIFY PARKINSON'S DISEASE SUBGROUPS WITH BIOENERGETIC DYSFUNCTION
    Payne, Thomas
    Burgess, Toby
    Sassani, Matilde
    Bradley, Stephen
    Roscoe, Sarah
    Reed, Emily
    Wilkinson, Iain D.
    Mortiboys, Heather
    Jenkins, Thomas M.
    Bandmann, Oliver
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2022, 93 (09):
  • [49] Phosphorus magnetic resonance spectroscopy and imaging (31P-MRS/MRSI) as a window to brain and muscle metabolism: A review of the methods
    Santos-Diaz, Alejandro
    Noseworthy, Michael D.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 60 (60)
  • [50] RETRACTED ARTICLE: Diagnosis of rejection after liver transplantation: use of phosphorus-31 magnetic resonance spectroscopy (31P-MRS)
    Tao Jiang
    Shiyuan Liu
    XiangSheng Xiao
    XiaoFeng Tao
    GuangHua Liu
    JinLin Wang
    Abdominal Radiology, 2012, 37 : 788 - 794