Expanding the Cone Location and Magnitude Index to Include Corneal Thickness and Posterior Surface Information for the Detection of Keratoconus

被引:63
作者
Mahmoud, Ashraf M. [1 ,2 ]
Nunez, Maria X. [3 ]
Blanco, Claudia [3 ]
Koch, Douglas D. [4 ]
Wang, Li [4 ]
Weikert, Mitchell P. [4 ]
Frueh, Beatrice E. [5 ]
Tappeiner, Christoph [5 ]
Twa, Michael D. [6 ]
Roberts, Cynthia J. [1 ,2 ]
机构
[1] Ohio State Univ, Dept Ophthalmol, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
[3] Pontificia Univ Javeriana, Clin Oftalmol Cali, Cali, Colombia
[4] Baylor Coll Med, Cullen Eye Inst, Dept Ophthalmol, Houston, TX 77030 USA
[5] Univ Hosp Bern, Dept Ophthalmol, Inpelspital, CH-3010 Bern, Switzerland
[6] Univ Houston, Coll Optometry, Houston, TX USA
关键词
D O I
10.1016/j.ajo.2013.07.018
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To extend the capabilities of the Cone Location and Magnitude Index algorithm to include a combination of topographic information from the anterior and posterior corneal surfaces and corneal thickness measurements to further improve our ability to correctly identify keratoconus using this new index: ConeLocationMagnitudeIndex_X. DESIGN: Retrospective case-control study. METHODS: Three independent data sets were analyzed: 1 development and 2 validation. The Anterior Corneal-Power index was calculated to stratify the keratoconus data from mild to severe. The ConeLocationMagnitudeIndex algorithm was applied to all tomography data collected using a dual Scheimpflug-Placido-based tomographer. The ConeLocationMagnitudeIndex_X formula, resulting from analysis of the Development set, was used to determine the logistic regression model that best separates keratoconus from normal and was applied to all data sets to calculate PercentProbabilityKeratoconus_X. The sensitivity/specificity of PercentProbabilityKeratoconus_X was compared with the original PercentProbabilityKeratoconus, which only uses anterior axial data. " RESULTS: The AnteriorCornealPower severity distribution for the combined data sets are 136 mild, 12 moderate, and 7 severe. The logistic regression model generated for ConeLocationMagnitudeIndex_X produces complete separation for the Development set. Validation Set 1 has 1 false-negative and Validation Set 2 has 1 false-positive. The overall sensitivity/specificity results for the logistic model produced using the ConeLocationMagnitudeIndex_X algorithm are 99.4% and 99.6%, respectively. The overall sensitivity/specificity results for using the original ConeLocationMagnitudeIndex algorithm are 89.2% and 98.8%, respectively. CONCLUSIONS: ConeLocationMagnitudeIndex X provides a robust index that can detect the presence or absence of a keratoconic pattern in corneal tomography maps with improved sensitivity/specificity from the original anterior surface only ConeLocationMagnitudeIndex algorithm. ((C) 2013 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:1102 / 1111
页数:10
相关论文
共 12 条
[1]  
Ambrosio R, 2003, J REFRACT SURG, V19, P24
[2]   Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconus [J].
Ambrosio, Renato, Jr. ;
Alonso, Ruiz Simonato ;
Luz, Allan ;
Coca Velarde, Luis Guillermo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) :1851-1859
[3]  
Argawal V, 2013, IJKECD, V2, P16
[4]   CLMI - The Cone Location and Magnitude Index [J].
Mahmoud, Ashraf M. ;
Roberts, Cynthia J. ;
Lembach, Richard G. ;
Twa, Michael D. ;
Herderick, Edward E. ;
McMahon, Timothy T. .
CORNEA, 2008, 27 (04) :480-487
[5]   Simulation of machine-specific topographic indices for use across platforms [J].
Mahmoud, Ashraf M. ;
Roberts, Cynthia ;
Lembach, Richard ;
Herderick, Edward E. ;
Mcmahon, Timothy T. .
OPTOMETRY AND VISION SCIENCE, 2006, 83 (09) :682-693
[6]  
MANDELL RB, 1969, ARCH OPHTHALMOL-CHIC, V82, P182
[7]   A new method for grading the severity of keratoconus - The Keratoconus Severity Score (KSS) [J].
McMahon, Timothy T. ;
Szczotka-Flynn, Loretta ;
Barr, Joseph T. ;
Anderson, Robert J. ;
Slaughter, Mary E. ;
Lass, Jonathan H. ;
Iyengar, Sudha K. .
CORNEA, 2006, 25 (07) :794-800
[8]   Corneal imaging with slit-scanning and Scheimpflug imaging techniques [J].
Oliveira, Cristina M. ;
Ribeiro, Celina ;
Franco, Sandra .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2011, 94 (01) :33-42
[9]   Topographic and biomechanical differences between hyperopic and myopic laser in situ keratomileusis [J].
Qazi, MA ;
Roberts, CJ ;
Mahmoud, AM ;
Pepose, JS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :48-60
[10]   Novel Objective Method for Comparing Ablation Centration With and Without Pupil Tracking Following Myopic Laser In Situ Keratomileusis Using the Bausch & Lomb Technolas 217A [J].
Qazi, Mujtaba A. ;
Pepose, Jay S. ;
Sanderson, Jeff P. ;
Mahmoud, Ashraf M. ;
Roberts, Cynthia J. .
CORNEA, 2009, 28 (06) :616-625