Operator Radiation Exposure in Cone-Beam Computed Tomography Guidance

被引:2
作者
Braak, S. J. [1 ]
Van, M. J. L. Strijen [2 ]
Meijer, E. [2 ]
Van, J. P. M. Heesewijk [2 ]
Mali, W. P. Th M. [3 ]
机构
[1] MRON, Utrecht, Netherlands
[2] St Antonius Hosp, Utrecht, Netherlands
[3] UMCU, Utrecht, Netherlands
关键词
effective dose; staff; needle intervention; cone beam CT; radiation shielding; CT; STAFF; INTERVENTIONS; PATIENT; BIOPSY; RADIOLOGISTS; ACCURACY; SYSTEM;
D O I
10.5334/jbr-btr.816
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Quantitative analysis of operator dose in cone-beam computed tomography guidance (CBCT-guidance) and the effect of protective shielding. Methods: Using a Rando phantom, a model was set-up to measure radiation dose for the operator hand, thyroid and gonad region. The effect of sterile radiation-absorbing drapes and ceiling/couch shielding was measured. Using this model we calculated the dose, based on relevant clinical parameters. The procedures were divided in thoracic and abdominal group. Furthermore, dosimetry measurements were performed during clinical cases to correlate with our calculations. Results: One hundred thirteen procedures were included between December 2007 and January 2010 (47 thoracic, 66 abdominal). The mean hand doses were 34.2 and 54.6 mu Sv (thoracic/abdominal respectively). The thyroid and gonad regions doses were 83.2 and 34.3 mu Sv in the thoracic, and 66.2 and 47.2 mu Sv in the abdominal group. Combined shielding reduced the dose by 98.2-98.9% (p<0.05). The radiation dose in clinical setting in the thoracic group (n=17) was 32.9 mu Sv (hand), 11.4 mu Sv (thyroid) and 16.0 mu Sv (gonad region). In the abdominal group (n=20) the doses were 43.4, 21.7 and 18.8 mu Sv respectively. Conclusion: The operator dose in CBCT-guidance without shielding is quite low, compared to the literature. Based on our data, between 375-830 cases can be performed staying below the yearly limit of 20 mSv effective whole-body dose.
引用
收藏
页数:10
相关论文
共 22 条
[1]   Real-Time 3D Fluoroscopy Guidance During Needle Interventions: Technique, Accuracy, and Feasibility [J].
Braak, S. J. ;
van Strijen, M. J. L. ;
van Leersum, M. ;
van Es, H. W. ;
van Heesewijk, J. P. M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05) :W445-W451
[2]   Effective Dose during Needle Interventions: Cone-beam CT Guidance Compared with Conventional CT Guidance [J].
Braak, Sicco J. ;
van Strijen, Marco J. L. ;
van Es, Hendrik W. ;
Nievelstein, Rutger A. J. ;
van Heesewijk, Johannes P. M. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (04) :455-461
[3]   Evaluation of patient and staff doses during various CT fluoroscopy guided interventions [J].
Buls, N ;
Pagés, J ;
de Mey, J ;
Osteaux, M .
HEALTH PHYSICS, 2003, 85 (02) :165-173
[4]   Improvements in extremity dose assessment for ionising radiation medical applications [J].
Ginjaume, M. ;
Prez, S. ;
Ortega, X. .
RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) :28-32
[5]   Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study [J].
Haeusler, Uwe ;
Czarwinski, Renate ;
Brix, Gunnar .
EUROPEAN RADIOLOGY, 2009, 19 (08) :2000-2008
[6]   Cone-beam CT with flat-panel-detector digital angiography system: Early experience in abdominal interventional procedures [J].
Hirota, Shozo ;
Nakao, Norio ;
Yamamoto, Satoshi ;
Kobayashi, Kaoru ;
Maeda, Hiroaki ;
Ishikura, Reiichi ;
Miura, Koui ;
Sakamoto, Kiyoshi ;
Ueda, Ken ;
Baba, Rika .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 29 (06) :1034-1038
[7]   C-Arm Cone-Beam CT-Guided Percutaneous Transthoracic Lung Biopsy: Usefulness in Evaluation of Small Pulmonary Nodules [J].
Hwang, Hye Sun ;
Chung, Myung Jin ;
Lee, Ju Won ;
Shin, Sung Wook ;
Lee, Kyung Soo .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) :W400-W407
[8]  
ICRP, 2007, ANN ICRP, V103, P1
[9]  
Katada Kazuhiro, 1994, Nippon Acta Radiologica, V54, P1172
[10]   Significant reduction of radiation exposure to operator and staff during cardiac interventions by analysis of radiation leakage and improved lead shielding [J].
Kuon, E ;
Schmitt, M ;
Dahm, JB .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (01) :44-49