Soft Tissue Artifact Assessment During Treadmill Walking in Subjects With Total Knee Arthroplasty

被引:58
作者
Barre, Arnaud [1 ]
Thiran, Jean-Philippe [2 ]
Jolles, Brigitte M. [3 ,4 ]
Theumann, Nicolas [5 ,6 ,7 ]
Aminian, Kamiar [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Lab Movement Anal & Measurement, CH-1051 Lausanne, Switzerland
[2] Ecole Polytech Fed Lausanne, Signal Proc Lab, CH-1051 Lausanne, Switzerland
[3] CHU Vaudois, Dept Orthopaed Surg & Traumatol, CH-1011 Lausanne, Switzerland
[4] Univ Lausanne, CH-1011 Lausanne, Switzerland
[5] CHU Vaudois, Dept Radiol, CH-1011 Lausanne, Switzerland
[6] Univ Lausanne, CH-1011 Lausanne, Switzerland
[7] Clin Bois Cerf, CH-1011 Lausanne, Switzerland
基金
瑞士国家科学基金会;
关键词
Biplane fluoroscopy; human motion analysis; knee kinematics; soft tissue artifact (STA); stereophotogrammetry; JOINT KINEMATICS; SKIN MOVEMENT; MOTION; MODEL; GAIT; STEREOPHOTOGRAMMETRY; FLUOROSCOPY; ACCURACY; MARKERS; QUANTIFICATION;
D O I
10.1109/TBME.2013.2268938
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate measurement of knee kinematics during functional activities suffers mainly from soft tissue artifact (STA): the combination of local surface deformations and rigid movement of markers relative to the underlying bone (also called rigid STA movement: RSTAM). This study proposes to assess RSTAM on the thigh, shank, and knee joint and to observe possible features between subjects. Nineteen subjects with knee arthroplasty were asked to walk on a treadmill while a biplane fluoroscopic system (X-rays) and a stereophotogrammetric system (skin markers) recorded their knee movement. The RSTAM was defined as the rigid movement of the cluster of skin markers relative to the prosthesis. The results showed that RSTAM amplitude represents approximately 80-100% of the STA. The vertical axis of the anatomical frame of the femur was influenced the most by RSTAM. Combined with tibial error, internal/external rotation angle and distraction-compression were the knee kinematics parameters most affected by RSTAM during the gait cycle, with average rms values of 3.8 degrees and 11.1 mm. This study highlighted higher RSTAM during the swing phase particularly in the thigh segment and suggests new features for RSTAM such as the particular shape of some RSTAM waveforms and the absence of RSTAM in certain kinematics during the gait phases. The comparison of coefficient of multiple correlations showed some similarities of RSTAM between subjects, while some correlations were found with gait speed and BMI. These new insights could potentially allow the development of new methods of compensation to avoid STA.
引用
收藏
页码:3131 / 3140
页数:10
相关论文
共 52 条
[1]   Accuracy of single-plane fluoroscopy in determining relative position and orientation of total knee replacement components [J].
Acker, Stacey ;
Li, Rebecca ;
Murray, Heather ;
John, Paul St. ;
Banks, Scott ;
Mu, Shang ;
Wyss, Urs ;
Deluzio, Kevin .
JOURNAL OF BIOMECHANICS, 2011, 44 (04) :784-787
[2]   Non-invasive assessment of soft-tissue artifact and its effect on knee joint kinematics during functional activity [J].
Akbarshahi, Massoud ;
Schache, Anthony G. ;
Fernandez, Justin W. ;
Baker, Richard ;
Banks, Scott ;
Pandy, Marcus G. .
JOURNAL OF BIOMECHANICS, 2010, 43 (07) :1292-1301
[3]   A linear soft tissue artefact model for human movement analysis: Proof of concept using in vivo data [J].
Andersen, Michael S. ;
Damsgaard, Michael ;
Rasmussen, John ;
Ramsey, Dan K. ;
Benoit, Daniel L. .
GAIT & POSTURE, 2012, 35 (04) :606-611
[4]   Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[5]   Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo [J].
Benoit, Daniel L. ;
Ramsey, Dan K. ;
Lamontagne, Mario ;
Xu, Lanyi ;
Wretenberg, Per ;
Renstrom, Per .
GAIT & POSTURE, 2006, 24 (02) :152-164
[6]   Spherical averages and applications to spherical splines and interpolation [J].
Buss, SR ;
Fillmore, JP .
ACM TRANSACTIONS ON GRAPHICS, 2001, 20 (02) :95-126
[7]   A hip joint kinematics driven model for the generation of realistic thigh soft tissue artefacts [J].
Camomilla, Valentina ;
Cereatti, Andrea ;
Cheze, Laurence ;
Cappozzo, Aurelio .
JOURNAL OF BIOMECHANICS, 2013, 46 (03) :625-630
[8]   Soft tissue artifact compensation in knee kinematics by double anatomical landmark calibration: Performance of a novel method during selected motor tasks [J].
Cappello, A ;
Stagni, R ;
Fantozzi, S ;
Leardini, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (06) :992-998
[9]   Surface-marker cluster design criteria for 3-D bone movement reconstruction [J].
Cappozzo, A ;
Cappello, A ;
DellaCroce, U ;
Pensalfini, F .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (12) :1165-1174
[10]   Position and orientation in space of bones during movement: Experimental artefacts [J].
Cappozzo, A ;
Catani, F ;
Leardini, A ;
Benedetti, MG ;
DellaCroce, U .
CLINICAL BIOMECHANICS, 1996, 11 (02) :90-100