The Lightning Contingency Probability Analysis on Transmission Tower with Line Arresters Protection

被引:0
|
作者
Kuo, Cheng-Chien [1 ]
Chang, Hong-Chan [2 ]
Chen, Fu-Hsien [1 ]
机构
[1] St Johns Univ, Dept Elect Engn, New Taipei, Taiwan
[2] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, Taipei, Taiwan
关键词
Lightning; Line arrester; Electro-Magnetic Transient Program; Transmission system; Failure probability; MODEL;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The contingency probability analysis on transmission tower under lightning stroke with various configurations of line arresters is proposed in this paper. The simulation and calculated approach is developed to evaluate the performance for different line arrester installed scheme and capacity. The Electro-Magnetic Transients Program (EMTP) is used to simulate the effect of system under lightning strike on transmission system. The considered components of the study system including lightning surge, line arrester, transmission line and tower. All of the components are modeled to fit the situation of Taiwan under EMTP for more realistic purpose. Then, the proposed simulation procedure is applied to calculate the failure probability of the line arrester by considering the random properties of lighting current, including the wave-tail and peak value of the lightning surge. The comparative studies, which considering the thermal capacity, number of installed arresters, installation position of the arresters, and the footing resistance of transmission tower, are conducted to provide appropriate suggestion for installation strategies of the line arrester. Results obtained from this study can provide the electric utility with valuable quantitative information due to the cost-benefit analysis for the installing of line arrester.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] New tower model in calculation of lightning protection on transmission line
    Zhang, Ying
    Gao, Yadong
    Du, Bin
    Shi, Wei
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2004, 38 (04): : 365 - 368
  • [2] Lightning Performance Analysis of an Overhead Transmission Line Protected by Surge Arresters
    Velasco, J. A. M.
    Aranda, F. C.
    IEEE LATIN AMERICA TRANSACTIONS, 2009, 7 (01) : 62 - 70
  • [3] Design and application of line surge arresters to improve lightning protection characteristics of transmission lines
    He, Jin-Liang
    Zeng, Rong
    Hu, Jun
    Chen, Shui-Ming
    Zhao, Jie
    2008 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2008, : 1562 - +
  • [4] Simulation of Line Surge Arresters for Lightning Protection in 10kV Transmission Lines
    Wang Yong
    Xie Pu
    Zhao Jin-cheng
    Zhang Gui-fang
    2008 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION, VOLS 1 AND 2, 2009, : 269 - +
  • [5] Evaluation of transmission line arresters against winter lightning
    Wakai, T
    Itamoto, N
    Sakai, T
    Ishii, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (02) : 684 - 690
  • [6] Analysis on lightning protection effect of line surge arresters on a compact designed 500 kV Chang-Fang transmission line
    He, Jinliang
    Gao, Yuming
    Chen, Shuiming
    Wu, Weihan
    2000, Sci Publ House (33):
  • [7] Analysis on lightning protection effect of line surge arresters on a compact designed 500 kV Chang-Fang transmission line
    He, Jinliang
    Gao, Yuming
    Chen, Shuiming
    Wu, Weihan
    Zhongguo Dianli/Electric Power, 2000, 33 (04): : 42 - 44
  • [9] Lightning Outage Transmission Line Reliability Improvement with Surge Arresters
    Romualdo-Torres, C.
    Ramirez-Gonzalez, M.
    Escamilla-Paz, A.
    2016 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2016,
  • [10] Lightning protection of the overhead transmission lines long spans without ground wires by using line arresters
    Savic, Milan
    Banjanin, Mladen
    2024 23RD INTERNATIONAL SYMPOSIUM INFOTEH-JAHORINA, INFOTEH, 2024,