Particulate matters and gaseous pollutants in indoor environment and Association of ultra-fine particulate matters (PM1) with lung function

被引:27
作者
Akther, Tanzina [1 ]
Ahmed, Morshad [1 ]
Shohel, Mohammad [1 ,2 ]
Ferdousi, Farhana Khanom [1 ]
Salam, Abdus [1 ]
机构
[1] Univ Dhaka, Dept Chem, Dhaka 1000, Bangladesh
[2] Univ Iowa, Dept Chem, Iowa City, IA 52242 USA
关键词
Indoor air quality; Particulate matter; NO2 and TVOC; Hazard ratio indicator; Peak flow rate; Lung function; AIR-POLLUTION; URBAN; CHILDREN; PARTICLES; OUTDOOR; QUALITY; DHAKA; LEAD; SIZE; APPORTIONMENT;
D O I
10.1007/s11356-018-4043-2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Real-time particulate matters (PM1, PM2.5, PM4, PM7, PM10, and TSP) with AEROCET 531S (USA), gaseous pollutants (NO2 and TVOC) with Aeroquel 500 gas sampler (NZ) were measured from the indoor air of houses at four residential locations in Dhaka, Bangladesh. PM10 samples were collected on quartz filters with a dual channel dust sampler (IPM-FDS 2510, India) for selected trace metal determination from five houses of Dhaka. Respiratory function of the occupants was assessed by using a peak expiratory flow meter (Rossmax PF 120). Mean PM1, PM2.5, and PM10 concentrations were 46.1 +/- 13.4, 76.0 +/- 16.2, and 203.9 +/- 44.8gm(-3), respectively. Higher enrichment factors of Pb, Zn, and Ni were found for traffic, industrial, and constructional activities. The correlation between indoor and outdoor PM2.5 (R-2=0.42) and ratios (I/O<1) suggesting indoor air was effected by outdoor air. The concentration of NO2 (0.076 +/- 0.007ppm) and TVOC (90.0 +/- 46.0ppm) was found above than other studies. The average total hazard ratio (THR) in Dhaka was 9.06 and has the highest exposure to air pollutants (PM2.5, PM10, NO2) in Khilkhet (THR 10.1) residents. A negative association between ultra-fine particles (PM1) and peak flow rate measurements of the residents living in these houses indicates that inhalations of ultra-fine particles has great influence on the reduced lung efficiency.
引用
收藏
页码:5475 / 5484
页数:10
相关论文
共 56 条
[1]  
Abrar A., 2014, INT RES J ENV SCI, V3, P38
[2]   Characterization of indoor particle sources: A study conducted in the metropolitan Boston area [J].
Abt, E ;
Suh, HH ;
Allen, G ;
Koutrakis, P .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2000, 108 (01) :35-44
[3]  
Ahmed M, 2018, J ENV POLLUT MANAG, V1, P104
[4]  
[Anonymous], 2018, Household air pollution and health
[5]   Indoor NO2 air pollution and lung function of professional cooks [J].
Arbex, M. A. ;
Martins, L. C. ;
Pereira, L. A. A. ;
Negrini, F. ;
Cardoso, A. A. ;
Melchert, W. R. ;
Arbex, R. F. ;
Saldiva, P. H. N. ;
Zanobetti, A. ;
Braga, A. L. F. .
BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2007, 40 (04) :527-534
[6]  
Begum AB, 2009, J BANGLADESH ACAD SC, V33, P25
[7]   Relationship between outdoor and indoor air quality in eight French schools [J].
Blondeau, P ;
Iordache, V ;
Poupard, O ;
Genin, D ;
Allard, F .
INDOOR AIR, 2005, 15 (01) :2-12
[8]   Thoracic and respirable particle definitions for human health risk assessment [J].
Brown, James S. ;
Gordon, Terry ;
Price, Owen ;
Asgharian, Bahman .
PARTICLE AND FIBRE TOXICOLOGY, 2013, 10
[9]   Effects of particulate air pollution and ozone on lung function in non-asthmatic children [J].
Chen, Chi-Hsien ;
Chan, Chang-Chuan ;
Chen, Bing-Yu ;
Cheng, Tsun-Jen ;
Guo, Yue Leon .
ENVIRONMENTAL RESEARCH, 2015, 137 :40-48
[10]   Review of relationship between indoor and outdoor particles: I/O ratio, infiltration factor and penetration factor [J].
Chen, Chun ;
Zhao, Bin .
ATMOSPHERIC ENVIRONMENT, 2011, 45 (02) :275-288