An Enhanced Experimental Facility for Durability and Performance Characterisation of Piezoelectric Transducers for Structural Health Monitoring

被引:0
|
作者
Jung, George [1 ]
Van der Velden, Steve [1 ]
Tsoi, Kelly [1 ]
Rajic, Nik [1 ]
机构
[1] Def Sci & Technol Org, Fishermans Bend, Vic 3207, Australia
关键词
Piezoceramic transducer; durability; structural health monitoring;
D O I
10.4028/www.scientific.net/KEM.558.374
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
With any structural health monitoring (SHM) system, verification of the health of the sensing elements is essential in ensuring confidence in the measurements furnished by the system. In particular, SHM. systems utilised for structural 'hot spot' monitoring applications will conceivably require transducers to operate reliably after sustained exposure to severe mechanical loading. Consequently, a good understanding of the long term mechanical durability performance of structurally integrated piezoelectric transducers is vital when designing and implementing robust SHM systems. An experimental facility has been developed at the Australian Defence Science and Technology Organisation (DSTO) capable of performing an autonomous long-term mechanical durability test on piezoceramic transducers. The Autonomous Mechanical Durability Experimentation and Analysis System (AMeDEAS) incorporates a general purpose data acquisition program controlling up to three 8-channel relay multiplexers and two instruments. AMeDEAS is highly flexible, allowing user-specified channel configurations and automatic interrogation of selected instruments. The system also interfaces with the uni-axial mechanical testing machine to provide control of the load sequence allowing transducer elements to be interrogated under stable load-free conditions after being subject to a predefined loading regime. AMeDEAS was used to investigate the fatigue characteristics of a low-profile layered piezoceramic transducer package developed by DSTO. A total of 16 transducers were tested under tension-dominated cyclic loading with peak-to-peak strain amplitude increasing from 400 mu epsilon to a maximum of 3000 mu epsilon, with periodic acoustic transduction efficiency and electromechanical impedance measurements taken throughout the test. This paper details the AMeDEAS and includes preliminary results which confirm the efficacy of the new facility.
引用
收藏
页码:374 / 385
页数:12
相关论文
共 50 条
  • [21] Piezoelectric Transducers Assessed by the Pencil Lead Break for Impedance-Based Structural Health Monitoring
    Dare de Almeida, Vinicius Augusto
    Baptista, Fabricio Guimaraes
    de Aguiar, Paulo Roberto
    IEEE SENSORS JOURNAL, 2015, 15 (02) : 693 - 702
  • [22] Shear Mode Ultrasonic Transducers from Flexible Piezoelectric PLLA Fibers for Structural Health Monitoring
    Yousry, Yasmin Mohamed
    Wong, Voon-Kean
    Ji, Rong
    Chen, Yunjie
    Chen, Shuting
    Zhang, Xiuying
    Lim, David Boon Kiang
    Shen, Lei
    Yao, Kui
    ADVANCED FUNCTIONAL MATERIALS, 2023, 33 (15)
  • [23] On the modeling of circular piezoelectric transducers for wave propagation-based structural health monitoring applications
    Lopes, Kayc W.
    Gonsalez-Bueno, Camila G.
    Inman, Daniel J.
    Bueno, Douglas D.
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2023, 34 (15) : 1739 - 1752
  • [24] Evaluation and improvement in sensor performance and durability for structural health monitoring systems
    Blackshire, James L.
    Cooney, Adam
    ADVANCED SENSOR TECHNOLOGIES FOR NONDESTRUCTIVE EVALUATION AND STRUCTURAL HEALTH MONITORING II, 2006, 6179
  • [25] Structural health monitoring of rotary aerospace structures based on electromechanical impedance of integrated piezoelectric transducers
    Hoshyarmanesh, Hamidreza
    Abbasi, Ali
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2018, 29 (09) : 1799 - 1817
  • [26] An experimental investigation on the health monitoring of concrete structures using piezoelectric transducers at various environmental temperatures
    Zou, Dujian
    Liu, Tiejun
    Liang, Chaofeng
    Huang, Yongchao
    Zhang, Fuyao
    Du, Chengcheng
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2015, 26 (08) : 1028 - 1034
  • [27] PVDF-transducers for structural health monitoring
    Hurlebaus, S
    Gaul, L
    RESPONSIVE SYSTEMS FOR ACTIVE VIBRATION CONTROL, 2002, 85 : 285 - 296
  • [28] Multielement Interdigital Transducers for Structural Health Monitoring
    Bulletti, A.
    Giannelli, P.
    Calzolai, M.
    Capineri, L.
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [29] Health monitoring of composite structures using composite piezoelectric transducers
    Blanas, F
    Rigas, E
    Das-Gupta, DK
    STRUCTURAL HEALTH MONTORING 2000, 1999, : 635 - 642
  • [30] Piezoelectric fiber composite transducers for health monitoring in composite structures
    Konka, Hari P.
    Wahab, M. A.
    Lian, K.
    SENSORS AND ACTUATORS A-PHYSICAL, 2013, 194 : 84 - 94