Graphite Supported Preparation (GSP) of α-Cyano-4-Hydroxycinnamic Acid (CHCA) for Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry (MALDI-MS) for Peptides and Proteins

被引:22
作者
Gorka, Jan [1 ]
Bahr, Ute [1 ]
Karas, Michael [1 ]
机构
[1] Goethe Univ Frankfurt, Inst Pharmaceut Chem, Frankfurt, Germany
关键词
MALDI-MS; Sample preparation; Graphite supported crystallization; alpha-Cyano-4-hydroxycinnamic acid (CHCA); SAMPLE PREPARATION; PLATE; IONIZATION; DESORPTION; PENCIL;
D O I
10.1007/s13361-012-0478-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Graphite as MALDI matrix or in combination with other substances has been reported in recent years. Here, we demonstrate that graphite can be used as target coating supporting the crystallization of the alpha-cyano-4-hydroxycinnamic acid matrix. A conventional dried-droplet preparation of matrix and analyte solution on a graphite-coated metal target leads to a thin, uniform layer of cubic crystals with about 1 mu m edge length. Commercially available graphite powder of 1-2 mu m particle size is gently wiped over the target using a cotton Q-tip, leading to an ultra-thin, not-visible film. This surface modification considerably improves analysis of peptides and proteins for MALDI MS using conventional dried-droplet preparation. Compared with untreated targets, the signal intensities of standard peptides are up to eight times higher when using the graphite supported crystallization. The relative standard deviation in peak area of angiotensin II for sample amounts between 1 and 50 fmol is reduced to about 15 % compared with 45 % for untreated sample holders. For a quantification of 1 fmol of the peptide using an internal standard the coefficient of variation is reduced to 3.5 % from 8 %. The new graphite supported preparation (GSP) protocol is very simple and does not require any technical nor manual skills. All standard solvents for peptides and proteins can be used.
引用
收藏
页码:1949 / 1954
页数:6
相关论文
共 22 条
[1]  
Bahr U, 1997, J MASS SPECTROM, V32, P1111, DOI 10.1002/(SICI)1096-9888(199711)32:10<1111::AID-JMS567>3.0.CO
[2]  
2-Y
[3]  
Beavis R C, 1989, Rapid Commun Mass Spectrom, V3, P432, DOI 10.1002/rcm.1290031207
[4]   The use of pencil lead as a matrix and calibrant for matrix-assisted laser desorption/ionisation [J].
Black, C ;
Poile, C ;
Langley, J ;
Herniman, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (07) :1053-1060
[5]  
Cha S, 2003, B KOR CHEM SOC, V24, P1308
[6]   Two-layer sample preparation: A method for MALDI-MS analysis of complex peptide and protein mixtures [J].
Dai, YQ ;
Whittal, RM ;
Li, L .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :1087-1091
[7]   Graphite/liquid mixed matrices for laser desorption/ionization mass spectrometry [J].
Dale, MJ ;
Knochenmuss, R ;
Zenobi, R .
ANALYTICAL CHEMISTRY, 1996, 68 (19) :3321-3329
[8]  
Fenyo David, 2007, J Vis Exp, P192, DOI 10.3791/192
[9]   Mass spectrometry of full-length integral membrane proteins to define functionally relevant structural features [J].
Gabant, Guillaume ;
Cadene, Martine .
METHODS, 2008, 46 (02) :54-61
[10]   4-Chloro-α-cyanocinnamic acid is an advanced, rationally designed MALDI matrix [J].
Jaskolla, Thorsten W. ;
Lehmann, Wolf-Dieter ;
Karas, Michael .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2008, 105 (34) :12200-12205