Reproducibility of human cardiac phosphorus MRS (31P-MRS) at 7 T

被引:20
作者
Ellis, Jane [1 ]
Valkovic, Ladislav [1 ,2 ]
Purvis, Lucian A. B. [1 ]
Clarke, William T. [1 ,3 ]
Rodgers, Christopher T. [1 ,4 ]
机构
[1] Univ Oxford, RDM Cardiovasc Med, OCMR, Oxford, England
[2] Slovak Acad Sci, Inst Measurement Sci, Bratislava, Slovakia
[3] Univ Oxford, Nuffield Dept Clin Neurosci, FMRIB, Wellcome Ctr Integrat Neuroimaging, Oxford, England
[4] Univ Cambridge, Dept Clin Neurosci, Wolfson Brain Imaging Ctr, Cambridge, England
基金
英国医学研究理事会; 英国惠康基金;
关键词
P-31; 7; T; cardiac; human; MRS; reproducibility; MAGNETIC-RESONANCE-SPECTROSCOPY; ENERGY PHOSPHATE METABOLITES; CORONARY-ARTERY-DISEASE; DILATED CARDIOMYOPATHY; IN-VIVO; HEART; QUANTIFICATION; MYOCARDIUM;
D O I
10.1002/nbm.4095
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Purpose We test the reproducibility of human cardiac phosphorus MRS (P-31-MRS) at ultra-high field strength (7 T) for the first time. The primary motivation of this work was to assess the reproducibility of a 'rapid' 61/2 min P-31 three-dimensional chemical shift imaging (3D-CSI) sequence, which if sufficiently reproducible would allow the study of stress-response processes. We compare this with an established 28 min protocol, designed to record high-quality spectra in a clinically feasible scan time. Finally, we use this opportunity to compare the effect of per-subject B-0 shimming on data quality and reproducibility in the 61/2 min protocol. Methods 10 healthy subjects were scanned on two occasions: one to test the 28 min 3D-CSI protocol, and one to test the 61/2 min protocol. Spectra were fitted using the OXSA MATLAB toolbox. The phosphocreatine to adenosine triphosphate concentration ratio (PCr/ATP) from each scan was analysed for intra- and intersubject variability. The impact of different strategies for voxel selection was assessed. Results There were no significant differences between repeated measurements in the same subject. For the 28 min protocol, PCr/ATP in the midseptal voxel across all scans was 1.91 +/- 0.36 (mean +/- intersubject SD). For the 61/2 min protocol, PCr/ATP in the midseptal voxel was 1.76 +/- 0.40. The coefficients of reproducibility (CRs) were 0.49 (28 min) and 0.67 (61/2 min). Per-subject B-0 shimming improved the fitted PCr/ATP precision (for 61/2 min scans), but had negligible effect on the CR (0.67 versus 0.66). Conclusions Both 7 T protocols show improved reproducibility compared with a previous 3 T study by Tyler et al. Our results will enable informed power calculations and protocol selection for future clinical research studies.
引用
收藏
页数:11
相关论文
共 31 条
[1]   Metabolic Modulator Perhexiline Corrects Energy Deficiency and Improves Exercise Capacity in Symptomatic Hypertrophic Cardiomyopathy [J].
Abozguia, Khalid ;
Elliott, Perry ;
McKenna, William ;
Phan, Thanh Trung ;
Nallur-Shivu, Ganesh ;
Ahmed, Ibrar ;
Maher, Abdul R. ;
Kaur, Kulvinder ;
Taylor, Jenny ;
Henning, Anke ;
Ashrafian, Houman ;
Watkins, Hugh ;
Frenneaux, Michael .
CIRCULATION, 2010, 122 (16) :1562-U56
[2]   Human Cardiac 31P-MR Spectroscopy at 3 Tesla Cannot Detect Failing Myocardial Energy Homeostasis during Exercise [J].
Bakermans, Adrianus J. ;
Bazil, Jason N. ;
Nederveen, Aart J. ;
Strijkers, Gustav J. ;
Boekholdt, S. Matthijs ;
Beard, Daniel A. ;
Jeneson, Jeroen A. L. .
FRONTIERS IN PHYSIOLOGY, 2017, 8
[3]   BSE procedure guidelines for the clinical application of stress echocardiography, recommendations for performance and interpretation of stress echocardiography - A report of the British Society of Echocardiography Policy Committee [J].
Becher, H ;
Chambers, J ;
Fox, K ;
Jones, R ;
Leech, GJ ;
Masani, N ;
Monaghan, M ;
More, R ;
Nihoyannopoulos, P ;
Rimington, H ;
Senior, R ;
Warton, G .
HEART, 2004, 90 :23-30
[4]   Absolute concentrations of high-energy phosphate metabolites in normal, hypertrophied, and failing human myocardium measured noninvasively with 31P-SLOOP magnetic resonance spectroscopy [J].
Beer, M ;
Seyfarth, T ;
Sandstede, J ;
Landschütz, W ;
Lipke, C ;
Köstler, H ;
von Kienlin, M ;
Harre, K ;
Hahn, D ;
Neubauer, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (07) :1267-1274
[5]   Exercise-Induced Decrease in Myocardial High-Energy Phosphate Metabolites in Patients With Chagas Heart Disease [J].
Betim Paes Leme, Ana Maria ;
Cury Salemi, Vera Maria ;
Weiss, Robert G. ;
Parga, Jose Rodrigues ;
Ianni, Barbara Maria ;
Mady, Charles ;
Kalil-Filho, Roberto .
JOURNAL OF CARDIAC FAILURE, 2013, 19 (07) :454-460
[6]   ROBUST TESTS FOR EQUALITY OF VARIANCES [J].
BROWN, MB ;
FORSYTHE, AB .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1974, 69 (346) :364-367
[7]   Cramer-Rao bounds: an evaluation tool for quantitation [J].
Cavassila, S ;
Deval, S ;
Huegen, C ;
van Ormondt, D ;
Graveron-Demilly, D .
NMR IN BIOMEDICINE, 2001, 14 (04) :278-283
[8]  
Dass S, 2010, J CARDIOVASC MAGN R, V12, P1
[9]   31P-MR spectroscopic imaging in hypertensive heart disease [J].
Heyne, J. -P. ;
Rzanny, R. ;
Hansch, A. ;
Leder, U. ;
Reichenbach, J. R. ;
Kaiser, W. A. .
EUROPEAN RADIOLOGY, 2006, 16 (08) :1796-1802
[10]   Detection of myocardial disorders by magnetic resonance spectroscopy [J].
Hudsmith, Lucy E. ;
Neubauer, Stefan .
NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2008, 5 (Suppl 2) :S49-S56