Exergy analysis of single-stage and multi stage thermoelectric cooler

被引:46
作者
Sharma, Sudhanshu
Dwivedi, V. K.
Pandit, S. N.
机构
[1] Mechanical Engineering, Mewar University, Rajasthan
关键词
Thermoelectric cooler; Exergy; Single stage; Multi stage; Second law efficiency; COP; PERFORMANCE; DEVICES; GENERATION; DESIGN;
D O I
10.1002/er.3043
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Thermoelectric devices are solid-state devices. Semiconductor thermoelectric cooling, based on the Peltier effect, has interesting capabilities compared to conventional cooling systems. In this work second law analysis of thermoelectric coolers has been done with the help of exergy destruction. In the first part, performance of single-stage thermoelectric coolers and multi stage thermoelectric coolers has been compared for same number of thermoelectric elements i.e. 50. The performance parameters considered to compare their performance are rate of refrigeration, coefficient of performance, second law efficiency and exergy destruction. In second part, multi stage thermoelectric coolers have been analyzed for three different combinations of number of elements in two stages of thermoelectric coolers. The result of the analysis shows that the performance of a multi stage thermoelectric cooler which has total 50 elements gives best performance when it has 30 elements in hotter side and 20 elements in colder side out of the three cases considered. The comparison of single-stage thermoelectric cooler and multistage thermoelectric cooler shows that for same number of elements rate of refrigeration (ROR) of single-stage thermoelectric cooler is much higher than that of multi stage thermoelectric cooler. The COP remains same for both of them but the peak value of cop is obtained at much lower value of current supplied in multi stage thermoelectric cooler. Exergy destruction has constant values in single stage as well as multi stage thermoelectric cooler when the two stages have equal number of elements but it decreases with increase in x. The result of comparison of multistage thermoelectric cooler for three values of x i.e. 0.5, 1, 1.5 shows that the COP, ROR and second law efficiency improve and exergy destruction degrades with increase in x and the best performance has been obtained for x=1.5 out of the three values considered. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:213 / 222
页数:10
相关论文
共 20 条
  • [1] Bansal PK, 2000, INT J ENERG RES, V24, P93, DOI 10.1002/(SICI)1099-114X(200002)24:2<93::AID-ER563>3.0.CO
  • [2] 2-6
  • [3] Multi-objective genetic algorithm optimization of thermoelectric heat exchanger for waste heat recovery
    Belanger, Simon
    Gosselin, Louis
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2012, 36 (05) : 632 - 642
  • [4] Thermoelectric air-cooling module for electronic devices
    Chang, Yu-Wei
    Chang, Chih-Chung
    Ke, Ming-Tsun
    Chen, Sih-Li
    [J]. APPLIED THERMAL ENGINEERING, 2009, 29 (13) : 2731 - 2737
  • [5] Thermoelectric cooler application in electronic cooling
    Chein, R
    Huang, GM
    [J]. APPLIED THERMAL ENGINEERING, 2004, 24 (14-15) : 2207 - 2217
  • [6] Development of an energy-saving module via combination of solar cells and thermoelectric coolers for green building applications
    Cheng, Tsung-Chieh
    Cheng, Chin-Hsiang
    Huang, Zhu-Zin
    Liao, Guo-Chun
    [J]. ENERGY, 2011, 36 (01) : 133 - 140
  • [7] Experimental investigation on a thermoelectric refrigerator driven by solar cells
    Dai, YJ
    Wang, RZ
    Ni, L
    [J]. RENEWABLE ENERGY, 2003, 28 (06) : 949 - 959
  • [8] Thermoelectric cooling and power generation
    DiSalvo, FJ
    [J]. SCIENCE, 1999, 285 (5428) : 703 - 706
  • [9] Design and testing of a microprocessor-controlled portable thermoelectric medical cooling kit
    Güler, NF
    Ahiska, R
    [J]. APPLIED THERMAL ENGINEERING, 2002, 22 (11) : 1271 - 1276
  • [10] Experimental and theoretical study of an integrated thermoelectric-photovoltaic system for air dehumidification and fresh water production
    Jradi, M.
    Ghaddar, N.
    Ghali, K.
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2012, 36 (09) : 963 - 974