Repair of distal biceps tendon rupture with the Biotenodesis screw

被引:44
作者
Khan, W [1 ]
Agarwal, M [1 ]
Funk, L [1 ]
机构
[1] Hope Hosp, Dept Orthopaed & Trauma, Salford M6 8HD, Lancs, England
关键词
distal biceps tendon rupture; bioabsorbable; interference screw; minimal incision;
D O I
10.1007/s00402-004-0639-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background. Distal biceps tendon ruptures are uncommon injuries with only around 300 cases reported in the literature. Current management tends to favour anatomical reinsertion of the tendon into the radial tuberosity, especially in young and active individuals. These injuries are commonly repaired using either a single anterior incision with suture anchors or the Boyd-Anderson dual incision technique. Case report. We report the use of a bioabsorbable interference screw for the repair of distal biceps tendon rupture using a minimal incision technique. In this technique the avulsed tendon and a bioabsorbable screw are secured in a drill hole on the radial tuberosity using whip stitch and fibre wire sutures according to Biotenodesis system guidelines. Conclusion. The technique described requires minimal volar dissection that is associated with a reduced number of synostosis and posterior interosseous nerve injuries. The bioabsorbable interference screw has all the advantages of being biodegradable and has been shown to have greater pullout strength than suture anchors. It is also a reasonable alternative to titanium screws in terms of primary fixation strength. The strong fixation provided allows early active motion and return to previous activities as seen in our case.
引用
收藏
页码:206 / 208
页数:3
相关论文
共 25 条
[1]  
Aldridge JW, 2000, HAND CLIN, V16, P497
[2]   THE IN-VIVO HISTOLOGY OF AN ABSORBABLE SUTURE ANCHOR - A PRELIMINARY-REPORT [J].
BARBER, FA ;
DECK, MA .
ARTHROSCOPY, 1995, 11 (01) :77-81
[3]   Distal biceps brachii tendon repair - An in vitro biomechanical study of tendon reattachment [J].
Berlet, GC ;
Johnson, JA ;
Milne, AD ;
Patterson, SD ;
King, GJW .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1998, 26 (03) :428-432
[4]  
Bernstein A D, 2001, Am J Orthop (Belle Mead NJ), V30, P193
[5]   Arthroscopic biceps tenodesis: A new technique using bioabsorbable interference screw fixation [J].
Boileau, P ;
Krishnan, SG ;
Coste, JS ;
Walch, G .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (09) :1002-1012
[6]   A METHOD FOR REINSERTION OF THE DISTAL BICEPS BRACHII TENDON [J].
BOYD, HB ;
ANDERSON, LD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1961, 43 (07) :1041-1043
[7]   Clinical, functional, and radiographic assessments of the conventional and modified Boyd-Anderson surgical procedures for repair of distal biceps tendon ruptures [J].
D'Arco, P ;
Sitler, M ;
Kelly, J ;
Moyer, R ;
Marchetto, P ;
Kimura, I ;
Ryan, J .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1998, 26 (02) :254-261
[8]   Serial magnetic resonance imaging evaluation of operative site after fixation of patellar tendon graft with bioabsorbable interference screws in anterior cruciate ligament reconstruction [J].
Lajtai, G ;
Noszian, I ;
Humer, K ;
Unger, F ;
Aitzetmüller, G ;
Orthner, E .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1999, 15 (07) :709-718
[9]  
Lintner S, 1996, CLIN ORTHOP RELAT R, P116
[10]  
MCREYNOLDS IS, 1963, J BONE JOINT SURG AM, V45, P1780