Computer-assisted navigated cup placement of different cup types in hip arthroplasty - A randomised controlled trial

被引:0
|
作者
Bernsmann, K [1 ]
Langlotz, U [1 ]
Ansari, B [1 ]
Wiese, M [1 ]
机构
[1] Giradet Clin Essen, D-45131 Essen, Germany
来源
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE | 2001年 / 139卷 / 06期
关键词
hip arthroplasty; navigation; cup position; CAS;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aim:The position of the acetabular implant has a great influence on the outcome of total hip arthroplasty. The acetabular implants differ in their characteristics during insertion. In order to control the influence of the implant in different axes, 80 implantations of acetabular component were performed under computer-assisted control by a surgigate navigation system. Method: Within a prospektive randomised study, 70 total hip replacements were performed by one surgeon using two different uncemented implants (PPF screw cup/Hedrocel press-fit cup). The position of the cup was measured at different times during surgery and was compared to 10 cemented PE cup placements. Results: During the milling procedure the anteversion of the two uncemented cups differed significantly (p = 0.026). The standard deviation of anteversion during implantation different significantly relating to the cup type: press-fit cup 3.86degrees, screw cup 2.1degrees and cemented PE cups 0,84degrees. The inclination was less susceptible. Conclusion: The cup design of uncemented acetabular implants influences the outcome of surgery. In our trial a spherical press-fit cup showed a greater variability than the screw-cup. The CAS system can be used as a tool to minimise these effects.
引用
收藏
页码:512 / 516
页数:5
相关论文
共 50 条
  • [21] Software-related recalls in computer-assisted hip and knee arthroplasty
    Castagnini, Francesco
    Maestri, Marco
    Tassinari, Enrico
    Masetti, Claudio
    Faldini, Cesare
    Traina, Francesco
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (03) : 641 - 645
  • [23] Software-related recalls in computer-assisted hip and knee arthroplasty
    Francesco Castagnini
    Marco Maestri
    Enrico Tassinari
    Claudio Masetti
    Cesare Faldini
    Francesco Traina
    International Orthopaedics, 2023, 47 : 641 - 645
  • [24] Effectiveness of virtual reality compared to video training on acetabular cup and femoral stem implantation accuracy in total hip arthroplasty among medical students: a randomised controlled trial
    Eustathios Kenanidis
    Panagiotis Boutos
    Grigorios Voulgaris
    Aikaterini Zgouridou
    Eleni Gkoura
    Zakareya Gamie
    George Papagiannakis
    Eleftherios Tsiridis
    International Orthopaedics, 2024, 48 : 625 - 633
  • [25] Effectiveness of virtual reality compared to video training on acetabular cup and femoral stem implantation accuracy in total hip arthroplasty among medical students: a randomised controlled trial
    Kenanidis, Eustathios
    Boutos, Panagiotis
    Voulgaris, Grigorios
    Zgouridou, Aikaterini
    Gkoura, Eleni
    Gamie, Zakareya
    Papagiannakis, George
    Tsiridis, Eleftherios
    INTERNATIONAL ORTHOPAEDICS, 2023, 48 (3) : 625 - 633
  • [26] Functional outcomes following total knee arthroplasty: A randomised trial comparing computer-assisted surgery with conventional techniques
    Blakeney, William G.
    Khan, Riaz J. K.
    Palmer, Jennifer L.
    KNEE, 2014, 21 (02) : 364 - 368
  • [27] Letter to the Editor: Editor's Spotlight/Take 5: No Benefit after THA Performed with Computer-assisted Cup Placement: 10-year Results of a Randomized Controlled Study
    Dorr, Lawrence D.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2017, 475 (02) : 565 - 566
  • [28] Acetabular cup placement and offset control in robotic total hip arthroplasty performed through the modified anterolateral approach
    Avram, George Mihai
    Prill, Robert
    Gurau, Cristian Dorin
    Georgeanu, Vlad
    Deleanu, Bogdan
    Russu, Octav
    Becker, Roland
    Predescu, Vlad
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (09) : 2265 - 2273
  • [29] The learning curve of robotic-arm assisted acetabular cup positioning during total hip arthroplasty
    Kayani, Babar
    Konan, Sujith
    Huq, Sumon S.
    Ibrahim, Mazin S.
    Ayuob, Atif
    Haddad, Fares S.
    HIP INTERNATIONAL, 2021, 31 (03) : 311 - 319
  • [30] Acetabular cup placement and offset control in robotic total hip arthroplasty performed through the modified anterolateral approach
    George Mihai Avram
    Robert Prill
    Cristian Dorin Gurau
    Vlad Georgeanu
    Bogdan Deleanu
    Octav Russu
    Roland Becker
    Vlad Predescu
    International Orthopaedics, 2023, 47 : 2265 - 2273