Low-Sample Flow Secondary Electrospray Ionization: Improving Vapor Ionization Efficiency

被引:32
作者
Vidal-de-Miguel, G. [1 ]
Macia, M. [1 ]
Pinacho, P. [1 ]
Blanco, J. [1 ]
机构
[1] Univ Valladolid, Energy & Fluid Mech Engn Dept, E-47002 Valladolid, Spain
关键词
ION MOBILITY SPECTROMETRY; MASS-SPECTROMETRY; GAS-CHROMATOGRAPHY; PHASE; EVAPORATION; VOLATILES;
D O I
10.1021/ac3005378
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In secondary electrospray ionization (SESI) systems, gaseous analytes exposed to an elecrospray plume become ionized after charge is transferred from the charging electrosprayed particles to the sample species. Current SESI systems have shown a certain potential. However, their ionization efficiency is limited by space charge repulsion and by the high sample flows required to prevent vapor dilution. As a result, they have a poor conversion ratio of vapor into ions. We have developed and tested a new SESI configuration, termed low-flow SESI, that permits the reduction of the required sample flows. Although the ion to vapor concentration ratio is limited, the ionic flow to sample vapor flow ratio theoretically is not. The new ionizer is coupled to a planar differential mobility analyzer (DMA) and requires only 0.2 Ipm of vapor sample flow to produce 3.5 Ipm of ionic flow. The achieved ionization efficiency is 1/700 (one ion for every 700 molecules) for TNT and, thus, compared with previous SESI ionizers coupled with atmospheric pressure ionization-mass spectrometry (API-MS) (Mesonero, E.; Sillero, J. A.; Hernandez, M.; Fernandez de la Mora, J. Philadelphia PA, 2009) has been improved by a large factor of at least 50-100 (our measurements indicate 70). The new ionizer coupled with the planar DMA and a triple quadrupole mass spectrometer (ABSciex API5000) requires only 20 fg (50 million molecules) to produce a discernible signal after mobility and MS2 analysis.
引用
收藏
页码:8475 / 8479
页数:5
相关论文
共 40 条
[11]   Ion Mobility Measurements of Nondenatured 12-150 kDa Proteins and Protein Multimers by Tandem Differential Mobility Analysis-Mass Spectrometry (DMA-MS) [J].
Hogan, Christopher J., Jr. ;
Fernandez de la Mora, Juan .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2011, 22 (01) :158-172
[12]   Ion-Pair Evaporation from Ionic Liquid Clusters [J].
Hogan, Christopher J., Jr. ;
Fernandez de la Mora, Juan .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2010, 21 (08) :1382-1386
[13]   Tandem ion mobility-mass spectrometry (IMS-MS) study of ion evaporation from ionic liquid-acetonitrile nanodrops [J].
Hogan, Christopher J., Jr. ;
de la Mora, Juan Fernandez .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2009, 11 (36) :8079-8090
[14]   ATMOSPHERIC-PRESSURE ION EVAPORATION MASS-SPECTROMETRY [J].
IRIBARNE, JV ;
DZIEDZIC, PJ ;
THOMSON, BA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 50 (03) :331-347
[15]   ELECTROSPRAY: FROM IONS IN SOLUTION TO IONS IN THE GAS PHASE, WHAT WE KNOW NOW [J].
Kebarle, Paul ;
Verkerk, Udo H. .
MASS SPECTROMETRY REVIEWS, 2009, 28 (06) :898-917
[16]  
Labowsky M., 1985, US Patent, Patent No. [4,531,056, 4531056]
[17]   The Gas Phase Structure of Coulombically Stretched Polyethylene Glycol Ions [J].
Larriba, Carlos ;
de la Mora, Juan Fernandez .
JOURNAL OF PHYSICAL CHEMISTRY B, 2012, 116 (01) :593-598
[18]   The Mobility-Volume Relationship below 3.0 nm Examined by Tandem Mobility-Mass Measurement [J].
Larriba, Carlos ;
Hogan, Christopher J., Jr. ;
Attoui, Michel ;
Borrajo, Rafael ;
Garcia, Juan Fernandez ;
de la Mora, Juan Fernandez .
AEROSOL SCIENCE AND TECHNOLOGY, 2011, 45 (04) :453-467
[19]   On the Mechanism of Extractive Electrospray Ionization [J].
Law, Wai Siang ;
Wang, Rui ;
Hu, Bin ;
Berchtold, Christian ;
Meier, Lukas ;
Chen, Huanwen ;
Zenobi, Renato .
ANALYTICAL CHEMISTRY, 2010, 82 (11) :4494-4500
[20]   Gas chromatography connected to multiple channel electrospray ionization mass spectrometry for the detection of volatile organic compounds [J].
Lee, CY ;
Shiea, J .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2757-2761