Finite element analysis of microneedle insertion into skin

被引:25
作者
Chen, Shuhu [1 ]
Li, Nannan [1 ]
Chen, Jing [1 ]
机构
[1] Peking Univ, Natl Key Lab Micro Nano Fabricat Technol, Inst Microelect, Beijing 100871, Peoples R China
关键词
TITANIUM MICRONEEDLES; MECHANICAL-BEHAVIOR; NEEDLE INSERTION; PREDICTION; SIMULATION; DELIVERY; FORCE;
D O I
10.1049/mnl.2012.0585
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A report is presented on the modelling and verification of microneedle-skin interactions. A nonlinear finite element model based on the micro biomechanical properties of skin was established to simulate a microneedle being inserted into the skin. The deformation of skin and the force-displacement behaviour of the microneedle could be obtained. The accuracy was experimentally verified by measuring the relationship between force and displacements during insertion into mouse skin. With this model, the influences of different geometries on microneedle fracture were discussed, which was useful to optimise the microneedle design.
引用
收藏
页码:1206 / 1209
页数:4
相关论文
共 20 条
[1]   Needle insertion and radioactive seed implantation in human tissues: Simulation and sensitivity analysis [J].
Alterovitz, R ;
Goldberg, K ;
Pouliot, J ;
Taschereau, R ;
Hsu, IC .
2003 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-3, PROCEEDINGS, 2003, :1793-1799
[2]  
[Anonymous], 1990, PHYS PROPERTIES TISS
[3]   The viscoelastic, hyperelastic and scale dependent behaviour of freshly excised individual skin layers [J].
Crichton, Michael L. ;
Donose, Bogdan C. ;
Chen, Xianfeng ;
Raphael, Anthony P. ;
Huang, Han ;
Kendall, Mark A. F. .
BIOMATERIALS, 2011, 32 (20) :4670-4681
[4]   Hollow metal microneedles for insulin delivery to diabetic rats [J].
Davis, SP ;
Martanto, W ;
Allen, MG ;
Prausnitz, MR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (05) :909-915
[5]   Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force [J].
Davis, SP ;
Landis, BJ ;
Adams, ZH ;
Allen, MG ;
Prausnitz, MR .
JOURNAL OF BIOMECHANICS, 2004, 37 (08) :1155-1163
[6]   Interactive simulation of needle insertion models [J].
DiMaio, SP ;
Salcudean, SE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (07) :1167-1179
[7]   Silicon micromachined hollow microneedles for transdermal liquid transport [J].
Gardeniers, HJGE ;
Luttge, R ;
Berenschot, EJW ;
de Boer, MJ ;
Yeshurun, SY ;
Hefetz, M ;
van't Oever, R ;
van den Berg, A .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2003, 12 (06) :855-862
[8]   Biomechanical measurements in microscopically thin stratum corneum using acoustics [J].
Gardner, TN ;
Briggs, GAD .
SKIN RESEARCH AND TECHNOLOGY, 2001, 7 (04) :254-261
[9]   Micromachined electrodes for biopotential measurements [J].
Griss, P ;
Enoksson, P ;
Tolvanen-Laakso, HK ;
Meriläinen, P ;
Ollmar, S ;
Stemme, G .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2001, 10 (01) :10-16
[10]   A numerical-experimental method to characterize the non-linear mechanical behaviour of human skin [J].
Hendriks, FM ;
Brokken, D ;
van Eemeren, JTWM ;
Oomens, CWJ ;
Baaijens, FPT ;
Horsten, JBAM .
SKIN RESEARCH AND TECHNOLOGY, 2003, 9 (03) :274-283