Non-contact 3D measuring machine hardware design and precision calibration

被引:0
|
作者
Niu Shuguang [1 ]
Li Degen [2 ]
Chen Xiaoping [2 ]
机构
[1] Changshu Inst Technol, Dept Mech Engn, Changshu 215500, Peoples R China
[2] Heilongjiang Inst Sci & Technol, Coll Mech Engn, Harbin 150027, Peoples R China
来源
2013 FIFTH INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION (ICMTMA 2013) | 2013年
关键词
Optical imaging; Precision calibration; 3D frustum of a cone; Non-contact measurement;
D O I
10.1109/ICMTMA.2013.179
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In order to solve the non-contact three-dimensional coordinate measuring machine accuracy calibration problem, a device used to verify the standard model of non-contact three-dimensional coordinate measuring machine. The technical solution adopted is the isosceles triangle layout of three same height plinth set the composite benchmark testing body, rod and frustum of a cone is measured to object geometric parameters and the corresponding mathematical model of the geometry parameters which will be measured based on the collection and calculation of the spatial coordinates to the verification of the accuracy. The device structure is simple and easy to carry, easy to measure and operation, high accuracy check. Experimental results show that the system can automatically complete the fast measuring machine precision calibration.
引用
收藏
页码:716 / 719
页数:4
相关论文
共 50 条
  • [21] Dynamic and non-contact 3D sample rotation for microscopy
    Frederic Berndt
    Gopi Shah
    Rory M. Power
    Jan Brugués
    Jan Huisken
    Nature Communications, 9
  • [22] A Non-contact Interaction Method for 3D Display Devices
    Wang, Mengkui
    Wang, Wentong
    Xu, Feng
    Liu, Qiang
    WEB AND BIG DATA. APWEB-WAIM 2022 INTERNATIONAL WORKSHOPS, KGMA 2022, SEMIBDMA 2022, DEEPLUDA 2022, 2023, 1784 : 276 - 284
  • [23] Dynamic and non-contact 3D sample rotation for microscopy
    Berndt, Frederic
    Shah, Gopi
    Power, Rory M.
    Brugues, Jan
    Huisken, Jan
    NATURE COMMUNICATIONS, 2018, 9
  • [24] New concept large capacity non-contact measuring machine
    不详
    AIRCRAFT ENGINEERING AND AEROSPACE TECHNOLOGY, 2002, 74 (05): : 477 - 478
  • [25] 3D Thinning Algorithm Based on Topology Preservation and 3D Non-contact Measurement
    Qiao, Mingchuan
    Hong, Hanyu
    Huang, Likun
    Ma, Erwei
    2015 INTERNATIONAL CONFERENCE ON OPTOELECTRONICS AND MICROELECTRONICS (ICOM), 2015, : 277 - 282
  • [26] Design and calibration of the non-contact inductive angular displacement sensor
    Chen X.
    Zhang B.
    Li J.
    Tian Y.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2022, 43 (02): : 36 - 42
  • [27] Precision non-contact measurement of blind holes by machine vision technology
    Fang, ZP
    McClure, VW
    AUTOMATIC INSPECTION AND NOVEL INSTRUMENTATION, 1997, 3185 : 125 - 131
  • [28] Design and Calibration of an Opto-mechanical Appliance for 3D Non-contact Orthopedic Measurements Part I: Mathematical Model and Laboratory Prototype
    Roberto Caracciolo
    Alberto Trevisani
    Journal of Intelligent and Robotic Systems, 2003, 36 : 1 - 21
  • [29] Design and calibration of an opto-mechanical appliance for 3D non-contact orthopedic measurements - Part I: Mathematical model and laboratory prototype
    Caracciolo, R
    Trevisani, A
    JOURNAL OF INTELLIGENT & ROBOTIC SYSTEMS, 2003, 36 (01) : 1 - 21
  • [30] Dynamic characteristics in high precision non-contact machine tool spindles
    Su, JCT
    Huang, BW
    PROGRESS ON ADVANCED MANUFACTURE FOR MICRO/NANO TECHNOLOGY 2005, PT 1 AND 2, 2006, 505-507 : 157 - 162