Reproducibility of human cardiac phosphorus MRS (31P-MRS) at 7 T

被引:19
|
作者
Ellis, Jane [1 ]
Valkovic, Ladislav [1 ,2 ]
Purvis, Lucian A. B. [1 ]
Clarke, William T. [1 ,3 ]
Rodgers, Christopher T. [1 ,4 ]
机构
[1] Univ Oxford, RDM Cardiovasc Med, OCMR, Oxford, England
[2] Slovak Acad Sci, Inst Measurement Sci, Bratislava, Slovakia
[3] Univ Oxford, Nuffield Dept Clin Neurosci, FMRIB, Wellcome Ctr Integrat Neuroimaging, Oxford, England
[4] Univ Cambridge, Dept Clin Neurosci, Wolfson Brain Imaging Ctr, Cambridge, England
基金
英国医学研究理事会; 英国惠康基金;
关键词
P-31; 7; T; cardiac; human; MRS; reproducibility; MAGNETIC-RESONANCE-SPECTROSCOPY; ENERGY PHOSPHATE METABOLITES; CORONARY-ARTERY-DISEASE; DILATED CARDIOMYOPATHY; IN-VIVO; HEART; QUANTIFICATION; MYOCARDIUM;
D O I
10.1002/nbm.4095
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Purpose We test the reproducibility of human cardiac phosphorus MRS (P-31-MRS) at ultra-high field strength (7 T) for the first time. The primary motivation of this work was to assess the reproducibility of a 'rapid' 61/2 min P-31 three-dimensional chemical shift imaging (3D-CSI) sequence, which if sufficiently reproducible would allow the study of stress-response processes. We compare this with an established 28 min protocol, designed to record high-quality spectra in a clinically feasible scan time. Finally, we use this opportunity to compare the effect of per-subject B-0 shimming on data quality and reproducibility in the 61/2 min protocol. Methods 10 healthy subjects were scanned on two occasions: one to test the 28 min 3D-CSI protocol, and one to test the 61/2 min protocol. Spectra were fitted using the OXSA MATLAB toolbox. The phosphocreatine to adenosine triphosphate concentration ratio (PCr/ATP) from each scan was analysed for intra- and intersubject variability. The impact of different strategies for voxel selection was assessed. Results There were no significant differences between repeated measurements in the same subject. For the 28 min protocol, PCr/ATP in the midseptal voxel across all scans was 1.91 +/- 0.36 (mean +/- intersubject SD). For the 61/2 min protocol, PCr/ATP in the midseptal voxel was 1.76 +/- 0.40. The coefficients of reproducibility (CRs) were 0.49 (28 min) and 0.67 (61/2 min). Per-subject B-0 shimming improved the fitted PCr/ATP precision (for 61/2 min scans), but had negligible effect on the CR (0.67 versus 0.66). Conclusions Both 7 T protocols show improved reproducibility compared with a previous 3 T study by Tyler et al. Our results will enable informed power calculations and protocol selection for future clinical research studies.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Functional and metabolic evaluation of the hypertrophied heart using MRI and 31P-MRS
    Lamb, Hildo J.
    van der Laarse, A.
    Pluim, B. M.
    Beyerbacht, H. P.
    Doornbos, J.
    van der Wall, E. E.
    de Roos, A.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1998, 6 (2-3) : 168 - 170
  • [32] Hypohydration effects on skeletal muscle performance and metabolism:: a 31P-MRS study
    Montain, SJ
    Smith, SA
    Mattot, RP
    Zientara, GP
    Jolesz, FA
    Sawka, MN
    JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (06) : 1889 - 1894
  • [33] Improved reproducibility of dynamic 31P-MRS in the calf muscle during exercise by self-adjusted muscle activity
    Gussew, A.
    Hiepe, P.
    Rzanny, R.
    Reichenbach, J. R.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 : 757 - 760
  • [34] Evaluation Of Muscle Properties By 31P-MRS, 13C-MRS And MRI With A General Clinical MR Device
    Takahashi, Hideyuki
    Homma, Toshiyuki
    Suzuki, Yasuhiro
    Ohiwa, Nao
    Tawara, Noriyuki
    Okuwaki, Toru
    Kawanaka, Kenotaro
    Wada, Masanobu
    Takizawa, Osamu
    Maruyama, Katsuya
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2010, 42 (05): : 823 - 823
  • [35] Compression garments and recovery from eccentric exercise:: A 31P-MRS study
    Trenell, MI
    Rooney, KB
    Sue, CM
    Thompson, CH
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2006, 5 (01) : 106 - 114
  • [36] Muscle energetics changes throughout maturation: a quantitative 31P-MRS analysis
    Tonson, Anne
    Ratel, Sebastien
    Le Fur, Yann
    Vilmen, Christophe
    Cozzone, Patrick J.
    Bendahan, David
    JOURNAL OF APPLIED PHYSIOLOGY, 2010, 109 (06) : 1769 - 1778
  • [37] Bioenergetic impairment in Gulf War illness assessed via 31P-MRS
    Golomb, Beatrice Alexandra
    Han, Jun Hee
    Fung, Alexander
    Berg, Brinton Keith
    Miller, Bruce J.
    Hamilton, Gavin
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [38] Abnormal Bioenergetics in Schizophrenia and Bipolar Disorders Studied by Dynamic 31P-MRS
    Du, Fei
    Yuksel, Abdullah
    Cohen, Bruce
    Oenguer, Dost
    NEUROPSYCHOPHARMACOLOGY, 2014, 39 : S629 - S629
  • [39] 31P-MRS of skeletal muscle is not a sensitive diagnostic test for mitochondrial myopathy
    Jeppesen, Tina Dysgaard
    Quistorff, Bjorn
    Wibrand, Flemming
    Vissing, John
    JOURNAL OF NEUROLOGY, 2007, 254 (01) : 29 - 37
  • [40] Muscle energetics changes throughout maturation: a quantitative 31P-MRS analysis
    Tonson, A.
    Ratel, S.
    Le Fur, Y.
    Cozzone, P.
    Bendahan, D.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2009, 23 : 79 - 80