X-ray test for the evaluation of the internal morphology of the seeds of seafortia palm trees

被引:3
|
作者
Sturiao, Walas Permanhane [1 ]
Correa Landgraf, Paulo Roberto [1 ]
Rosa, Thiago Paschoal [1 ]
机构
[1] Univ Jose Rosario Vellano, Inst Ciencias Agr, Alfenas, MG, Brazil
来源
SEMINA-CIENCIAS AGRARIAS | 2012年 / 33卷
关键词
Archontophoenix cunninghamii; image analysis; germination; Australian royal palm;
D O I
10.5433/1679-0359.2012v33Supl1p3003
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
The seafortia palm tree (Archontophoenix cunninghamii) is originally from Australia and is widely used in ornamental gardens in Brazil. Due to the lack of information on the process of obtaining quality seedlings and the market demand for ornamental palms, the objective of this study was to use an x-ray test to evaluate the internal morphology of the seeds of A. cunninghamii. A total of 8 replicates of 25 seeds were submitted to x-ray analysis using the Raicenter RC 300 Plus T equipment; several radiation intensities and times were used. According to the internal morphology observed on the radiographs, the seeds were classified into 4 categories: perfect seeds, seeds with little damage (less than 50% of tissues damaged), seeds with substantial damage (more than 50% of tissues damaged), and embryos not visualized. After the radiography analysis, the seeds were submitted to a germination test for 160 days at a temperature of 30 degrees C using sphagnum as the substrate. Radiographic analysis at an intensity of 37 kVp and x-ray exposure for 0.25 s was sufficient to evaluate to the internal morphology of the seafortia seeds. The results obtained were as follows: 78% perfect seeds, 15% seeds with little damage, 4% seeds with substantial damage, and 3% seeds in which embryos were not observed. Seafortia palm seeds classified as perfect showed a higher percentage of germination, whereas those that had some level of damage tended to show a low physiological quality that was inimical to germination.
引用
收藏
页码:3003 / 3008
页数:6
相关论文
共 50 条
  • [41] DUAL ENERGY X-RAY DENSITOMETER PERFORMANCE EVALUATION TEST PROCEDURES
    WILSON, CR
    MAHESH, M
    JOURNAL OF BONE AND MINERAL RESEARCH, 1992, 7 : S187 - S187
  • [42] X-RAY IRRADIATION TEST OF A MEMS-BASED X-RAY OPTIC
    Ogawa, Tomohiro
    Ezoe, Yuichiro
    Kakiuchi, Takuya
    Ikuta, Masahiro
    Sato, Mayu
    Ohashi, Takaya
    Mitsuishi, Ikuyuki
    Mitsuda, Kazuhisa
    Morishita, Kohei
    Nakajima, Kazuo
    2014 INTERNATIONAL CONFERENCE ON OPTICAL MEMS AND NANOPHOTONICS (OMN), 2014, : 131 - 132
  • [43] X-ray interferometry - Einstein's theory passes x-ray test
    Jones-Bey, HA
    LASER FOCUS WORLD, 2006, 42 (02): : 40 - 42
  • [44] X-ray methods and nondestructive test facilities (to the centenary of X-ray discovery)
    Sosnin, FR
    INDUSTRIAL LABORATORY, 1995, 61 (11): : 664 - 667
  • [45] Reflectivity test method of x-ray optics at the 100-m x-ray test facility
    Zhu, Yuxuan
    Zhao, Zijian
    Hou, Dongjie
    Yang, Yanji
    Yang, Xiongtao
    Zhang, Yifan
    Wu, Kaiji
    Ding, Fei
    Xie, Dong
    Xu, Yupeng
    Wang, Bo
    Wang, Langping
    Wang, Yusa
    EXPERIMENTAL ASTRONOMY, 2024, 58 (03)
  • [46] X-ray test to evaluate the physiological potencial of Platypodium elegans Vog. Seeds (Fabaceae)
    Paradelo Gomes, Kever Bruno
    Mesquita Matos, Juliana Martins
    Martins, Ildeu Soares
    Cristo Martins, Rosana de Carvalho
    SCIENTIA AGROPECUARIA, 2016, 7 (03) : 305 - 311
  • [47] Non-invasive evaluation of hair interior morphology by X-ray microscope
    Kim, Beom Joon
    Kwon, Oh Sang
    Park, Won Seok
    Youn, Hwa Shik
    Choi, Chong Won
    Kim, Kyu Han
    Eun, Hee Chul
    JOURNAL OF DERMATOLOGY, 2006, 33 (11): : 759 - 764
  • [48] X-ray and NMR for nondestructive internal quality evaluation of durian and mangosteen fruits
    Yantarasri, T
    Sornsrivichai, J
    Chen, P
    POSTHARVEST '96 - PROCEEDINGS OF THE INTERNATIONAL POSTHARVEST SCIENCE CONFERENCE, 1998, 464 : 97 - 101
  • [49] X-ray Angiography Perfusion Analysis for the Balloon Occlusion Test of the Internal Carotid Artery
    Asai, Katsunori
    Imamura, Hirotoshi
    Mineharu, Yohei
    Tani, Shoichi
    Adachi, Hidemitsu
    Narumi, Osamu
    Sato, Shinsuke
    Sakai, Chiaki
    Sakai, Nobuyuki
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2015, 24 (07): : 1506 - 1512
  • [50] X-ray evaluation of the knee
    Kalb, RL
    HOSPITAL PRACTICE, 1997, 32 (08): : 103 - 105