Ideal entry point for the thoracic pedicle screw during the free hand technique

被引:53
作者
Chung, Kook Jin [2 ]
Suh, Seung Woo [1 ]
Desai, Sameer [1 ]
Song, Hae Ryong [1 ]
机构
[1] Korea Univ, Coll Med, Guro Hosp, Dept Orthopaed, Seoul 136705, South Korea
[2] Hallym Univ, Coll Med, Kangnam Sacred Heart Hosp, Dept Orthopaed, Seoul, South Korea
关键词
D O I
10.1007/s00264-007-0363-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We have attempted to determine the spatial orientation of the base of the superior articular process in relation to the centre of the pedicle and then measure the transverse and sagittal screw angles using this ideal pedicle screw entry point - the base of the superior articular process at the junction of the lateral one-third and medial two-thirds. The proposed advantages of this technique are the easily identifiable entry point, the well-defined transverse and sagittal screw angles and a very low incidence of medial and inferior pedicle violation.
引用
收藏
页码:657 / 662
页数:6
相关论文
共 20 条
[1]   Transpedicular screw placement -: Image-guided versus lateral-view fluoroscopy:: In vitro simulation [J].
Assaker, R ;
Reyns, N ;
Vinchon, M ;
Demondion, X ;
Louis, E .
SPINE, 2001, 26 (19) :2160-2164
[2]  
Berlemann U, 1996, Eur Spine J, V5, P71, DOI 10.1007/BF00307831
[3]   Pedicle instrumentation in the thoracic spine - A morphometric and cadaveric study for placement of screws [J].
Cinotti, G ;
Gumina, S ;
Ripani, M ;
Postacchini, F .
SPINE, 1999, 24 (02) :114-119
[4]  
EBRAHEIM NA, 1997, SPINE, V22, P1160
[5]   Pedicle screw placement in the thoracic spine - A comparison of image-guided and manual techniques in cadavers [J].
Hart, RA ;
Hansen, BL ;
Shea, M ;
Hsu, F ;
Anderson, GJ .
SPINE, 2005, 30 (12) :E326-E331
[6]   Fatal cardiac tamponade associated with posterior spinal instrumentation -: A case report [J].
Heini, P ;
Schöll, E ;
Wyler, D ;
Eggli, S .
SPINE, 1998, 23 (20) :2226-2230
[7]   Computer-assisted thoracic pedicle screw placement -: An in vitro feasibility study [J].
Kim, KD ;
Johnson, JP ;
Bloch, O ;
Masciopinto, JE .
SPINE, 2001, 26 (04) :360-364
[8]   Free hand pedicle screw placement in the thoracic spine: Is it safe? [J].
Kim, YJ ;
Lenke, LG ;
Bridwell, KH ;
Cho, YSS ;
Riew, KD .
SPINE, 2004, 29 (03) :333-342
[9]  
KIM YJ, 2004, INT M ADV SPIN TECHN
[10]   MORPHOMETRY OF THE THORACIC AND LUMBAR SPINE RELATED TO TRANSPEDICULAR SCREW PLACEMENT FOR SURGICAL SPINAL FIXATION [J].
KRAG, MH ;
WEAVER, DL ;
BEYNNON, BD ;
HAUGH, LD .
SPINE, 1988, 13 (01) :27-32