Investigating the use of non-attenuation corrected PET images for the attenuation correction of PET data in PET/MR systems

被引:0
|
作者
Chang, Tingting [1 ]
Clark, John W., Jr. [1 ]
Mawlawi, Osama R. [2 ]
机构
[1] Rice Univ, Dept Elect & Comp Engn, Houston, TX 77005 USA
[2] Dept Imaging Phys, Houston, TX 77030 USA
来源
2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2011年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
MR-based attenuation correction (AC) in PET/MR imaging is currently evaluated by many groups. The aim of this study is to investigate the feasibility of using the non-attenuated PET images (PET-NAC) as a means for the AC of PET images in PET/MR systems. A water fillable torso phantom with hollow spheres was scanned on a GE Discovery-RX PET/CT scanner. The activity concentration in the spheres and background was 37.2 and 6.27 kBq/cc respectively. A PET scan was acquired in 3D using 2 FOV with 5min / FOV. CT-AC PET (PET-CTAC), PET-NAC, and CT images were generated. In addition the PET-NAC images were used to create an attenuation map through an iterative segmentation process in three steps. In the first step of the process, the phantom body contour was segmented from the PET-NAC image. Voxels inside the contour were then assigned a value of 0.094 cm(-1) to represent the attenuation coefficient of soft tissue at 511 keV. This segmented attenuation map was then used to attenuate correct the raw PET data and the resulting PET images were used as the input to the second step of the process. The lung region was segmented in the second step and voxels were assigned a value of 0.024 cm(-1) representing the attenuation coefficients of lung tissue at 511 keV. The updated attenuation map was then used for a second time to attenuate correct the raw PET data, and the resulting PET images were used as the input to the third step. The purpose of the third step is to delineate parts of the heart and liver from the lung contour since these parts were unavoidably included in the lung contour of the second step. These parts were then corrected by using a value of 0.094 cm(-1) in the attenuation map. Finally the attenuation coefficients of the scanner couch were included based on the CT images to eliminate the impact of the couch on the accuracy of AC. This final attenuation map was then used to attenuate correct the raw PET data and resulted in a final PET image (PET-IAC). Visual inspection and SUV measurements of the spheres between PET-IAC and the PET-CTAC were performed to assess the accuracy of image quantification. Furthermore, our proposed approach was used on two patients with lung and liver tumors to assess its feasibility in clinical studies. The results show that there is very small difference between the PET-IAC and PET-CTAC from visual inspection. PET-IAC SUVs are on average equal to 94 +/- 3% compared to the SUVs from the PET-CTAC in phantom study. For the two patient studies, this value is 111 +/- 12%. In conclusion, the use of PET-NAC as a means for the AC of PET images is feasible in the clinic. Such approach can potentially be an alternative method of MR-based AC in PET/MR imaging.
引用
收藏
页码:3784 / 3787
页数:4
相关论文
共 50 条
  • [21] Attenuation correction of the PET ACR phantom using templates in PET/MR systems
    Meier, Joseph
    Mawlawi, Osama
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [22] Attenuation Correction of PET/MR Imaging
    Chen, Yasheng
    An, Hongyu
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2017, 25 (02) : 245 - +
  • [23] Truncation Completion of MR-based PET Attenuation Maps Using Time-of-flight Non-attenuation-corrected PET Images
    Qian, Rua
    Manjeshwar, Ravi M.
    Ambwani, Sonal
    Wollenweber, Scott D.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2773 - 2775
  • [24] MR-Based PET Attenuation Correction for PET/MR Imaging
    Bezrukov, Ilja
    Mantlik, Frederic
    Schmidt, Holger
    Schoelkopf, Bernhard
    Pichler, Bernd J.
    SEMINARS IN NUCLEAR MEDICINE, 2013, 43 (01) : 45 - 59
  • [25] A review of PET attenuation correction methods for PET-MR
    Georgios Krokos
    Jane MacKewn
    Joel Dunn
    Paul Marsden
    EJNMMI Physics, 10
  • [26] Evaluation of attenuation correction in cardiac PET using PET/MR
    Jeffrey M. C. Lau
    R. Laforest
    H. Sotoudeh
    X. Nie
    S. Sharma
    J. McConathy
    E. Novak
    A. Priatna
    R. J. Gropler
    P. K. Woodard
    Journal of Nuclear Cardiology, 2017, 24 : 839 - 846
  • [27] A review of PET attenuation correction methods for PET-MR
    Krokos, Georgios
    Mackewn, Jane
    Dunn, Joel
    Marsden, Paul
    EJNMMI PHYSICS, 2023, 10 (01)
  • [28] Evaluation of attenuation correction in cardiac PET using PET/MR
    Lau, Jeffrey M. C.
    Laforest, R.
    Sotoudeh, H.
    Nie, X.
    Sharma, S.
    McConathy, J.
    Novak, E.
    Priatna, A.
    Gropler, R. J.
    Woodard, P. K.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (03) : 839 - 846
  • [29] A hybrid method for generation of attenuation map for MR-based attenuation correction of PET data in prostate PET/MR imaging
    Mehdi Shirin Shandiz
    Mohammad Hadi Arabi
    Pardis Ghafarian
    Mehrdad Bakhshayesh Karam
    Hamidreza Saligheh Rad
    Mohammad Reza Ay
    EJNMMI Physics, 1 (Suppl 1)
  • [30] Template based Attenuation Correction for PET in MR-PET Scanners
    Kops, Elena Rota
    Herzog, Hans
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3061 - 3064