Background The aim of this study was to evaluate the diagnostic relevance of 3-dimensional (3D) echocardiography in the assessment of secundum atrial septum defect (ASD2). Methods and Results Twenty-three patients (age 2 to 58 years) with an ASD2 were studied by transthoracic (n = 9) or transesophageal (n = 14) echocardiography for the acquisition of a 3D data set before undergoing surgical repair. Qualitative (location, shape, and structure) and quantitative (largest and smallest anteroposterior and superoinferior diameters) characteristics were analyzed and compared with surgical findings. Intraobserver and interobserver variability were assessed. The gross anatomy of the ASD2, shown by the 3D images, was confirmed by the surgeon in 21 of 23 patients, but the presence of membranous or fenestrated remnants of the valvula foramina ovalis in the defect was not optimally visualized in 7 patients. Three-dimensional echocardiography revealed changes in diameter and shape of the ASD2 during the cardiac cycle. The measured largest and smallest anteroposterior diameters and their intraobserver and interobserver agreement were 274 +/- 12 mm, r = 0.95 (P <.001), r = 0.92 (P <.001), and 194 +/- 9 mm, r = 0.96 (P <.001), r = 0.94 (P <.001), respectively. The measured largest and smallest superoinferior diameter and their intraobserver and interobserver agreement were 304 +/- 26 mm, r = 0.90 (P <.001), r = 0.97 (P <.001), and 204 +/- 10 mm, r = 0.83 (P <.001), r = 0.84 (P <.001), respectively. The correlation coefficient between 2D and 3D echocardiography for the largest anteroposterior and superoinferior diameter was r = 0.69 (P <.001) and r = 0.68 (P =.05), respectively. The correlation coefficient between the measurements from 3D reconstructions and direct surgical measurements was r = 0.20 (P = not significant) and r = 0.57 (P <.05), whereas between 2D and surgery was r = 0.50 (P <.05) and r = 0.26 (P = not significant). Conclusions ASD2 has a complex morphology. Three-dimensional echocardiography provides better qualitative and quantitative information on its dynamic geometry, location, and extension as compared with standard 2D echocardiography and might be useful for device selection during catheter-based closure of ASD2.
引用
收藏
页码:1075 / 1081
页数:7
相关论文
共 23 条
  • [11] LUDOMIRSKY A, 1994, TRANSESOPHAGEAL ECHO, P200
  • [12] Volume-rendered, three-dimensional echocardiographic determination of the size, shape, and position of atrial septal defects: Validation in an in vitro model
    Magni, G
    Cao, QL
    Sugeng, L
    Delabays, A
    Marx, G
    Ludomirski, A
    Vogel, M
    Pandian, NG
    [J]. AMERICAN HEART JOURNAL, 1996, 132 (02) : 376 - 381
  • [13] DELINEATION OF SITE, RELATIVE SIZE AND DYNAMIC GEOMETRY OF ATRIAL SEPTAL-DEFECTS BY REAL-TIME 3-DIMENSIONAL ECHOCARDIOGRAPHY
    MARX, GR
    FULTON, DR
    PANDIAN, NG
    VOGEL, M
    CAO, QL
    LUDOMIRSKY, A
    DELABAYS, A
    SUGENG, L
    KLAS, B
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (02) : 482 - 490
  • [14] TRANSESOPHAGEAL DOPPLER COLOR FLOW MAPPING ASSESSMENT OF ATRIAL SEPTAL-DEFECT
    MEHTA, RH
    HELMCKE, F
    NANDA, NC
    HSIUNG, M
    PACIFICO, AD
    HSU, TL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (04) : 1010 - 1016
  • [15] USES AND LIMITATIONS OF TRANSTHORACIC ECHOCARDIOGRAPHY IN THE ASSESSMENT OF ATRIAL SEPTAL-DEFECT IN THE ADULT
    MEHTA, RH
    HELMCKE, F
    NANDA, NC
    PINHEIRO, L
    SAMDARSHI, TE
    SHAH, VK
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (04) : 288 - 294
  • [16] DIAGNOSIS AND QUANTITATIVE-EVALUATION OF SECUNDUM-TYPE ATRIAL SEPTAL-DEFECT BY TRANSESOPHAGEAL DOPPLER ECHOCARDIOGRAPHY
    MORIMOTO, K
    MATSUZAKI, M
    TOHMA, Y
    ONO, S
    TANAKA, N
    MICHISHIGE, H
    MURATA, K
    ANNO, Y
    KUSUKAWA, R
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (01) : 85 - 91
  • [17] DOPPLER COLOR-FLOW IMAGING ASSESSMENT OF SHUNT SIZE IN ATRIAL SEPTAL-DEFECT
    POLLICK, C
    SULLIVAN, H
    CUJEC, B
    WILANSKY, S
    [J]. CIRCULATION, 1988, 78 (03) : 522 - 528
  • [18] RELATIONSHIP OF ECHOCARDIOGRAPHIC, SHUNT FLOW, AND ANGIOGRAPHIC SIZE TO THE STRETCHED DIAMETER OF THE ATRIAL SEPTAL-DEFECT
    RAO, PS
    LANGHOUGH, R
    [J]. AMERICAN HEART JOURNAL, 1991, 122 (02) : 505 - 508
  • [19] ECHOCARDIOGRAPHIC ESTIMATION OF BALLOON-STRETCHED DIAMETER OF SECUNDUM ATRIAL SEPTAL-DEFECT FOR TRANSCATHETER OCCLUSION
    RAO, PS
    LANGHOUGH, R
    BEEKMAN, RH
    LLOYD, TR
    SIDERIS, EB
    [J]. AMERICAN HEART JOURNAL, 1992, 124 (01) : 172 - 175
  • [20] ECHOCARDIOGRAPHIC PREDICTORS OF SUCCESS OF CATHETER CLOSURE OF ATRIAL SEPTAL-DEFECT WITH THE BUTTONED DEVICE
    REDDY, SCB
    RAO, PS
    EWENKO, J
    KOSCIK, R
    WILSON, AD
    [J]. AMERICAN HEART JOURNAL, 1995, 129 (01) : 76 - 82