Development of a micro gas chromatograph for the analysis of hydrogen isotope gas mixtures in the fusion fuel cycle

被引:25
作者
Kawamura, Y [1 ]
Konishi, S [1 ]
Nishi, V [1 ]
机构
[1] Japan Atom Res Inst, Tritium Engn Lab, Dept Fus Engn Res, Tokai, Ibaraki 3191195, Japan
关键词
hydrogen isotope; gas chromatography; fusion reactor; retention time;
D O I
10.1016/S0920-3796(01)00378-7
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Analysis of hydrogen isotopes is very important in the fuel cycle system of fusion reactors. Gas chromatography with a cryogenic separation column is one of the most extensively used methods for the analysis of hydrogen isotopes. Micro gas chromatograph (micro GC) with a cryogenic column is expected to improve the analysis time, that is a major disadvantage of conventional GC. The present authors have modified the micro GC to use its separation column at cryogenic temperature. In previous work a micro packed column has been tested and indicated fairly good performance. In this work a capillary column was tested at cryogenic temperature for more improvement of analysis time. Obtained retention time of H(2), HD and D(2) were about 43, 47 and 5.4 s, respectively, for the column with 0.53 mm of I.D., 4.0 m of length and 0.08 mm of film thickness. Peak resolution between H(2) and HD was about 1.12. These results suggest that the column developed in this work attained the practical level for the separation and short analysis time. The estimation of the retention time was carried out using the dispersion model. The retention times of HT, DT and T(2) were also estimated using the reduced. mass. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:389 / 394
页数:6
相关论文
共 6 条
[1]   Analysis of hydrogen isotopes with a micro gas chromatograph [J].
Kawamura, Y ;
Iwai, Y ;
Yamanishi, T ;
Konishi, S ;
Nishi, M .
FUSION ENGINEERING AND DESIGN, 2000, 49-50 :855-861
[2]   GAS-SOLID CHROMATOGRAPHY OF H2, HD, AND D2 - ISOTOPIC SEPARATION AND HEATS OF ADSORPTION ON ALUMINA [J].
MOORE, WR ;
WARD, HR .
JOURNAL OF PHYSICAL CHEMISTRY, 1960, 64 (06) :832-832
[3]   Isotope effect in cryosorption of tritium to molecular sieves and activated carbon at 77 K [J].
Nishikawa, M ;
Tanaka, K ;
Uetake, M ;
Shiraishi, T .
FUSION TECHNOLOGY, 1998, 34 (03) :234-240
[4]   ADSORPTION RATE CONSTANTS FROM CHROMATOGRAPHY [J].
SCHNEIDER, P ;
SMITH, JM .
AICHE JOURNAL, 1968, 14 (05) :762-+
[5]   GAS-CHROMATOGRAPHY FOR MEASUREMENT OF HYDROGEN ISOTOPES AT TRITIUM PROCESSING [J].
UDA, T ;
OKUNO, K ;
SUZUKI, T ;
NARUSE, Y .
JOURNAL OF CHROMATOGRAPHY, 1991, 586 (01) :131-137
[6]   ADSORPTION EQUILIBRIUM OF HYDROGEN ISOTOPES ON ALUMINA ADSORBENTS FOR GAS-SOLID CHROMATOGRAPHY [J].
YAMANISHI, T ;
KUDO, H .
JOURNAL OF CHROMATOGRAPHY, 1989, 475 :125-134